A Continuous Glucose Sensor Based on Wired Enzyme ™ Technology - Results from a 3-Day Trial in Patients with Type 1 Diabetes
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Wired Enzyme (Therasense, Alameda, CA) sensing technology for continuous measurement of in vivo glucose concentrations offers the benefits of (1). excellent sensor stability, (2). reduced susceptibility to variations of in vivo oxygen concentration, and (3). minimized response to common electroactive interferents. This study describes the response of 48 sensors (25 in the upper arm, 23 in the abdomen) implanted for 3 days in patients with Type 1 diabetes. Prospective calibration was performed using capillary blood; results were compared with venous plasma glucose values obtained at 15-min intervals. Ninety-eight percent of readings fell in the clinically accurate Clarke error grid zone A or clinically acceptable zone B. Choice of the site of the implanted sensor (upper arm vs. abdomen) or the capillary blood calibration site (arm vs. finger) did not affect system accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Textbook of Clinical Chemistry.
(1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-508_6 · Cited by 1,227
Characterization of implantable biosensor membrane biofouling
Wisniewski, N., Moussy, F., & Reichert, W. M. (2000) · Fresenius' Journal of Analytical Chemistry · doi:10.1007/s002160051556 · Cited by 350
Evaluating the Accuracy of Continuous Glucose-Monitoring Sensors
Kovatchev, B. P., Gonder-Frederick, L. A., Cox, D. J., & Clarke, W. L. (2004) · Diabetes Care · doi:10.2337/diacare.27.8.1922 · Cited by 312
Csoeregi, E., Schmidtke, D. W., & Heller, A. (1995) · Analytical Chemistry · doi:10.1021/ac00103a015 · Cited by 129
On the parameters affecting the characteristics of the “wired” glucose oxidase anode
Mano, N., Mao, F., & Heller, A. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2004.08.014 · Cited by 120
Bloodless Glucose Measurements
Smoller, B. R., & Roe, J. N. (1998) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v15.i3.10 · Cited by 78
Risky Delay of Hypoglycemia Detection by Glucose Monitoring at the Arm
Jungheim, K., & Koschinsky, T. (2001) · Diabetes Care · doi:10.2337/diacare.24.7.1303-a · Cited by 62
Stout, P. J., Racchini, J. R., & Hilgers, M. E. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.635 · Cited by 59
High Incidence of Maternal Transmission of Diabetes in Obese Uruguayan Children
Pisabarro, R., Recalde, A., & Chaftare, Y. (2001) · Diabetes Care · doi:10.2337/diacare.24.7.1303 · Cited by 38
Research works printed but not linked: 1
- Roe JN, 1998, Crit Rev Ther Drug Carrier Syst, 15, 199
Cited by
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Self-citationKlonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
Fully Integrated Artificial Pancreas in Type 1 Diabetes
Breton, M., Farret, A., Bruttomesso, D., Anderson, S., Magni, L., Patek, S., Dalla Man, C., Place, J., Demartini, S., Del Favero, S., et al. (2012) · Diabetes · doi:10.2337/db11-1445 · Cited by 315
Evaluating the Accuracy of Continuous Glucose-Monitoring Sensors
Kovatchev, B. P., Gonder-Frederick, L. A., Cox, D. J., & Clarke, W. L. (2004) · Diabetes Care · doi:10.2337/diacare.27.8.1922 · Cited by 312
“T he premise behind increasing research and industrial efforts on the development of continuous glucose sensors (CGSs) is that the accurate assessment of blood glucose (BG) dynamics is a valuable tool for both everyday maintenance of diabetes and long-term effectiveness of glycemic control (1,2).”
BackgroundLee, I., Probst, D., Klonoff, D., & Sode, K. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113054 · Cited by 288
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Electrochemistry in Diabetes Management
Heller, A., & Feldman, B. (2010) · Accounts of Chemical Research · doi:10.1021/ar9002015 · Cited by 255
Self-citationAssessing Sensor Accuracy for Non-Adjunct Use of Continuous Glucose Monitoring
Kovatchev, B. P., Patek, S. D., Ortiz, E. A., & Breton, M. D. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0272 · Cited by 234
Accuracy of the 5-Day FreeStyle Navigator Continuous Glucose Monitoring System
Weinstein, R. L., Schwartz, S. L., Brazg, R. L., Bugler, J. R., Peyser, T. A., & McGarraugh, G. V. (2007) · Diabetes Care · doi:10.2337/dc06-1602 · Cited by 228
“The glucose measurement is made using the Wired Enzyme method, a modified glucose oxidase enzymatic reaction including an osmium mediator covalently bound to the supporting polymer matrix (14).”
MethodSelf-citationBiosensors and bioelectrochemistry
Murphy, L. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.02.023 · Cited by 225
Technology behind commercial devices for blood glucose monitoring in diabetes management: A review
Vashist, S. K., Zheng, D., Al-Rubeaan, K., Luong, J. H. T., & Sheu, F.-S. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.07.024 · Cited by 209
In vivo glucose monitoring: the clinical reality and the promise
Pickup, J. C., Hussain, F., Evans, N. D., & Sachedina, N. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.08.016 · Cited by 203
Glycemic Monitoring and Management in Advanced Chronic Kidney Disease
Galindo, R. J., Beck, R. W., Scioscia, M. F., Umpierrez, G. E., & Tuttle, K. R. (2020) · Endocrine Reviews · doi:10.1210/endrev/bnaa017 · Cited by 202
Kovatchev, B. P., Clarke, W. L., Breton, M., Brayman, K., & McCall, A. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.849 · Cited by 201
Delays in Minimally Invasive Continuous Glucose Monitoring Devices: A Review of Current Technology
Keenan, D. B., Mastrototaro, J. J., Voskanyan, G., & Steil, G. M. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300528 · Cited by 198
Koschwanez, H. E., & Reichert, W. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.034 · Cited by 181
Ribet, F., Stemme, G., & Roxhed, N. (2018) · Biomedical Microdevices · doi:10.1007/s10544-018-0349-6 · Cited by 181
“Moreover, several commercial CGM devices have been presented (Csöregi et al. 1995; Feldman et al. 2003; Heller and Feldman 2008; Rodbard 2016; Yoo and Lee 2010) and released to the market since the early 2000s.”
Potentially implantable miniature batteries
Heller, A. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0326-4 · Cited by 181
Wearable and implantable devices for drug delivery: Applications and challenges
Kar, A., Ahamad, N., Dewani, M., Awasthi, L., Patil, R., & Banerjee, R. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121435 · Cited by 179
Continuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176
“Since then, CGM sensors have been constantly improved by adding new features: the real-time visualization of glucose concentration value and its trend [2], the generation of acoustic and visual alerts when settable hypoglycemic and hyperglycemic thresholds are overcome [3], the increase in”
BackgroundGalindo, R. J., Aleppo, G., Klonoff, D. C., Spanakis, E. K., Agarwal, S., Vellanki, P., Olson, D. E., Umpierrez, G. E., Davis, G. M., & Pasquel, F. J. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820932903 · Cited by 155
“22 Ascorbic acid may falsely elevate sensor glucose readings, while aspirin may slightly lower glucose readings with FreeStyle Libre.”
Caduff, A., Dewarrat, F., Talary, M., Stalder, G., Heinemann, L., & Feldman, Y. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.031 · Cited by 155
Glycemic Characteristics in Continuously Monitored Patients With Type 1 and Type 2 Diabetes
Bode, B. W., Schwartz, S., Stubbs, H. A., & Block, J. E. (2005) · Diabetes Care · doi:10.2337/diacare.28.10.2361 · Cited by 137
Self-citationRealistic Expectations and Practical Use of Continuous Glucose Monitoring for the Endocrinologist
Hirsch, I. B. (2009) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-2625 · Cited by 93
Freckmann, G., Eichenlaub, M., Waldenmaier, D., Pleus, S., Wehrstedt, S., Haug, C., Witthauer, L., Jendle, J., Hinzmann, R., Thomas, A., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231190941 · Cited by 86
A Century of Diabetes Technology: Signals, Models, and Artificial Pancreas Control
Kovatchev, B. (2019) · Trends in Endocrinology & Metabolism · doi:10.1016/j.tem.2019.04.008 · Cited by 80
Metabolic Biofouling of Glucose Sensors in Vivo : Role of Tissue Microhemorrhages
Klueh, U., Liu, Z., Feldman, B., Henning, T. P., Cho, B., Ouyang, T., & Kreutzer, D. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500313 · Cited by 63
Self-citationLimits to the Evaluation of the Accuracy of Continuous Glucose Monitoring Systems by Clinical Trials
Schrangl, P., Reiterer, F., Heinemann, L., Freckmann, G., & Del Re, L. (2018) · Biosensors · doi:10.3390/bios8020050 · Cited by 46
Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility
Cobelli, C., & Kovatchev, B. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231195081 · Cited by 46
Zheng, Y., Zhan, Z., Chen, Q., Chen, J., Luo, J., Cai, J., Zhou, Y., Chen, K., & Xie, W. (2024) · Advanced Science · doi:10.1002/advs.202405681 · Cited by 38
Analysis: PENDRA: The Once and Future Noninvasive Continuous Glucose Monitoring Device?
Weinzimer, S. A. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/1520915041706018 · Cited by 37
Metadata
- Authors
- Feldman, B., Brazg, R., Schwartz, S., & Weinstein, R.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2003-10
- Volume
- 5
- Issue
- 5
- Pages
- 769-779
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1988037818
- Cited by
- 184
- References
- 13
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.liebertpub.com/nv/resources-tools/text-and-data-mining-policy/121/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.