Background: Clinical trials assessing the impact of errors in self-monitoring of blood glucose (SMBG) on the quality of glycemic control in diabetes are inherently difficult to execute. Consequently, the objectives of this study were to employ realistic computer simulation based on a validated model of the human metabolic system and to provide potentially valuable information about the relationships among SMBG errors, risk for hypoglycemia, glucose variability, and long-term glycemic control. Methods: Sixteen thousand computer simulation trials were conducted using 100 simulated adults with type 1 diabetes. Each simulated subject was used in four simulation experiments aiming to assess the impact of SMBG errors on detection of hypoglycemia (experiment 1), risk for hypoglycemia (experiment 2), glucose variability (experiment 3), and long-term average glucose control, i.e., estimated hemoglobin A1c (HbA1c)(experiment 4). Each experiment was repeated 10 times at each of four increasing levels of SMBG errors: 5, 10, 15, and 20% deviation from the true blood glucose value. Results: When the permitted SMBG error increased from 0 to 5–10% to 15–20%—the current level allowed by International Organization for Standardization 15197—(1) the probability for missing blood glucose readings of 60 mg/dl increased from 0 to 0–1% to 3.5–10%; (2) the incidence of hypoglycemia, defined as reference blood glucose ≤70 mg/dl, changed from 0 to 0–0% to 0.1–5.5%; (3) glucose variability increased as well, as indicated by control variability grid analysis; and (4) the incidence of hypoglycemia increased from 15.0 to 15.2–18.8% to 22–25.6%. When compensating for this increase, glycemic control deteriorated with HbA1c increasing gradually from 7.00 to 7.01–7.12% to 7.26–7.40%. Conclusions: A number of parameters of glycemic control deteriorated substantially with the increase of permitted SMBG errors, as revealed by a series of computer simulations (e.g., in silico) experiments. A threshold effect apparent between 10 and 15% permitted SMBG error for most parameters, except for HbA1c, which appeared to be increasing relatively linearly with increasing SMBG error above 10%.

Integrity signals

Registry

Crossref · 10.1177/193229681000400309

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The probability to measure blood glucose monitoring system results >70 mg/dL with a 'true' glucose concentration of 60 mg/dL increased 10-fold when the allowed range within which 95% of results were found is increased from ±7 mg/dL or ±10% to ±15 mg/dL or ±20%.

    “They found that the probability to measure BGMS results >70 mg/dL (3.88 mmol/L) with a “true” glucose concentration of 60 mg/dL (3.33 mmol/L) increased 10-fold when the allowed range within which 95% of results were found is increased from ±7 mg/dL (0.39 mmol/L) or ±10% (for glucose concentrations <75 mg/dL (4.16 mmol/L) or ≥75 mg/dL (4.16 mmol/L), respectively) to ±15 mg/dL (0.83 mmol/L) or ±20%.”
  • Increasingly inaccurate blood glucose monitoring system results lead to higher glycemic variability when pre-meal and insulin correction boluses were integrated in the model.

    “Furthermore, increasingly inaccurate BGMS results were found to lead to higher glycemic variability when pre-meal and insulin correction boluses were integrated in the model.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Breton, M. D., & Kovatchev, B. P.
Affiliations
University of Virginia (US)
Venue
Journal of Diabetes Science and Technology
Published
2010-05
Volume
4
Issue
3
Pages
562-570
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2124281539
Cited by
103
References
6
Citations by year
2026: 1 · 2025: 4 · 2024: 4 · 2022: 6 · 2021: 6 · 2020: 9 · 2019: 4 · 2018: 13 · 2017: 12 · 2016: 6 · 2015: 12 · 2014: 9 · 2013: 9 · 2012: 4
FWCI
4.12
Type
journal article
Language
en
Open access
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r01dk051562-23)
  • National Institute of Diabetes and Digestive and Kidney Diseases (R01DK 51562, R01-DK-051562)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Health Professions › Emergency Medical Services › Patient Safety and Medication Errors
Keywords
self-monitoring of blood glucose, type 1 diabetes, hypoglycemia risk, glycemic variability, glycemic control, HbA1c, computer simulation, hypoglycemia detection
MeSH terms
Blood Glucose, Computer Simulation, Diabetes Mellitus, Type 1, Humans, Hypoglycemia, Risk Factors, Self Administration, Blood Glucose Self-Monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review