The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Continuous Glucose Sensor Based on Wired Enzyme ™ Technology - Results from a 3-Day Trial in Patients with Type 1 Diabetes
Abstract
Wired Enzyme (Therasense, Alameda, CA) sensing technology for continuous measurement of in vivo glucose concentrations offers the benefits of (1). excellent sensor stability, (2). reduced susceptibility to variations of in vivo oxygen concentration, and (3). minimized response to common electroactive interferents. This study describes the response of 48 sensors (25 in the upper arm, 23 in the abdomen) implanted for 3 days in patients with Type 1 diabetes. Prospective calibration was performed using capillary blood; results were compared with venous plasma glucose values obtained at 15-min intervals. Ninety-eight percent of readings fell in the clinically accurate Clarke error grid zone A or clinically acceptable zone B. Choice of the site of the implanted sensor (upper arm vs. abdomen) or the capillary blood calibration site (arm vs. finger) did not affect system accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis: PENDRA: The Once and Future Noninvasive Continuous Glucose Monitoring Device?
Weinzimer, S. A. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/1520915041706018 · Cited by 37
Research works printed but not linked: 6
- 10.1056/NEJM199309303291401 · DOI · Paper page
- 10.1021/ac00103a015 · DOI
- Roe JN, 1998, Crit Rev Ther Drug Carrier Syst, 15, 199
- 10.1007/s002160051556 · DOI · Paper page
- 10.2337/diacare.24.7.1303 · DOI
- 10.1089/15209150252924058 · doi:10.1089/15209150252924058
Cited by
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Self-citationBiosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
Metadata
- Authors
- Feldman, B., Brazg, R., Schwartz, S., & Weinstein, R.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2003-10
- Volume
- 5
- Issue
- 5
- Pages
- 769-779
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1988037818
- Cited by
- 184
- References
- 1
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.liebertpub.com/nv/resources-tools/text-and-data-mining-policy/121/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Continuous Glucose Sensor Based on Wired Enzyme ™ Technology - Results from a 3-Day Trial in Patients with Type 1 Diabetes. https://app.cochat.ai/papers/10.1089/152091503322526978
- The paper
- Feldman, B., Brazg, R., Schwartz, S., & Weinstein, R. (2003). A Continuous Glucose Sensor Based on Wired Enzyme ™ Technology - Results from a 3-Day Trial in Patients with Type 1 Diabetes. Diabetes Technology & Therapeutics. https://doi.org/10.1089/152091503322526978
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.