Evaluation of a New Blood Glucose Monitoring System with Auto-Calibration

Kilo, Charles, Pinson, Mary, Joynes, Judy Ostrom, Joseph, Hal, Monhaut, Nanette, Parkes, Joan Lee, Baum, John · 2005 · Diabetes Technology & Therapeutics
Cited by 15

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The Ascensia CONTOUR System (Bayer HealthCare LLC, Elkhart, IN) is a new blood glucose (BG) monitoring system (BGMS) that uses glucose dehydrogenase chemistry and that combines low sample volume, fast response time, an auto-control marking feature, and an auto-calibration function in a small package. METHODS: The system was evaluated at four diabetes clinics with ambulatory subjects who had diabetes. The BGMS was tested by both health care professionals (HCPs) and lay users. It was also evaluated at high altitude (10,200 feet) and, in conjunction with the Ascensia MICROLET VACULANCE (Bayer), for use with samples obtained from four alternative anatomical sites. RESULTS: When the system was used with blood from fingersticks, both lay users and HCPs obtained results that fulfilled the International Organization for Standardization (ISO) 15197:2003 accuracy criteria, which advocate that 95% of BG measurements should fall within +/-15 mg/dL (for BG concentrations <75 mg/dL) or +/-20% (for BG concentrations > or = 75 mg/dL) of the laboratory value. Lay users obtained 96.9% of glucose results, and HCPs obtained 96.4% of glucose results, within ISO accuracy criteria. People with diabetes who had no prior experience using the system also obtained acceptable results (97.0%), as did the HCP using fingerstick samples from subjects in the high altitude study (97.0%). Among the alternative anatomical sites tested, only the results from the palm met the ISO criteria (97.5%), although the results from all four sites (palm, thigh, abdomen, and forearm) were clinically acceptable when assessed using error grid analysis. Most subjects rated the BGMS as either excellent or very good in a questionnaire, and were able to use it properly without training. CONCLUSIONS: These findings indicate that the Ascensia CONTOUR System, which does not require calibration by the user, is a convenient and accurate instrument with useful features for people who routinely monitor BG.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2005.7.283

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Kilo, C., Pinson, M., Joynes, J. O., Joseph, H., Monhaut, N., Parkes, J. L., & Baum, J.
Venue
Diabetes Technology & Therapeutics
Published
2005-04
Volume
7
Issue
2
Pages
283-294
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W1976968063
Cited by
15
References
8
FWCI
0.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.