Noninvasive Continuous Glucose Monitoring Using Photoacoustic Technology—Results from the First 62 Subjects
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Continuous glucose monitoring is a useful tool for the achievement of improved glucose control in patients with diabetes. We tested the ability of a novel noninvasive continuous glucose monitor to track glucose excursions. METHODS: The novel noninvasive Aprise sensor (Glucon Inc., Boulder, CO) utilizes the photoacoustic properties of the blood to infer the prevailing glucose levels. The performance of this sensor was tested in 62 subjects with diabetes who underwent an oral glucose tolerance, mixed meal, or glucose infusion test. RESULTS: The analysis included 979 pairs of reference values and sensor-derived glucose determinations. The mean of the relative absolute difference (RAD) of the sample was 19.9% with a median RAD of 13.2%. When results were plotted using the Clarke error grid, 66.5%, 28.1%, 1%, 4.4%, and 0% were within the A, B, C, D, and E ranges, respectively. The mean RAD for the oral glucose tolerance tests and meal tolerance tests was superior to the mean RAD of the glucose infusion studies (17% vs. 19% vs. 22%, respectively). CONCLUSIONS: Continuous noninvasive glucose monitoring using the Aprise sensor provides promising results. Such device may increase patient compliance and improve diabetes management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
(2000) · New England Journal of Medicine · doi:10.1056/nejm200002103420603 · Cited by 1,534
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Cited by
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Niu, X., Lan, M., Zhao, H., & Chen, C. (2013) · Analytical Chemistry · doi:10.1021/ac3030976 · Cited by 412
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Metadata
- Authors
- Weiss, R., Yegorchikov, Y., Shusterman, A., & Raz, I.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2007-02
- Volume
- 9
- Issue
- 1
- Pages
- 68-74
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1993964679
- Cited by
- 86
- References
- 3
- FWCI
- 2.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.