Characterization of Polylactic Acid–Polyglycolic Acid Composites for Cartilage Tissue Engineering
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The objective of this study was to determine the effects of scaffold composition on the physical properties, adhesion, and growth of bovine articular chondrocytes on polylactic acid (PLA)/polyglycolic acid (PGA) composites. Nonwoven meshes of PGA were coated with PLA, using a solvent evaporation technique that resulted in composites with fractional PLA contents ranging from 0 to 68%. The compressive modulus of scaffolds increased linearly with the addition of PLA, ranging from less than 1 kPa for PGA to approximately 20 kPa for scaffolds with 68% PLA content. The characteristic degradation time of these scaffolds also increased from approximately 5 days for 0% PLA to 45 days for 68% PLA. Addition of PLA decreased cell seeding efficiency from 48% for 0% PLA scaffolds to 27% for 68% PLA scaffolds. Cells seeded onto 27% PLA scaffolds increased 3-fold in number over 4 weeks in culture, whereas cells seeded onto 68% PLA increased only 2-fold in number. Scanning electron microscopy indicated that cells attached to PGA appeared flat with many small processes, whereas those attached to PLA were more rounded. These studies provide important information for the design of scaffolds for cartilage tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Engineering cell shape and function
Singhvi, R., Kumar, A., Lopez, G. P., Stephanopoulos, G. N., Wang, D. I. C., Whitesides, G. M., & Ingber, D. E. (1994) · Science · doi:10.1126/science.8171320 · Cited by 1,453 · cited 1×
“25 The current study highlights many important design considerations for the fabrication of scaffolds for tissue engineering using PLA and PGA.”
Fluorometric assay of DNA in cartilage explants using Hoechst 33258
Kim, Y.-J., Sah, R. L. Y., Doong, J.-Y. H., & Grodzinsky, A. J. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90532-5 · Cited by 1,357
Neocartilage formation in vitro and in vivo using cells cultured on synthetic biodegradable polymers
Freed, L. E., Marquis, J. C., Nohria, A., Emmanual, J., Mikos, A. G., & Langer, R. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270104 · Cited by 952
Cao, Y., Vacanti, J. P., Paige, K. T., Upton, J., & Vacanti, C. A. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199708000-00001 · Cited by 749 · cited 3×
“3,12 The objective of this study was to determine the ef-MORAN fects of scaffold composition on the physical properties of the material as well as the adhesion and growth kinetics of chondrocytes on seeded onto PLA/PGA composites.”
Vunjak‐Novakovic, G., Martin, I., Obradovic, B., Treppo, S., Grodzinsky, A. J., Langer, R., & Freed, L. E. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170119 · Cited by 743
Webb, K., Hlady, V., & Tresco, P. A. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980905)41:3<422::aid-jbm12>3.0.co;2-k · Cited by 689 · cited 1×
“24 Cells on scaffolds with high PGA content proliferated more rapidly, consistent with the idea that cell shape plays a role in regulating cell function.”
Biodegradable Polymer Scaffolds with Well-Defined Interconnected Spherical Pore Network
Ma, P. X., & Choi, J.-W. (2001) · Tissue Engineering · doi:10.1089/107632701300003269 · Cited by 620 · cited 1×
“21 The characteristic time constant for scaffold degradation increased linearly with PLA content, ranging from approximately 5 days for PGA scaffolds to 45 days for the materials with the highest PLA content (Fig.”
Replacement of an Avulsed Phalanx with Tissue-Engineered Bone
Vacanti, C. A., Bonassar, L. J., Vacanti, M. P., & Shufflebarger, J. (2001) · New England Journal of Medicine · doi:10.1056/nejm200105173442004 · Cited by 307
Self-citationFrank, E. H., & Grodzinsky, A. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90282-x · Cited by 301
Injection molding of chondrocyte/alginate constructs in the shape of facial implants
Chang, S. C. N., Rowley, J. A., Tobias, G., Genes, N. G., Roy, A. K., Mooney, D. J., Vacanti, C. A., & Bonassar, L. J. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20010615)55:4<503::aid-jbm1043>3.0.co;2-s · Cited by 298 · cited 1×
“3 Other techniques for producing cartilage in specific shapes, such as injection molding methods using hydrogens, 14 also tend to produce constructs that are initially weak mechanically.”
Self-citation
Cited by
Vepari, C., & Kaplan, D. L. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.013 · Cited by 2,561
Biocompatibility of hydrogel-based scaffolds for tissue engineering applications
Naahidi, S., Jafari, M., Logan, M., Wang, Y., Yuan, Y., Bae, H., Dixon, B., & Chen, P. (2017) · Biotechnology Advances · doi:10.1016/j.biotechadv.2017.05.006 · Cited by 907
Green composites: a review of material attributes and complementary applications
Dicker, M. P. M., Duckworth, P. F., Baker, A. B., Francois, G., Hazzard, M. K., & Weaver, P. M. (2014) · Composites Part A: Applied Science and Manufacturing · doi:10.1016/j.compositesa.2013.10.014 · Cited by 650
Multifunctional nanostructured PLA materials for packaging and tissue engineering
Armentano, I., Bitinis, N., Fortunati, E., Mattioli, S., Rescignano, N., Verdejo, R., Lopez-Manchado, M. A., & Kenny, J. M. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.05.010 · Cited by 645
Poly(Lactic Acid)-Based Biomaterials: Synthesis, Modification and Applications
Xiao, L., Wang, B., Yang, G., & Gauthier, M. (2012) · Biomedical Science, Engineering and Technology · doi:10.5772/23927 · Cited by 277
Directing Stem Cell Differentiation into the Chondrogenic Lineage In Vitro
Heng, B. C., Cao, T., & Lee, E. H. (2004) · STEM CELLS · doi:10.1634/stemcells.2004-0062 · Cited by 254
A review on synthesis and biomedical applications of polyglycolic acid
Budak, K., Sogut, O., & Aydemir Sezer, U. (2020) · Journal of Polymer Research · doi:10.1007/s10965-020-02187-1 · Cited by 251
Rahmani Del Bakhshayesh, A., Annabi, N., Khalilov, R., Akbarzadeh, A., Samiei, M., Alizadeh, E., Alizadeh-Ghodsi, M., Davaran, S., & Montaseri, A. (2018) · Artificial Cells, Nanomedicine, and Biotechnology · doi:10.1080/21691401.2017.1349778 · Cited by 250
Mizuno, H., Roy, A. K., Vacanti, C. A., Kojima, K., Ueda, M., & Bonassar, L. J. (2004) · Spine · doi:10.1097/01.brs.0000128264.46510.27 · Cited by 238
Self-citationBiodendrimer-Based Hydrogel Scaffolds for Cartilage Tissue Repair
Söntjens, S. H. M., Nettles, D. L., Carnahan, M. A., Setton, L. A., & Grinstaff, M. W. (2006) · Biomacromolecules · doi:10.1021/bm050663e · Cited by 230
An in situ forming collagen–PEG hydrogel for tissue regeneration
Sargeant, T. D., Desai, A. P., Banerjee, S., Agawu, A., & Stopek, J. B. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.07.028 · Cited by 186
“poly(lactic-co-glycolic acid) [37–40] and poly(vinyl alcohol) [41,42].”
Saroia, J., Yanen, W., Wei, Q., Zhang, K., Lu, T., & Zhang, B. (2018) · Bio-Design and Manufacturing · doi:10.1007/s42242-018-0029-7 · Cited by 170
The Tissue-Engineered Auricle: Past, Present, and Future
Bichara, D. A., O'Sullivan, N.-A., Pomerantseva, I., Zhao, X., Sundback, C. A., Vacanti, J. P., & Randolph, M. A. (2012) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0326 · Cited by 169
Metadata
- Authors
- Moran, J. M., Pazzano, D., & Bonassar, L. J.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2003-02
- Volume
- 9
- Issue
- 1
- Pages
- 63-70
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2174866962
- Cited by
- 170
- References
- 26
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.