CoChat

Cost-Effectiveness of Sensor-Augmented Pump Therapy with Low Glucose Suspend Versus Standard Insulin Pump Therapy in Two Different Patient Populations with Type 1 Diabetes in France

Roze, Stéphane, Smith-Palmer, Jayne, Valentine, William, Payet, Vincent, de Portu, Simona, Papo, Natalie, Cucherat, Michel, Hanaire, Helene · 2016 · Diabetes Technology & Therapeutics
Cited by 37

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Sensor-augmented pump therapy (SAP) provides a useful adjunct relative to continuous subcutaneous insulin infusion (CSII) alone. It can provide early warning of the onset of hyperglycemia and hypoglycemia and has the functionality to suspend insulin delivery if sensor glucose levels fall below a predefined threshold. The aim was to assess the cost-effectiveness of SAP with low glucose suspend (LGS) versus CSII alone in type 1 diabetes. MATERIALS AND METHODS: Cost-effectiveness analysis was performed using the CORE Diabetes Model, using published clinical input data. The analysis was performed in two cohorts: one with uncontrolled glycated hemoglobin at baseline and one at elevated risk for hypoglycemic events. The analysis was conducted from a healthcare payer perspective over a lifetime time horizon; future costs and clinical outcomes were discounted at 4% per annum. RESULTS: In patients with uncontrolled glycated hemoglobin at baseline, SAP + LGS resulted in improved discounted quality-adjusted life expectancy (QALE) versus CSII (10.55 quality-adjusted life-years [QALYs] vs. 9.36 QALYs) but higher mean lifetime direct costs (€84,972 vs. €49,171) resulting in an incremental cost-effectiveness ratio (ICER) of €30,163 per QALY gained. In patients at elevated risk for hypoglycemia, the ICER was €22,005 per QALY gained for SAP + LGS versus CSII as lifetime costs were higher (€88,680 vs. €57,097), but QALE was also higher (18.46 QALYs vs. 18.30 QALYs). CONCLUSIONS: In France, projected improvements in outcomes with SAP + LGS versus CSII translated into an ICER generally considered as good value for money, particularly in patients who experience frequent and/or problematic hypoglycemic events.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2015.0224

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 37

Metadata

Authors
Roze, S., Smith-Palmer, J., Valentine, W., Payet, V., de Portu, S., Papo, N., Cucherat, M., & Hanaire, H.
Venue
Diabetes Technology & Therapeutics
Published
2016-02
Volume
18
Issue
2
Pages
75-84
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2190078402
Cited by
37
References
10
FWCI
4.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.