CoChat

Clinical Impact of Blood Glucose Monitoring Accuracy: An In-Silico Study

Open access
Campos-Náñez, Enrique, Fortwaengler, Kurt, Breton, Marc D. · 2017 · Journal of Diabetes Science and Technology

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Abstract

Background: Patients with diabetes rely on blood glucose (BG) monitoring devices to manage their condition. As some self-monitoring devices are becoming more and more accurate, it becomes critical to understand the relationship between system accuracy and clinical outcomes, and the potential benefits of analytical accuracy. Methods: We conducted a 30-day in-silico study in type 1 diabetes mellitus (T1DM) patients using continuous subcutaneous insulin infusion (CSII) therapy and a variety of BG meters, using the FDA-approved University of Virginia (UVA)/Padova Type 1 Simulator. We used simulated meter models derived from the published characteristics of 43 commercial meters. By controlling random events in each parallel run, we isolated the differences in clinical performance that are directly associated with the meter characteristics. Results: A meter’s systematic bias has a significant and inverse effect on HbA1c ( P < .01), while also affecting the number of severe hypoglycemia events. On the other hand, error, defined as the fraction of measurements beyond 5% of the true value, is a predictor of severe hypoglycemia events ( P < .01), but in the absence of bias has a nonsignificant effect on average glycemia (HbA1c). Both bias and error have significant effects on total daily insulin (TDI) and the number of necessary glucose measurements per day ( P < .01). Furthermore, these relationships can be accurately modeled using linear regression on meter bias and error. Conclusions: Two components of meter accuracy, bias and error, clearly affect clinical outcomes. While error has little effect on HbA1c, it tends to increase episodes of severe hypoglycemia. Meter bias has significant effects on all considered metrics: a positive systemic bias will reduce HbA1c, but increase the number of severe hypoglycemia attacks, TDI use, and number of fingersticks per day.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1932296817710474

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. Project approach to estimating clinical impacts of meter accuracy.
Figure 1. Project approach to estimating clinical impacts of meter accuracy.CC BY · PubMed Central
Figure 2. Example simulated glucose readings using our modeling approach.
Figure 2. Example simulated glucose readings using our modeling approach.CC BY · PubMed Central
Figure 3. Description of the elements of the basic behavioral model.
Figure 3. Description of the elements of the basic behavioral model.CC BY · PubMed Central
Figure 4. Relationship between consecutive meal times and sizes, using values of δt=15(min),andδa=20(g).
Figure 4. Relationship between consecutive meal times and sizes, using values of δt=15(min),andδa=20(g).CC BY · PubMed Central
Figure 5. Behavioral model of bolus and fingerstick behavior.
Figure 5. Behavioral model of bolus and fingerstick behavior.CC BY · PubMed Central
Figure 6. Relationship between error, bias, HbA1c, and severe hypoglycemia. Each meter is represented by a colored dot. The x-coordinate represents error, while the y-coordinate represents the resulting HbA1c. The size of the dot is proportional to the number of severe hypoglycemia events in 6 months, while the dot’s color shows the meter’s systematic bias.
Figure 6. Relationship between error, bias, HbA1c, and severe hypoglycemia. Each meter is represented by a colored dot. The x-coordinate represents error, while the y-coordinate represents the resulting HbA1c. The size of the dot is proportional to the number of severe hypoglycemia events in 6 months, while the dot’s color shows the meter’s systematic bias.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Research works printed but not linked: 1

  1. 10.1093/clinchem/47.2.209 · DOI · Paper page

Cited by

See all 22

Metadata

Authors
Campos-Náñez, E., Fortwaengler, K., & Breton, M. D.
Affiliations
  • University of Virginia (US)
  • Roche Diabetes Care GmbH (Germany) (DE)
Corresponding author
Breton, Marc D.
Venue
Journal of Diabetes Science and Technology
Published
2017-06-01
Volume
11
Issue
6
Pages
1187-1195
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2620577907
Cited by
22
References
36
Citations by year
2025: 1 · 2023: 2 · 2022: 3 · 2021: 1 · 2020: 5 · 2019: 4 · 2018: 4 · 2017: 2
FWCI
3.24
Type
journal article
Language
en
Open access
Licence
  • cc-by
  • journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Diabetes Science and Technology (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
Keywords
blood glucose meter accuracy, measurement error, type 1 diabetes, insulin pump therapy, HbA1c, severe hypoglycemia, computer simulation
MeSH terms
Blood Glucose, Computer Simulation, Diabetes Mellitus, Type 1, Equipment Design, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Models, Biological, Predictive Value of Tests, Signal Processing, Computer-Assisted, Transducers, Blood Glucose Self-Monitoring, Reproducibility of Results, Biomarkers, Linear Models, Treatment Outcome, Infusions, Subcutaneous

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical Impact of Blood Glucose Monitoring Accuracy: An In-Silico Study. https://app.cochat.ai/papers/10.1177/1932296817710474
The paper
Campos-Náñez, E., Fortwaengler, K., & Breton, M. D. (2017). Clinical Impact of Blood Glucose Monitoring Accuracy: An In-Silico Study. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296817710474

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.