Optimal Insulin Pump Dosing and Postprandial Glycemia Following a Pizza Meal Using the Continuous Glucose Monitoring System
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
BACKGROUND: We attempted to identify an optimal insulin pump meal bolus by comparing postprandial sensor glucose values following three methods of insulin pump meal bolusing for a consistent pizza meal. RESEARCH DESIGN AND METHODS: Twenty-four patients with type 1 diabetes participated in a study to compare postprandial glucose values following three meal bolus regimens for a consistent evening pizza meal. Each participant utilized the following insulin lispro regimens on consecutive evenings, and glucose values were tracked by the Continuous Glucose Monitoring System (CGMS, Medtronic MiniMed, Northridge, CA): (a) single-wave bolus (100% of insulin given immediately); (b) 4-h dual-wave bolus (50% of insulin given immediately and 50% given over a 4-h period); and (c) 8-h dual-wave bolus (50% of insulin given immediately and 50% given over a 8-h period). Total insulin bolus amount was kept constant for each pizza meal. RESULTS: Divergence in blood glucose among the regimens was greatest at 8-12 h. The 8-h dual-wave bolus provided the best glycemic control and lowest mean glucose values (singlewave bolus, 133 mg/dL; 4-h dual-wave bolus, 145 mg/dL; 8-h dual-wave bolus, 104 mg/dL), leading to a difference in mean glucose of 29 mg/dL for the single-wave bolus versus the 8-h dual-wave bolus and 42 mg/dL for the 4-h dual-wave bolus versus the 8-h dual-wave bolus. The lower mean glucose in the 8-h dual-wave bolus was not associated with any increased incidence of hypoglycemia. CONCLUSIONS: Use of a dual-wave bolus extended over an 8-h period following a pizza meal provided significantly less postprandial hyperglycemia in the late postprandial period (8-12 h) with no increased risk of hypoglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glucose Tolerance and Cardiovascular Mortality: Comparison of Fasting and 2-Hour Diagnostic Criteria
(2001) · Archives of Internal Medicine · doi:10.1001/archinte.161.3.397 · Cited by 1,371 · cited 1×
“American College of Endocrinology 13 have recognized the importance of postprandial glucose (PPG) control as an important therapeutic goal given its relationship to the development 14–20 treatment strategy focused Northridge, measures.”
Hanefeld, M., Fischer, S., Julius, U., Schulze, J., Schwanebeck, U., Schmechel, H., Ziegelasch, H. J., & Lindner, J. (1996) · Diabetologia · doi:10.1007/s001250050617 · Cited by 873 · cited 1×
“American College of Endocrinology 13 have recognized the importance of postprandial glucose (PPG) control as an important therapeutic goal given its relationship to the development 14–20 treatment strategy focused Northridge, measures.”
de Veciana, M., Major, C. A., Morgan, M. A., Asrat, T., Toohey, J. S., Lien, J. M., & Evans, A. T. (1995) · New England Journal of Medicine · doi:10.1056/nejm199511093331901 · Cited by 666
Management of dyslipidemia in children and adolescents with diabetes
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.7.2194 · Cited by 438
Barrett-Connor, E., & Ferrara, A. (1998) · Diabetes Care · doi:10.2337/diacare.21.8.1236 · Cited by 369
Avignon, A., Radauceanu, A., & Monnier, L. (1997) · Diabetes Care · doi:10.2337/diacare.20.12.1822 · Cited by 363
Gastric emptying in diabetes: clinical significance and treatment
Horowitz, M., O’Donovan, D., Jones, K. L., Feinle, C., Rayner, C. K., & Samsom, M. (2002) · Diabetic Medicine · doi:10.1046/j.1464-5491.2002.00658.x · Cited by 308
Chase, H. P., Saib, S. Z., MacKenzie, T., Hansen, M. M., & Garg, S. K. (2002) · Diabetic Medicine · doi:10.1046/j.1464-5491.2002.00685.x · Cited by 116
Raskin, P., Holcombe, J. H., Tamborlane, W. V., Malone, J. I., Strowig, S., Ahern, J. A., & Lavent, F. (2001) · Journal of Diabetes and its Complications · doi:10.1016/s1056-8727(01)00168-4 · Cited by 71
Giacco, R., Brighenti, F., Parillo, M., Capuano, M., Ciardullo, A. V., Rivieccio, A., Rivellese, A. A., & Riccardi, G. (2001) · British Journal of Nutrition · doi:10.1079/bjn2000218 · Cited by 43
Cited by
Bell, K. J., Smart, C. E., Steil, G. M., Brand-Miller, J. C., King, B., & Wolpert, H. A. (2015) · Diabetes Care · doi:10.2337/dc15-0100 · Cited by 390
Insulin-pump therapy for type 1 diabetes mellitus
Pickup, J. C. (2012) · New England Journal of Medicine · doi:10.1056/nejmct1113948 · Cited by 270
Peters, A. L., Ahmann, A. J., Battelino, T., Evert, A., Hirsch, I. B., Murad, M. H., Winter, W. E., & Wolpert, H. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2534 · Cited by 250
Smart, C. E. M., Evans, M., O’Connell, S. M., McElduff, P., Lopez, P. E., Jones, T. W., Davis, E. A., & King, B. R. (2013) · Diabetes Care · doi:10.2337/dc13-1195 · Cited by 240
Annan, S. F., Higgins, L. A., Jelleryd, E., Hannon, T., Rose, S., Salis, S., Baptista, J., Chinchilla, P., & Marcovecchio, M. L. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13429 · Cited by 143
Metadata
- Authors
- Jones, S. M., Quarry, J. L., Caldwell-McMillan, M., Mauger, D. T., & Gabbay, R. A.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2005-04
- Volume
- 7
- Issue
- 2
- Pages
- 233-240
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2061220299
- Cited by
- 92
- References
- 10
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Insulin Pump Dosing and Postprandial Glycemia Following a Pizza Meal Using the Continuous Glucose Monitoring System. https://app.cochat.ai/papers/10.1089/dia.2005.7.233
- The paper
- Jones, S. M., Quarry, J. L., Caldwell-McMillan, M., Mauger, D. T., & Gabbay, R. A. (2005). Optimal Insulin Pump Dosing and Postprandial Glycemia Following a Pizza Meal Using the Continuous Glucose Monitoring System. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2005.7.233
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.