Nocturnal Continuous Glucose Monitoring: Accuracy and Reliability of Hypoglycemia Detection in Patients with Type 1 Diabetes at High Risk of Severe Hypoglycemia
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe hypoglycemia. PATIENTS AND METHODS: Seventy-two type 1 diabetes patients with recurrent severe hypoglycemia (two or more events within the last year) participated for 4 nights in blinded CGM recordings (Guardian(®) REAL-Time CGMS and Sof-Sensor(®); Medtronic MiniMed, Northridge, CA). Blood was drawn hourly from 23:00 to 07:00 h for plasma glucose (PG) measurements (gold standard). RESULTS: Valid data were obtained in 217 nights. The sensitivity of CGM was 65% (95% confidence interval, 53-77%) below 4 mmol/L, 40% (24-56%) below 3 mmol/L, and 17% (0-47%) below 2.2 mmol/L. PG and CGM readings correlated in the total measurement range (Spearman's ρ=0.82; P<0.001). In the normo- and hyperglycemic ranges CGM underestimated PG by 1.1 mmol/L (0.9-1.2 mmol/L) (P<0.001); in contrast, in the hypoglycemic range (PG<4 mmol/L) CGM overestimated PG levels by 1.0 mmol/L (P<0.001). The mean absolute relative differences in the hypo- (≤3.9 mmol/L), normo- (4-9.9 mmol/L), and hyperglycemic (≥10 mmol/L) ranges were 45% (37-53%), 23% (22-25%), and 20% (19-21%), respectively. Continuous glucose error grid analysis indicated a clinical accuracy of 56%, 99%, and 93% in the hypo-, normo-, and hyperglycemic ranges, respectively. CONCLUSIONS: The accuracy in the hypoglycemic range of nocturnal CGM data using Sof-Sensor is suboptimal in type 1 diabetes patients at high risk of severe hypoglycemia. To ensure clinical useful sensitivity in detection of nocturnal hypoglycemic episodes, an alarm threshold should not be lower than 4 mmol/L.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Risk of hypoglycaemia in types 1 and 2 diabetes: Effects of treatment modalities and their duration
UK Hypoglycaemia Study Group (2007) · Diabetologia · doi:10.1007/s00125-007-0599-y · Cited by 825
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Evaluating the Accuracy of Continuous Glucose-Monitoring Sensors
Kovatchev, B. P., Gonder-Frederick, L. A., Cox, D. J., & Clarke, W. L. (2004) · Diabetes Care · doi:10.2337/diacare.27.8.1922 · Cited by 312 · cited 1×
“11,12 ).”
Recall of severe hypoglycaemia and self‐estimated state of awareness in type 1 diabetes
Pedersen‐Bjergaard, U., Pramming, S., & Thorsteinsson, B. (2003) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.377 · Cited by 240
Self-citationUNRECOGNISED NOCTURNAL HYPOGLYCÆMIA IN INSULIN-TREATED DIABETICS
Gale, E. A. M., & Tattersall, R. B. (1979) · The Lancet · doi:10.1016/s0140-6736(79)92950-7 · Cited by 176
Cited by
Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm
Bailey, T. S., Chang, A., & Christiansen, M. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814559746 · Cited by 168
Cichosz, S. L., Johansen, M. D., & Hejlesen, O. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815611680 · Cited by 101
“It is known that CGM has a physiological lag time and, moreover, less precision in the lower glucose concentration range.(107-109) Knowing the underlying blood glucose level is therefore necessary.”
BackgroundFreckmann, G., Eichenlaub, M., Waldenmaier, D., Pleus, S., Wehrstedt, S., Haug, C., Witthauer, L., Jendle, J., Hinzmann, R., Thomas, A., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231190941 · Cited by 86
Henriksen, M. M., Andersen, H. U., Thorsteinsson, B., & Pedersen-Bjergaard, U. (2018) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2018-00142 · Cited by 57
Self-citationTschöpe, D., Bramlage, P., Schneider, S., & Gitt, A. K. (2016) · Diabetes and Vascular Disease Research · doi:10.1177/1479164115610470 · Cited by 12
Metadata
- Authors
- Bay, C., Kristensen, P. L., Pedersen-Bjergaard, U., Tarnow, L., & Thorsteinsson, B.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2013-05
- Volume
- 15
- Issue
- 5
- Pages
- 371-377
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2063298884
- Cited by
- 51
- References
- 5
- FWCI
- 5.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.