Alarms Based on Real-Time Sensor Glucose Values Alert Patients to Hypo- and Hyperglycemia: The Guardian Continuous Monitoring System
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The purposes of this study were to demonstrate the accuracy and effectiveness of the Guardian Continuous Monitoring System (Medtronic MiniMed, Northridge, California) and to demonstrate that the application of real-time alarms to continuous monitoring alerts users to hypo and hyperglycemia and reduces excursions in people with diabetes. A total of 71 subjects with type 1 diabetes, mean hemoglobin A1c of 7.6 +/- 1.1%, age 44.0 +/- 11.4 years, and duration of diabetes 23.6 +/- 10.6 years were enrolled in this two-period, randomized, multicenter study. Subjects were randomized into either an Alert group or a Control group. The accuracy of the Guardian was evaluated by treating the study data as a single-sample correlational design. Effectiveness of the Guardian alerts was evaluated by comparing the Alert group with the Control group. The mean (median) absolute relative error between home blood glucose meter readings and sensor values was 21.3% (17.3%), and the Guardian, on average, read 12.8 mg/dL below the concurrent home blood glucose meter readings. The hypoglycemia alert was able to distinguished glucose values < or =70 mg/dL with 67% sensitivity, 90% specificity, and 47% false alerts. The hyperglycemia alert showed a similar ability to detect sensor values > or =250 mg/dL with 63% sensitivity, 97% specificity, and 19% false alerts. The Alert group demonstrated a median decrease in the duration of hypoglycemic excursions (-27.8 min) that was significantly greater than the median decrease in the duration of hypoglycemic excursions in the Control group (-4.5 min) (P = 0.03). A marginally significant increase in the frequency of hyperglycemic excursions (P = 0.07) between Period 1 and Period 2 was accompanied by a decrease of 9.6 min in the duration of hyperglycemic excursions in the Alert group. Glucose measurements differ between blood samples taken from the finger and interstitial fluid, especially when levels are changing rapidly; however, these results demonstrate that the Guardian is reasonably accurate while performing continuous glucose monitoring. The subjects' responses to hypoglycemia alerts resulted in a significant reduction in the duration of hypoglycemic excursions; however, overtreating hypoglycemia may have resulted in a marginally significant increase in the frequency of hyperglycemic excursions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746 · cited 1×
“Hypoglycemia is a frightening and some-times dangerous acute complication of tight glycemic control, 1,15,16 and experience with the CGMS has shown that people with diabetes often over-treat hypoglycemia, resulting in hyperglycemic excursions.”
Limitations of Conventional Methods of Self-Monitoring of Blood Glucose
Boland, E., Monsod, T., Delucia, M., Brandt, C. A., Fernando, S., & Tamborlane, W. V. (2001) · Diabetes Care · doi:10.2337/diacare.24.11.1858 · Cited by 423
The MiniMed Continuous Glucose Monitoring System
Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214078 · Cited by 393
Self-citationRebrin, K., Steil, G. M., van Antwerp, W. P., & Mastrototaro, J. J. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.277.3.e561 · Cited by 366 · cited 1×
“13 The effectiveness of the real-time hypo-and hyperglycemia alerts produced by the Guardian were evaluated by calculating sensitivity and specificity and producing ROC curves.”
Self-citationBode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232 · cited 1×
“3,7,8 The application of real-time alarms to continuous glucose monitoring would alert users to predetermined thresholds of impending hypo-and hyperglycemia, allowing immediate corrective action that may preempt severe events.”
Self-citationA Pilot Study of the Continuous Glucose Monitoring System
Kaufman, F. R., Gibson, L. C., Halvorson, M., Carpenter, S., Fisher, L. K., & Pitukcheewanont, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2030 · Cited by 224
Continuous Subcutaneous Glucose Monitoring in Children With Type 1 Diabetes
Chase, H. P., Kim, L. M., Owen, S. L., MacKenzie, T. A., Klingensmith, G. J., Murtfeldt, R., & Garg, S. K. (2001) · Pediatrics · doi:10.1542/peds.107.2.222 · Cited by 194
Is blood glucose predictable from previous values? A solicitation for data.
Bremer, T. M., & Gough, D. A. (1999) · Diabetes · doi:10.2337/diabetes.48.3.445 · Cited by 160
Cox, D. J., Penberthy, J. K., Zrebiec, J., Weinger, K., Aikens, J. E., Frier, B., Stetson, B., DeGroot, M., Trief, P., Schaechinger, H., et al. (2003) · Diabetes Care · doi:10.2337/diacare.26.8.2329 · Cited by 150 · cited 1×
“Hypoglycemia is a frightening and some-times dangerous acute complication of tight glycemic control, 1,15,16 and experience with the CGMS has shown that people with diabetes often over-treat hypoglycemia, resulting in hyperglycemic excursions.”
Cited by
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
(2007) · Endocrine Practice · doi:10.4158/ep.13.s1.1 · Cited by 699
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“These methods have rapidly evolved from a concept [238] to implementation in CGM devices, such as the GuardianRT (Medtronic, Norhtridge, CA) [239] and the Freestyle Navigator (Abbott Diabetes Care, Alameda, CA) [178].”
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
“Percentage of error for individual sensors have been reported as 17% for the Guardian (cid:1) REAL-Time (Minimed, Northridge, CA), 51 11–16% for DexCom STS (DexCom, San Diego, CA), 52,53 and 12–14% for the Navigator (Abbott Diabetes Care, Alameda, CA).”
Sparacino, G., Zanderigo, F., Corazza, S., Maran, A., Facchinetti, A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889774 · Cited by 338
The Evidence for Medical Nutrition Therapy for Type 1 and Type 2 Diabetes in Adults
Franz, M. J., Powers, M. A., Leontos, C., Holzmeister, L. A., Kulkarni, K., Monk, A., Wedel, N., & Gradwell, E. (2010) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2010.09.014 · Cited by 306
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Continuous Glucose Monitoring Systems: A Review
Vashist, S. (2013) · Diagnostics · doi:10.3390/diagnostics3040385 · Cited by 261
Yoo, H. J., An, H. G., Park, S. Y., Ryu, O. H., Kim, H. Y., Seo, J. A., Hong, E. G., Shin, D. H., Kim, Y. H., Kim, S. G., et al. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.06.015 · Cited by 244
Concurrent delivery of dexamethasone and VEGF for localized inflammation control and angiogenesis
Patil, S. D., Papadmitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.013 · Cited by 230
O’Connell, M. A., Donath, S., O’Neal, D. N., Colman, P. G., Ambler, G. R., Jones, T. W., Davis, E. A., & Cameron, F. J. (2009) · Diabetologia · doi:10.1007/s00125-009-1365-0 · Cited by 211
“Studies assessing their use have shown improvement in HbA1c [7–11], increased time spent in the target glucose range [11, 12] and fewer hypo- and hyperglycaemic excursions [9, 13], suggesting the potential for important clinical benefits.”
BackgroundMechanisms of hypoglycemia unawareness and implications in diabetic patients
Martín-Timón, I. (2015) · World Journal of Diabetes · doi:10.4239/wjd.v6.i7.912 · Cited by 204
Delays in Minimally Invasive Continuous Glucose Monitoring Devices: A Review of Current Technology
Keenan, D. B., Mastrototaro, J. J., Voskanyan, G., & Steil, G. M. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300528 · Cited by 198
Self-citationNeural Network-Based Real-Time Prediction of Glucose in Patients with Insulin-Dependent Diabetes
Pappada, S. M., Cameron, B. D., Rosman, P. M., Bourey, R. E., Papadimos, T. J., Olorunto, W., & Borst, M. J. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0104 · Cited by 182
Zecchin, C., Facchinetti, A., Sparacino, G., De Nicolao, G., & Cobelli, C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2188893 · Cited by 178
Continuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176
“Since then, CGM sensors have been constantly improved by adding new features: the real-time visualization of glucose concentration value and its trend [2], the generation of acoustic and visual alerts when settable hypoglycemic and hyperglycemic thresholds are overcome [3], the increase in”
BackgroundOptimal sampling intervals to assess long-term glycemic control using continuous glucose monitoring
Xing, D., Kollman, C., Beck, R. W., Tamborlane, W. V., Laffel, L., Buckingham, B. A., Wilson, D. M., Weinzimer, S., Fiallo-Scharer, R., & Ruedy for the Juvenile Diabetes Research Foundation Continuo, K. J. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0156 · Cited by 131
Freckmann, G., Eichenlaub, M., Waldenmaier, D., Pleus, S., Wehrstedt, S., Haug, C., Witthauer, L., Jendle, J., Hinzmann, R., Thomas, A., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231190941 · Cited by 86
Joubert, M., & Reznik, Y. (2012) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2011.12.010 · Cited by 70
“[11] Bode B, Gross K, Rikalo N, Schwartz S, Wahl T, Page C, et al.”
BackgroundDavis, S. N., Horton, E. S., Battelino, T., Rubin, R. R., Schulman, K. A., & Tamborlane, W. V. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0145 · Cited by 40
Meng, R., Gu, T., Yang, F., Liu, J., Sun, Q., & Zhu, D. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01171-2 · Cited by 11
Metadata
- Authors
- Bode, B., Gross, K., Rikalo, N., Schwartz, S., Wahl, T., Page, C., Gross, T., & Mastrototaro, J.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2004-04
- Volume
- 6
- Issue
- 2
- Pages
- 105-113
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2177137510
- Cited by
- 190
- References
- 15
- FWCI
- 7.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.