Development of a Real-Time Corneal Birefringence Compensated Glucose Sensing Polarimeter
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: As is well known, in order to optimally manage diabetes mellitus, monitoring blood glucose levels several times daily is recommended so appropriate actions can be taken to maintain these levels within a near-normal physiologic range. One technique that shows promise is the use of optical polarimetry. This technique has the potential to noninvasively measure physiological glucose levels in the eye that are correlated to blood glucose concentrations. To date, the main factor limiting in vivo polarimetric glucose measurements is corneal birefringence, which tends to mask the glucose signature. In this investigation, a method to compensate for the effects of corneal birefringence is demonstrated, thus allowing for polarimetric glucose measurements in samples with time-varying birefringence contributions. METHODS: In this paper, using a custom-designed laser-based optical polarimetry system with an integrated birefringence compensator, noninvasive glucose measurements in the physiological range are accurately measured within various birefringent samples similar in structure to the eye. RESULTS: Using the laser-based polarimetric approach, it is shown that glucose levels within the physiological range in the presence of significant varying birefringence can be accurately predicted with as low as 13.84 mg/dL error. CONCLUSIONS: The ability to compensate for corneal birefringence effects provides promise for the eventual development of a commercial home-based noninvasive polarimetric glucose monitor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spatial mapping of polarized light transmission in the central rabbit cornea
CHRISTENS-BARRY, W. A., GREEN, W. J., CONNOLLY, P. J., FARRELL, R. A., & MCCALLY, R. L. (1996) · Experimental Eye Research · doi:10.1006/exer.1996.0076 · Cited by 18
Cited by
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Ex-vivo characterization of human colon cancer by Mueller polarimetric imaging
Pierangelo, A., Benali, A., Antonelli, M.-R., Novikova, T., Validire, P., Gayet, B., & De Martino, A. (2011) · Optics Express · doi:10.1364/oe.19.001582 · Cited by 294
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Advances in Biosensors for Continuous Glucose Monitoring Towards Wearables
Johnston, L., Wang, G., Hu, K., Qian, C., & Liu, G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.733810 · Cited by 180
Metadata
- Authors
- Cameron, B. D., & Anumula, H.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2006-04
- Volume
- 8
- Issue
- 2
- Pages
- 156-164
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1985323714
- Cited by
- 42
- References
- 1
- FWCI
- 1.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a Real-Time Corneal Birefringence Compensated Glucose Sensing Polarimeter. https://app.cochat.ai/papers/10.1089/dia.2006.8.156
- The paper
- Cameron, B. D., & Anumula, H. (2006). Development of a Real-Time Corneal Birefringence Compensated Glucose Sensing Polarimeter. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2006.8.156
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.