Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 449

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Bioluminescent Assays for High-Throughput Screening

Fan, Frank, Wood, Keith V.·2007·ASSAY and Drug Development Technologies

Abstract

In the development of high throughput screening (HTS) as a central paradigm of drug discovery, fluorescence has generally been adopted as the favored methodology. Nevertheless, luminescence has maintained a prominent position among certain assay formats, most notably genetic reporters. Recently, there has been growing partiality for luminescent assays across a wider range of applications due to their sensitivity, broad linearity, and robustness to library compounds and complex biological samples. This trend has been fostered by the development of several new assay designs for diverse targets such as kinases, cytochrome p450s, proteases, apoptosis, and cytotoxicity. This review addresses recent progress made in the use of bioluminescent assays for HTS, highlighting new detection capabilities brought about by engineering luciferase genes, enzymes, and substrates. In genetic reporter applications, modifications to the luciferase genes have improved assay sensitivity by substantially increasing expression efficiency and enhanced response dynamics by reducing expression lifetime. The performance of assays based on detection of ATP and luciferin has been enhanced by modifications to the luciferase enzyme that increase its chemical and physical stability. Detection of ATP allows rapid analysis of cell metabolism and enzymatic processes coupled to ATP metabolism. Because luciferins are not naturally associated with mammalian physiology, assays for luciferin detection utilize synthetic derivatives designed to yield luminescence only when coupled with specific target enzymes. Finally, new methods for modulating the specific activity of luciferases are leading to the development of intracellular biosensors for dynamic detection of physiological processes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/adt.2006.053

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 449

Metadata

Authors
Fan, F., & Wood, K. V.
Venue
ASSAY and Drug Development Technologies
Published
2007-02
Volume
5
Issue
1
Pages
127-136
ISSN
  • 1540-658X (ISSN-L)
  • 1557-8127
OpenAlex
W2042852723
Cited by
449
References
31
FWCI
9.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bioluminescent Assays for High-Throughput Screening. https://app.cochat.ai/papers/10.1089/adt.2006.053
The paper
Fan, F., & Wood, K. V. (2007). Bioluminescent Assays for High-Throughput Screening. ASSAY and Drug Development Technologies. https://doi.org/10.1089/adt.2006.053

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.