Alarms Based on Real-Time Sensor Glucose Values Alert Patients to Hypo- and Hyperglycemia: The Guardian Continuous Monitoring System
Abstract
The purposes of this study were to demonstrate the accuracy and effectiveness of the Guardian Continuous Monitoring System (Medtronic MiniMed, Northridge, California) and to demonstrate that the application of real-time alarms to continuous monitoring alerts users to hypo and hyperglycemia and reduces excursions in people with diabetes. A total of 71 subjects with type 1 diabetes, mean hemoglobin A1c of 7.6 +/- 1.1%, age 44.0 +/- 11.4 years, and duration of diabetes 23.6 +/- 10.6 years were enrolled in this two-period, randomized, multicenter study. Subjects were randomized into either an Alert group or a Control group. The accuracy of the Guardian was evaluated by treating the study data as a single-sample correlational design. Effectiveness of the Guardian alerts was evaluated by comparing the Alert group with the Control group. The mean (median) absolute relative error between home blood glucose meter readings and sensor values was 21.3% (17.3%), and the Guardian, on average, read 12.8 mg/dL below the concurrent home blood glucose meter readings. The hypoglycemia alert was able to distinguished glucose values < or =70 mg/dL with 67% sensitivity, 90% specificity, and 47% false alerts. The hyperglycemia alert showed a similar ability to detect sensor values > or =250 mg/dL with 63% sensitivity, 97% specificity, and 19% false alerts. The Alert group demonstrated a median decrease in the duration of hypoglycemic excursions (-27.8 min) that was significantly greater than the median decrease in the duration of hypoglycemic excursions in the Control group (-4.5 min) (P = 0.03). A marginally significant increase in the frequency of hyperglycemic excursions (P = 0.07) between Period 1 and Period 2 was accompanied by a decrease of 9.6 min in the duration of hyperglycemic excursions in the Alert group. Glucose measurements differ between blood samples taken from the finger and interstitial fluid, especially when levels are changing rapidly; however, these results demonstrate that the Guardian is reasonably accurate while performing continuous glucose monitoring. The subjects' responses to hypoglycemia alerts resulted in a significant reduction in the duration of hypoglycemic excursions; however, overtreating hypoglycemia may have resulted in a marginally significant increase in the frequency of hyperglycemic excursions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746
Bode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232
Self-citation
Cited by
(2007) · Endocrine Practice · doi:10.4158/ep.13.s1.1 · Cited by 699
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“These methods have rapidly evolved from a concept [238] to implementation in CGM devices, such as the GuardianRT (Medtronic, Norhtridge, CA) [239] and the Freestyle Navigator (Abbott Diabetes Care, Alameda, CA) [178].”
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Metadata
- Authors
- Bode, B., Gross, K., Rikalo, N., Schwartz, S., Wahl, T., Page, C., Gross, T., & Mastrototaro, J.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2004-04
- Volume
- 6
- Issue
- 2
- Pages
- 105-113
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2177137510
- Cited by
- 190
- References
- 2
- FWCI
- 7.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Alarms Based on Real-Time Sensor Glucose Values Alert Patients to Hypo- and Hyperglycemia: The Guardian Continuous Monitoring System. https://app.cochat.ai/papers/10.1089/152091504773731285
- The paper
- Bode, B., Gross, K., Rikalo, N., Schwartz, S., Wahl, T., Page, C., Gross, T., & Mastrototaro, J. (2004). Alarms Based on Real-Time Sensor Glucose Values Alert Patients to Hypo- and Hyperglycemia: The Guardian Continuous Monitoring System. Diabetes Technology & Therapeutics. https://doi.org/10.1089/152091504773731285
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.