CoChat

In Vitro Stability of Insulin Lispro in Continuous Subcutaneous Insulin Infusion

DeFelippis, Michael R., Bell, Maureen A., Heyob, Jennifer A., Storms, Sacha M. · 2006 · Diabetes Technology & Therapeutics
Cited by 41

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The stability of insulin lispro for use in continuous subcutaneous insulin infusion (CSII) therapy was evaluated using a stress test incorporating high temperature and mechanical agitation combined with simulated basal/bolus administration. METHODS: Insulin lispro formulation contained in MiniMed 507c (Medtronic MiniMed, Sylmar, CA), H-TRONplus (Disetronic Medical Systems, St. Paul, MN), and D-TRON CSII (Disetronic Medtronic Systems) devices was subjected to a stress test involving exposure to elevated temperature (37 degrees C) and mechanical agitation (shaking at 100 strokes/min) for 7 days. CSII devices were programmed for continuous infusion at 0.8 U/h (19.2 U/day), and three 6-U bolus doses were also manually delivered each day (18 U/day). Formulation infused from the devices was collected every 24 h over the 7-day study. The material obtained from each 24-h period was analyzed to assess the physicochemical properties of insulin lispro and the overall formulation. Insulin lispro potency, purity, high-molecular-weight protein (HMWP), and m-cresol content were determined using high-performance liquid chromatographic methods. Solution pH, delivered volume, and formulation physical appearance were also evaluated. RESULTS: The pH of the infused formulation remained unchanged throughout the entire study. Insulin lispro potency for each device remained within 95-105% of label claim each day of the stress test, indicating that adsorption or surface-induced denaturation of insulin lispro did not occur. Levels of insulin lispro deamidated at position 21 in the A-chain were essentially constant during the 7-day stress test. A time-dependent increase in HMWP and other insulin lispro chemical transformation products was observed over the testing period for each device. However, the levels of these known degradation products remained well below published specifications for these analytical properties. The concentration of the antimicrobial agent, m-cresol, was decreased because of absorption, but the levels remained sufficient to provide protection against microbial contamination. Total delivered volume results were in good agreement with expected values and confirmed that formulation viscosity remained unchanged. Samples collected from the infusion sets were clear and free of precipitates. Occlusion alarms did not occur, and no other electronic or mechanical malfunctions of the CSII devices were encountered. CONCLUSIONS: Insulin lispro demonstrates appropriate physicochemical stability for use in MiniMed 507c, H-TRONplus, and D-TRON CSII devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2006.8.358

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
DeFelippis, M. R., Bell, M. A., Heyob, J. A., & Storms, S. M.
Venue
Diabetes Technology & Therapeutics
Published
2006-06
Volume
8
Issue
3
Pages
358-368
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2074628239
Cited by
41
References
2
FWCI
2.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.