Electrochemiluminescence Assays for Insulin and Glutamic Acid Decarboxylase Autoantibodies Improve Prediction of Type 1 Diabetes Risk
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
We recently developed new electrochemiluminescence (ECL) insulin autoantibody (IAA) and glutamic acid decarboxylase 65 autoantibody (GADA) assays that discriminate high-affinity, high-risk diabetes-specific autoantibodies from low-affinity, low-risk islet autoantibodies (iAbs) detected by radioassay (RAD). Here, we report a further validation of the ECL-IAA and -GADA assays in 3,484 TrialNet study participants. The ECL assay and RAD were congruent in those with prediabetes and in subjects with multiple autoantibodies, but only 24% (P<0.0001) of single RAD-IAA-positive and 46% (P<0.0001) of single RAD-GADA-positive were confirmed by the ECL-IAA and -GADA assays, respectively. During a follow-up (mean, 2.4 years), 51% of RAD-IAA-positive and 63% of RAD-GADA-positive subjects not confirmed by ECL became iAb negative, compared with only 17% of RAD-IAA-positive (P<0.0001) and 15% of RAD-GADA-positive (P<0.0001) subjects confirmed by ECL assays. Among subjects with multiple iAbs, diabetes-free survival was significantly shorter if IAA or GADA was positive by ECL and negative by RAD than if IAA or GADA was negative by ECL and positive by RAD (P<0.019 and P<0.0001, respectively). Both positive and negative predictive values in terms of progression to type 1 diabetes mellitus were superior for ECL-IAA and ECL-GADA, compared with RADs. The prevalence of the high-risk human leukocyte antigen-DR3/4, DQB1*0302 genotype was significantly higher in subjects with RAD-IAA or RAD-GADA confirmed by ECL. In conclusion, both ECL-IAA and -GADA are more disease-specific and better able to predict the risk of progression to type 1 diabetes mellitus than the current standard RADs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seroconversion to multiple islet autoantibodies and risk of progression to diabetes in children
Ziegler, A. G., Rewers, M., Simell, O., Simell, T., Lempainen, J., Steck, A., Winkler, C., Ilonen, J., Veijola, R., Knip, M., et al. (2013) · JAMA · doi:10.1001/jama.2013.6285 · Cited by 1,312
Self-citationOrban, T., Sosenko, J. M., Cuthbertson, D., Krischer, J. P., Skyler, J. S., Jackson, R., Yu, L., Palmer, J. P., Schatz, D., Eisenbarth, G., et al. (2009) · Diabetes Care · doi:10.2337/dc09-0934 · Cited by 260 · cited 1×
“Accordingly, previous studies showed that T1DM risk increases with greater number of iAbs even among subjects with multiple iAbs.(6,14) The higher risk of T1DM with increasing number of iAbs may also reflect faster progression to T1D or that subjects with more iAbs are closer to clinical T1DM.”
Self-citationSteck, A. K., Johnson, K., Barriga, K. J., Miao, D., Yu, L., Hutton, J. C., Eisenbarth, G. S., & Rewers, M. J. (2011) · Diabetes Care · doi:10.2337/dc10-2088 · Cited by 195
Self-citationYu, L., Boulware, D. C., Beam, C. A., Hutton, J. C., Wenzlau, J. M., Greenbaum, C. J., Bingley, P. J., Krischer, J. P., Sosenko, J. M., Skyler, J. S., et al. (2012) · Diabetes Care · doi:10.2337/dc11-2081 · Cited by 104
Self-citationSiljander, H., Härkönen, T., Hermann, R., Simell, S., Hekkala, A., Salonsaari, R., Simell, T., Simell, O., Ilonen, J., Veijola, R., et al. (2009) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.998 · Cited by 30 · cited 1×
“This is consistent with previous reports from other laboratories 2–5 that both IAA and GADA in children who remained single autoantibody positive or became iAb negative had a significantly lower affinity than IAA and GADA in multiple It is well known that people with multiple iAbs are at high risk of…”
Cited by
Insel, R. A., Dunne, J. L., Atkinson, M. A., Chiang, J. L., Dabelea, D., Gottlieb, P. A., Greenbaum, C. J., Herold, K. C., Krischer, J. P., Lernmark, Å., et al. (2015) · Diabetes Care · doi:10.2337/dc15-1419 · Cited by 1,216
Self-citationLampasona, V., Pittman, D. L., Williams, A. J., Achenbach, P., Schlosser, M., Akolkar, B., Winter, W. E., Laboratories, P., Watson, K., Weets, I., et al. (2019) · Clinical Chemistry · doi:10.1373/clinchem.2019.304196 · Cited by 103
Self-citationPugliese, A., Boulware, D., Yu, L., Babu, S., Steck, A. K., Becker, D., Rodriguez, H., DiMeglio, L., Evans-Molina, C., Harrison, L. C., et al. (2016) · Diabetes · doi:10.2337/db15-1105 · Cited by 68
Self-citationPast, present and future of latent autoimmune diabetes in adults
Liu, B., Xiang, Y., Liu, Z., & Zhou, Z. (2020) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.3205 · Cited by 50
Zhu, Y., Qian, L., Liu, Q., Zou, J., Zhou, Y., Yang, T., Huang, G., Zhou, Z., & Liu, Y. (2020) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2019.0007 · Cited by 26
“Electrochemiluminescence (ECL) assay, an emerging method for islet autoantibody detection, can discriminate high-affinity, high-risk diabetes-specific antibodies from low-affinity, low-risk islet autoantibodies, and therefore be used to identify the initiation of islet autoimmunity at an earlier stage [11,12].”
MethodResultInfluential
Metadata
- Authors
- Miao, D., Steck, A. K., Zhang, L., Guyer, K. M., Jiang, L., Armstrong, T., Muller, S. M., Krischer, J., Rewers, M., Yu, L., & the Type 1 Diabetes TrialNet Study Group
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2015-02
- Volume
- 17
- Issue
- 2
- Pages
- 119-127
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1420585492
- Cited by
- 64
- References
- 5
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemiluminescence Assays for Insulin and Glutamic Acid Decarboxylase Autoantibodies Improve Prediction of Type 1 Diabetes Risk. https://app.cochat.ai/papers/10.1089/dia.2014.0186
- The paper
- Miao, D., Steck, A. K., Zhang, L., Guyer, K. M., Jiang, L., Armstrong, T., Muller, S. M., Krischer, J., Rewers, M., Yu, L., & the Type 1 Diabetes TrialNet Study Group. (2015). Electrochemiluminescence Assays for Insulin and Glutamic Acid Decarboxylase Autoantibodies Improve Prediction of Type 1 Diabetes Risk. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2014.0186
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.