Can We Really Close the Loop and How Soon? Accelerating the Availability of an Artificial Pancreas: A Roadmap to Better Diabetes Outcomes
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Development of a closed-loop artificial pancreas has been a long-time goal that could transform diabetes management. The primary limitation until recent years was the lack of a robust and portable continuous glucose sensor. There has been significant progress over the past 5 years in the development and commercialization of continuous glucose monitoring (CGM) devices. Used adjunctively, CGM has been demonstrated to add significant value in improving diabetes management by increasing time spent in glycemic targets and improving overall glycemic control. However, these benefits are limited by the human user's finite capacity to respond to the data provided by the device. By automating even a portion of the insulin delivery functionality of combined sensor/pump systems via computer algorithm, impending excursions could be handled more quickly and effectively. This review will describe very promising preliminary closed-loop studies, describe a potential roadmap to an artificial pancreas that will be safe and effective, and propose a solution-a hypo- and hyperglycemia minimizing control-to-range approach-that may allow for near-term delivery of a semiautomated system to people with diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Translating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Assessing Psychosocial Distress in Diabetes
Polonsky, W. H., Fisher, L., Earles, J., Dudl, R. J., Lees, J., Mullan, J., & Jackson, R. A. (2005) · Diabetes Care · doi:10.2337/diacare.28.3.626 · Cited by 1,575
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Assessment of Diabetes-Related Distress
Polonsky, W. H., Anderson, B. J., Lohrer, P. A., Welch, G., Jacobson, A. M., Aponte, J. E., & Schwartz, C. E. (1995) · Diabetes Care · doi:10.2337/diacare.18.6.754 · Cited by 1,497
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Development of a brief diabetes distress screening instrument
Fisher, L., Glasgow, R. E., Mullan, J. T., Skaff, M. M., & Polonsky, W. H. (2008) · The Annals of Family Medicine · doi:10.1370/afm.842 · Cited by 474
Clinical Depression Versus Distress Among Patients With Type 2 Diabetes
Fisher, L., Skaff, M. M., Mullan, J. T., Arean, P., Mohr, D., Masharani, U., Glasgow, R., & Laurencin, G. (2007) · Diabetes Care · doi:10.2337/dc06-1614 · Cited by 465
Snoek, F. J., Pouwer, F., Welch, G. W., & Polonsky, W. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.9.1305 · Cited by 444
Hollander, P. A., Levy, P., Fineman, M. S., Maggs, D. G., Shen, L. Z., Strobel, S. A., Weyer, C., & Kolterman, O. G. (2003) · Diabetes Care · doi:10.2337/diacare.26.3.784 · Cited by 307
Ratner, R. E., Dickey, R., Fineman, M., Maggs, D. G., Shen, L., Strobel, S. A., Weyer, C., & Kolterman, O. G. (2004) · Diabetic Medicine · doi:10.1111/j.1464-5491.2004.01319.x · Cited by 307
Cited by
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“Recently, it has been proposed that implementation of “semi closed-loop” glucose control, only using the safety module, without the real-time control, could offer a first step towards full-closed loop control [253].”
Continuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes
Rodbard, D. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0035 · Cited by 458
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Bergenstal, R. M., Ahmann, A. J., Bailey, T., Beck, R. W., Bissen, J., Buckingham, B., Deeb, L., Dolin, R. H., Garg, S. K., Goland, R., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0051 · Cited by 307
Electrochemical Glucose Sensing: Is There Still Room for Improvement?
Witkowska Nery, E., Kundys, M., Jeleń, P. S., & Jönsson-Niedziółka, M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03151 · Cited by 292
Metadata
- Authors
- Kowalski, A. J.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2009-06-02
- Volume
- 11
- Issue
- S1
- Pages
- S-113-S-119
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2080500932
- Cited by
- 127
- References
- 18
- FWCI
- 8.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Can We Really Close the Loop and How Soon? Accelerating the Availability of an Artificial Pancreas: A Roadmap to Better Diabetes Outcomes. https://app.cochat.ai/papers/10.1089/dia.2009.0031
- The paper
- Kowalski, A. J. (2009). Can We Really Close the Loop and How Soon? Accelerating the Availability of an Artificial Pancreas: A Roadmap to Better Diabetes Outcomes. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2009.0031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.