Use of Microneedle Array Devices for Continuous Glucose Monitoring: A Review
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Microneedle array devices provide the opportunity to overcome the barrier characteristics of the outermost skin layer, the stratum corneum. This novel technology can be used as a therapeutic tool for transdermal drug delivery, including insulin, or as a diagnostic tool providing access to dermal biofluids, with subsequent analysis of its contents. Over the last decade, the use of microneedle array technology has been the focus of extensive research in the field of transdermal drug delivery. More recently, the diagnostic applications of microneedle technology have been developed. This review summarizes the existing evidence for the use of microneedle array technology as biosensors for continuous monitoring of the glucose content of interstitial fluid, focusing also on mechanics of insertion, microchannel characteristics, and safety profile.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584 · cited 1×
“12 Comparison of glucose levels in dermal ISF and finger capillary blood showed high correlation with estimated lag time between 0 and 45 min.”
Self-citationPickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Assessing Glycemia in Diabetes Using Self-monitoring Blood Glucose and Hemoglobin A 1c
Saudek, C. D., Derr, R. L., & Kalyani, R. R. (2006) · JAMA · doi:10.1001/jama.295.14.1688 · Cited by 373
Ehrhardt, N. M., Chellappa, M., Walker, M. S., Fonda, S. J., & Vigersky, R. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500320 · Cited by 199
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Han, D., Morde, R. S., Mariani, S., La Mattina, A. A., Vignali, E., Yang, C., Barillaro, G., & Lee, H. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909197 · Cited by 360
Recent advances in cortisol sensing technologies for point-of-care application
Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.060 · Cited by 316
“Micromachined microneedles for transdermal application are another option to harvest ISF (El-Laboudi et al., 2013; Prausnitz, 2004).”
BackgroundLab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310
Electrochemical Glucose Sensing: Is There Still Room for Improvement?
Witkowska Nery, E., Kundys, M., Jeleń, P. S., & Jönsson-Niedziółka, M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03151 · Cited by 292
Continuous minimally-invasive alcohol monitoring using microneedle sensor arrays
Mohan, A. M. V., Windmiller, J. R., Mishra, R. K., & Wang, J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.016 · Cited by 274
Microneedle-based biosensor for minimally-invasive lactate detection
Bollella, P., Sharma, S., Cass, A. E. G., & Antiochia, R. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.010 · Cited by 267
Self-citationMicroneedles for drug delivery: trends and progress
Cheung, K., & Das, D. B. (2016) · Drug Delivery · doi:10.3109/10717544.2014.986309 · Cited by 244
“…the delivery and monitoring of various drugs such as glucose control for diabetics (Ito et al., 2006; Nordquist et al., 2007; Ainslie & Desai, 2008; El-Laboudi et al., 2013; Taylor & Sahota, 2013; Ita, 2014), Alzheimer’s disease (Wei-Ze et al., 2010), anticancer (Fang et al., 2008) and other…”
BackgroundGowers, S. A. N., Freeman, D. M. E., Rawson, T. M., Rogers, M. L., Wilson, R. C., Holmes, A. H., Cass, A. E., & O’Hare, D. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00288 · Cited by 159
Self-citation
Metadata
- Authors
- El-Laboudi, A., Oliver, N. S., Cass, A., & Johnston, D.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2013-01
- Volume
- 15
- Issue
- 1
- Pages
- 101-115
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1985134199
- Cited by
- 131
- References
- 6
- FWCI
- 4.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.