Clinical Evaluation of a Novel Interstitial Fluid Sensor System for Remote Continuous Alcohol Monitoring

Venugopal, Manju, Feuvrel, Kathryn E., Mongin, David, Bambot, Shabbir, Faupel, Mark, Panangadan, Anand, Talukder, Ashit, Pidva, Rishi·2008·IEEE Sensors Journal

Abstract

This study describes the functioning of a novel sensor that measures the alcohol concentration in the interstitial fluid (ISF) of a human subject. ISF is extracted using vacuum pressure from micropores on the stratum corneum layer of the skin. The pores are created by focusing a near infrared laser on a layer of black die attached to the skin. This poration procedure is essentially painless. Clinical studies show that the sensor readings are correlated with alcohol levels in blood and collected using a breathalyzer. Alcohol could be detected in the subject's ISF within 15 min of the first oral intake of alcohol. Tests in a laboratory setup show that the sensor exhibits a linear response to alcohol concentrations in the range 0%-0.2%. The sensor is minimally invasive and alcohol monitoring using the sensor was shown to continue even when the subject is asleep. The sensor is viable for approximately three days after skin poration. The sensor is interfaced to a wireless health monitoring system that transfers sensor data over existing wide-area networks such as the Internet and a cellular phone network to enable real-time remote monitoring of subjects.

Integrity signals

Registry

Crossref · 10.1109/jsen.2007.912544

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • ISF composition leads to reliable correlations between blood and ISF concentrations of many analytes, including electrolytes, metabolites, and proteins.

    “This function, and the associated ISF composition, lead to reliable correlations between the blood and ISF concentrations of many analytes, including electrolytes (e.g., sodium, phosphate, magnesium, potassium or calcium), metabolites (e.g., glucose, alcohol, lactate or cortisol) and proteins65-69.”

    From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [68]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Venugopal, M., Feuvrel, K. E., Mongin, D., Bambot, S., Faupel, M., Panangadan, A., Talukder, A., & Pidva, R.
Affiliations
  • Guided Therapeutics (United States) (US)
  • Children's Hospital Los Angeles (US)
Venue
IEEE Sensors Journal
Published
2008-01
Volume
8
Issue
1
Pages
71-80
ISSN
1530-437X (ISSN-L)
OpenAlex
W2122071975
Cited by
76
References
47
Citations by year
2026: 2 · 2025: 1 · 2024: 5 · 2023: 7 · 2022: 7 · 2021: 6 · 2020: 7 · 2019: 4 · 2018: 5 · 2017: 3 · 2016: 1 · 2015: 4 · 2014: 3 · 2013: 6 · 2012: 1
FWCI
2.87
Type
journal article
Language
en
Open access
closed
Locations
IEEE Sensors Journal (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
Keywords
interstitial fluid, alcohol monitoring, near-infrared laser, stratum corneum, minimally invasive sensing, wireless health monitoring, breathalyzer, alcohol detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review