Oxygen Effects on Glucose Measurements with a Reference Analyzer and Three Handheld Meters
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Oxygen may affect glucose meter and reference analyzer measurements. We evaluated the effects of changes in blood oxygen tension (Po2) on Accu-Chek Comfort Curve (Roche Diagnostics, Indianapolis, IN),™ Precision G,™ (Abbott Laboratories, Bedford, MA) and One Touch II® (Lifescan, Milpitas, CA) glucose meter measurements, and on Yellow Springs Instruments (YSI) (Yellow Springs, OH) reference analyzer measurements. Venous blood drawn from healthy volunteers was adjusted to three glucose levels of 80, 200, and 400 mg/dL, each tonometered with six different Po2 levels (40, 80, 160, 240, 320, and 400 torr). To quantitate oxygen effects on reference analyzer measurements, glucose differences between test sample (Po changed) and control (Po 80 torr) were calculated (YSItest-YSIcontrol). The threshold for determination of oxygen effects was ± 2 SD, where 2 SD was from YSI between-day precision evaluated with aqueous controls. To quantitate oxygen effects on glucose meter measurements, paired-differences between glucose meter and reference analyzer measurements were calculated (Meter-YSI). Error tolerances for determination of oxygen effects were (a) within ± 15 mg/dL of reference measurement at glucose levels ≤100 mg/dL, and (b) within ± 15% of reference measurement at glucose levels >100 mg/dL. All differences for the reference analyzer measurements were within ± 2 SD ranges. Increases in Po2 lowered Precision G measurements. Differences exceeding the error tolerances ( ± 15 mg/dL or ± 15%) were mainly at Po2 levels >100 torr. Glucose differences for the Accu-Chek Comfort Curve and One Touch II were within the error tolerances. Changes in Po2 do not affect glucose measurements with the YSI reference analyzer, Accu-Chek Comfort Curve, and One Touch meter systems. High blood Po2 levels (>100 torr) significantly decrease Precision G measurements. We recommend that health care professionals understand oxygen effects and use oxygen-insensitive meter systems for point-of-care glucose testing when patients are on oxygen ventilation or critically ill.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tang, Z., Lee, J. H., Louie, R. F., & Kost, G. J. (2000) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2000-124-1135-eodhlo · Cited by 293
Self-citation
Cited by
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
Glucose Measurement: Confounding Issues in Setting Targets for Inpatient Management
Dungan, K., Chapman, J., Braithwaite, S. S., & Buse, J. (2007) · Diabetes Care · doi:10.2337/dc06-1679 · Cited by 292
Freckmann, G., Schmid, C., Baumstark, A., Pleus, S., Link, M., & Haug, C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600510 · Cited by 237
The Accuracy of Point-of-Care Glucose Measurements
Rebel, A., Rice, M. A., & Fahy, B. G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600228 · Cited by 144
Hattemer, A., & Wardat, S. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818757550 · Cited by 8
Metadata
- Authors
- Tang, Z., Louie, R. F., Payes, M., Chang, K.-C. J., & Kost, G. J.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2000-10
- Volume
- 2
- Issue
- 3
- Pages
- 349-362
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2076721326
- Cited by
- 63
- References
- 1
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›