Review: Practical Issues in Intravitreal Drug Delivery
The DOI matches its Crossref record.
Abstract
The delivery of drugs to the retina from solution or from prolonged release forms is considered in terms of pharmacokinetics, interference with vision, and toxicity and safety. It is concluded that visual loss will be the limiting factor in determining the useful life of a drug administered as a microdispersion. Because microparticles can be lost from the vitreous by diffusion, a condensed depot of drug can give a greater lifetime. However, it needs to be anchored outside the visual pathway which requires an intraocular operative procedure. Attaching a reservoir to the external sclera with a diffusion-controlled entry through a tube to the vitreous is suggested as having more flexibility than other systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A comprehensive insight on ocular pharmacokinetics
Agrahari, V., Mandal, A., Agrahari, V., Trinh, H. M., Joseph, M., Ray, A., Hadji, H., Mitra, R., Pal, D., & Mitra, A. K. (2016) · Drug Delivery and Translational Research · doi:10.1007/s13346-016-0339-2 · Cited by 462
Topical and systemic drug delivery to the posterior segments
HUGHES, P., OLEJNIK, O., CHANGLIN, J., & WILSON, C. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.09.004 · Cited by 400
Varela-Fernández, R., Díaz-Tomé, V., Luaces-Rodríguez, A., Conde-Penedo, A., García-Otero, X., Luzardo-Álvarez, A., Fernández-Ferreiro, A., & Otero-Espinar, F. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12030269 · Cited by 354
Drug delivery to the posterior segment of the eye
Thrimawithana, T. R., Young, S., Bunt, C. R., Green, C., & Alany, R. G. (2011) · Drug Discovery Today · doi:10.1016/j.drudis.2010.12.004 · Cited by 335
Ghate, D., & Edelhauser, H. F. (2006) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.3.2.275 · Cited by 329
Coated Microneedles for Drug Delivery to the Eye
Jiang, J., Gill, H. S., Ghate, D., McCarey, B. E., Patel, S. R., Edelhauser, H. F., & Prausnitz, M. R. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0066 · Cited by 286
Periocular routes for retinal drug delivery
Raghava, S., Hammond, M., & Kompella, U. B. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.99 · Cited by 257
Drug delivery to the retina: challenges and opportunities
Duvvuri, S., Majumdar, S., & Mitra, A. K. (2003) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.3.1.45 · Cited by 249
“Administration of particulate substances carries the risk of infection and blurred vision [36].”
BackgroundSubrizi, A., del Amo, E. M., Korzhikov-Vlakh, V., Tennikova, T., Ruponen, M., & Urtti, A. (2019) · Drug Discovery Today · doi:10.1016/j.drudis.2019.02.001 · Cited by 239
del Amo, E. M., & Urtti, A. (2015) · Experimental Eye Research · doi:10.1016/j.exer.2015.05.003 · Cited by 231
“In humans, the vitreous becomes more liquefied and less homogenous with the age, and this is associated with increased convective flow in the vitreal cavity (Maurice, 2001; Missel, 2012).”
BackgroundVitreous Substitutes: A Comprehensive Review
Kleinberg, T. T., Tzekov, R. T., Stein, L., Ravi, N., & Kaushal, S. (2011) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2010.09.001 · Cited by 223
“delivery devices, which has been demonstrated several times.(47,60,96,129,208)”
BackgroundNovel approaches to retinal drug delivery
Janoria, K. G., Gunda, S., Boddu, S. H., & Mitra, A. K. (2007) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.4.4.371 · Cited by 213
“Elimination from the vitreous is primarily governed by a first-order rate process [62] .”
BackgroundAmrite, A. C., & Kompella, U. B. (2005) · Journal of Pharmacy and Pharmacology · doi:10.1211/jpp.57.12.0005 · Cited by 212
“However, intravitreal particulate systems can likely interfere with vision (Maurice 2001) and potentially induce proliferative retinal disorders (Algvere & Martini 1985, 1986; Algvere et al 1988; Martini 1992).”
BackgroundXu, L., Lu, T., Tuomi, L., Jumbe, N., Lu, J., Eppler, S., Kuebler, P., Damico-Beyer, L. A., & Joshi, A. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-10260 · Cited by 201
Chang-Lin, J.-E., Burke, J. A., Peng, Q., Lin, T., Orilla, W. C., Ghosn, C. R., Zhang, K.-M., Kuppermann, B. D., Robinson, M. R., Whitcup, S. M., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6387 · Cited by 197
Akhtar, N., Singh, V., Yusuf, M., & Khan, R. A. (2020) · Biomedical Engineering / Biomedizinische Technik · doi:10.1515/bmt-2019-0019 · Cited by 193
“They also been used to effectively deliver small molecules, nanoparticles, fluid extractions and macromolecular entities such as antigens and proteins [172], LMW heparins [4, 173], insulin [174] and some vaccines [175].”
MethodDrug Delivery to the Eye: What Benefits do Nanocarriers offer?
Joseph, R. R., & Venkatraman, S. S. (2017) · Nanomedicine · doi:10.2217/nnm-2016-0379 · Cited by 192
Nanotherapy for posterior eye diseases
Kaur, I. P., & Kakkar, S. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.031 · Cited by 175
Polymer-based carriers for ophthalmic drug delivery
Imperiale, J. C., Acosta, G. B., & Sosnik, A. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2018.06.031 · Cited by 175
MYLES, M., NEUMANN, D., & HILL, J. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.08.006 · Cited by 171
Minimally invasive microneedles for ocular drug delivery
Thakur Singh, R. R., Tekko, I., McAvoy, K., McMillan, H., Jones, D., & Donnelly, R. F. (2017) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2016.1218460 · Cited by 171
Xu, M., Fan, R., Fan, X., Shao, Y., & Li, X. (2022) · Drug Design, Development and Therapy · doi:10.2147/dddt.s383101 · Cited by 111
“In addition, the drug may have an adverse impact on other organs.(92) When using transscleral administration, the drug diffuses through the sclera and circulates to the target tissue of the posterior segment of the eye through the subconjunctival and retrobulbar area, near the posterior sclera or posterior Tenon capsu…”
BackgroundLi, Q., Lai, K. L., Chan, P. S., Leung, S. C., Li, H. Y., Fang, Y., To, K. K. W., Choi, C. H. J., Gao, Q. Y., & Lee, T. W. Y. (2016) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2015.12.053 · Cited by 67
Use of rabbit eyes in pharmacokinetic studies of intraocular drugs
Ahn, S. J., Hong, H. K., Na, Y. M., Park, S. J., Ahn, J., Oh, J., Chung, J. Y., Park, K. H., & Woo, S. J. (2016) · Journal of Visualized Experiments · doi:10.3791/53878 · Cited by 60
Nanoparticulate drug delivery to the retina
Li, Q., Weng, J., Wong, S. N., Thomas Lee, W. Y., & Chow, S. F. (2021) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.0c00224 · Cited by 59
Li, Q., Qian, X., Li, H. Y., Lai, K. L., Gao, Q., & Lee, W. Y. T. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120226 · Cited by 26
Metadata
- Authors
- Maurice, D.
- Venue
- Journal of Ocular Pharmacology and Therapeutics
- Publisher
- SAGE Publications
- Published
- 2001-08
- Volume
- 17
- Issue
- 4
- Pages
- 393-401
- ISSN
- 1080-7683 (ISSN-L)
- 1557-7732
- OpenAlex
- W2043928656
- Cited by
- 150
- References
- 0
- FWCI
- 1.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.