Prevention of Hypoglycemia by Using Low Glucose Suspend Function in Sensor-Augmented Pump Therapy
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Severe hypoglycemic episodes are a barrier for achieving optimal glycemic control. Sensor-augmented pump (SAP) therapy with insulin in combination with a novel mechanism of automatic insulin shutoff (low glucose suspend [LGS]) can be used to prevent and reduce hypoglycemia. In a prospective study, we investigated the effect of the LGS algorithm on the frequency of hypoglycemia in children and adolescents with type 1 diabetes under real-life conditions. METHODS: Twenty-one patients with type 1 diabetes (10.8±3.8 years old, duration of diabetes 5.9±3.0 years, pump therapy for 3.7±1.7 years, glycated hemoglobin level 7.8±1.1%) from three pediatric centers used the Paradigm(®) Veo(™) system (Medtronic Minimed, Northridge, CA) during two subseqent time periods: SAP without LGS for 2 weeks and then SAP with LGS enabled for 6 weeks. The primary objective was to assess the frequency of hypoglycemic episodes when using the LGS feature with an insulin delivery shutoff of a maximum of 2 h at a sensor glucose level below 70 mg/dL (3.9 mmol/L). RESULTS: In total, 1,298 LGS alerts occurred (853 shorter than 5 min). Forty-two percent of LGS activations (>5 min) lasted less than 30 min, whereas 24% had a duration of 2 h. The number of hypoglycemic excursions (average/day) was reduced during SAP+LGS (<70 mg/L, 1.27±0.75 vs. 0.95±0.49, P=0.010; ≤40 mg/dL, 0.28±0.18 vs. 0.13±0.14, P=0.005) as was the time spent in hypoglycemia (average minutes/day, 101±68 vs. 58±33, P=0.002) without significant difference in the mean glucose level (145±23 vs. 148±19 mg/dL). No episodes of severe hyperglycemia or diabetic ketoacidosis were observed following LGS activation. CONCLUSIONS: The present investigation provides evidence that SAP with LGS reduces the frequency of hypoglycemia without compromising safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cryer, P. E., Davis, S. N., & Shamoon, H. (2003) · Diabetes Care · doi:10.2337/diacare.26.6.1902 · Cited by 1,160 · cited 1×
“18 Children with type 1 diabetes are particularly prone to hypoglycemia, 19 which leads to significant parental anxiety adding complexity to this issue.”
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Danne, T., Mortensen, H. B., Hougaard, P., Lynggaard, H., Aanstoot, H.-J., Chiarelli, F., Daneman, D., Dorchy, H., Garandeau, P., Greene, S. A., et al. (2001) · Diabetes Care · doi:10.2337/diacare.24.8.1342 · Cited by 299
Self-citationOptimal sampling intervals to assess long-term glycemic control using continuous glucose monitoring
Xing, D., Kollman, C., Beck, R. W., Tamborlane, W. V., Laffel, L., Buckingham, B. A., Wilson, D. M., Weinzimer, S., Fiallo-Scharer, R., & Ruedy for the Juvenile Diabetes Research Foundation Continuo, K. J. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0156 · Cited by 131
Amin, R., Ross, K., Acerini, C. L., Edge, J. A., Warner, J., & Dunger, D. B. (2003) · Diabetes Care · doi:10.2337/diacare.26.3.662 · Cited by 106
Cited by
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Ly, T. T., Nicholas, J. A., Retterath, A., Lim, E. M., Davis, E. A., & Jones, T. W. (2013) · JAMA · doi:10.1001/jama.2013.277818 · Cited by 411
Insulin delivery methods: Past, present and future
Shah, R., Shah, V., Patel, M., & Maahs, D. (2016) · International Journal of Pharmaceutical Investigation · doi:10.4103/2230-973x.176456 · Cited by 287
Assessing Sensor Accuracy for Non-Adjunct Use of Continuous Glucose Monitoring
Kovatchev, B. P., Patek, S. D., Ortiz, E. A., & Breton, M. D. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0272 · Cited by 234
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Metadata
- Authors
- Danne, T., Kordonouri, O., Holder, M., Haberland, H., Golembowski, S., Remus, K., Bläsig, S., Wadien, T., Zierow, S., Hartmann, R., & Thomas, A.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2011-11
- Volume
- 13
- Issue
- 11
- Pages
- 1129-1134
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1977806121
- Cited by
- 151
- References
- 6
- FWCI
- 18.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.