Estimation of Future Glucose Concentrations with Subject-Specific Recursive Linear Models
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Estimation of future glucose concentrations is a crucial task for diabetes management. Predicted glucose values can be used for early hypoglycemic/hyperglycemic alarms or for adjustment of insulin injections or insulin infusion rates of manual or automated pumps. Continuous glucose monitoring (CGM) technologies provide glucose readings at a high frequency and consequently detailed insight into the subject's glucose variations. The objective of this research is to develop reliable subject-specific glucose prediction models using CGM data. METHODS: Two separate patient databases collected under hospitalized (disturbance-free) and normal daily life conditions are used for validation of the proposed glucose prediction algorithm. Both databases consist of glucose concentration data collected at 5-min intervals using a CGM device. Using time-series analysis, low-order linear models are developed from patients' own CGM data. The time-series models are integrated with recursive identification and change detection methods, which enables dynamic adaptation of the model to inter-/intra-subject variability and glycemic disturbances. Prediction performance is evaluated in terms of glucose prediction error and Clarke Error Grid analysis (CG-EGA). RESULTS: Prediction errors are significantly reduced with recursive identification of the models, and predictions are further improved with inclusion of a parameter change detection method. CG-EGA analysis results in accurate readings of 90% or more. CONCLUSIONS: Subject-specific glucose prediction strategy has been developed. Including a change detection method to the recursive algorithm improves the prediction accuracy. The proposed modeling algorithm with small number of parameters is a good candidate for installation in portable devices for early hypoglycemic/hyperglycemic alarms and for closing the glucose regulation loop with an insulin pump.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274 · cited 5×
“Reducing the moving average part (q), ARMA(2,0) or AR(2), leads to consistent overshoot and higher SSGPE and RAD values (3.”
InfluentialPartitioning glucose distribution/transport, disposal, and endogenous production during IVGTT
Hovorka, R., Shojaee-Moradie, F., Carroll, P. V., Chassin, L. J., Gowrie, I. J., Jackson, N. C., Tudor, R. S., Umpleby, A. M., & Jones, R. H. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00304.2001 · Cited by 393
Evaluating the Accuracy of Continuous Glucose-Monitoring Sensors
Kovatchev, B. P., Gonder-Frederick, L. A., Cox, D. J., & Clarke, W. L. (2004) · Diabetes Care · doi:10.2337/diacare.27.8.1922 · Cited by 312 · cited 1×
“26,27 CG-EGA creates three error grid zones (clinically accurate, benign errors, and erroneous readings) for analyzing the prediction accuracy and provides separate”
Cited by
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“eling techniques [227]–[233], but neural networks [234], [235] and other physiological structural models [236] have been used”
Xie, J., & Wang, Q. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2975959 · Cited by 158
Cichosz, S. L., Frystyk, J., Hejlesen, O. K., Tarnow, L., & Fleischer, J. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814528838 · Cited by 88
An Integrated Multivariable Artificial Pancreas Control System
Turksoy, K., Quinn, L. T., Littlejohn, E., & Cinar, A. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814524862 · Cited by 77
Self-citationZecchin, C., Facchinetti, A., Sparacino, G., & Cobelli, C. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816654161 · Cited by 64
“ (8) TG is an easy to compute index.”
Metadata
- Authors
- Eren-Oruklu, M., Cinar, A., Quinn, L., & Smith, D.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2009-04
- Volume
- 11
- Issue
- 4
- Pages
- 243-253
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2094743912
- Cited by
- 149
- References
- 4
- FWCI
- 8.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.