Comparison of Two Continuous Glucose Monitoring Systems, Dexcom G4 Platinum and Medtronic Paradigm Veo Enlite System, at Rest and During Exercise

Taleb, Nadine, Emami, Ali, Suppere, Corinne, Messier, Virginie, Legault, Laurent, Chiasson, Jean-Louis, Rabasa-Lhoret, Rémi, Haidar, Ahmad · 2016 · Diabetes Technology & Therapeutics
Cited by 62

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Despite technological advances, the accuracy of continuous glucose monitoring (CGM) systems may not always be satisfactory with rapidly changing glucose levels, as is notable during exercise. We compare the performance of two current and widely used CGM systems, Dexcom G4 Platinum (Dexcom) and Medtronic Paradigm Veo Enlite system (Enlite), during both rest and exercise in adults with type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: Paired sensor and plasma glucose (PG) values (total of 431 data pairs for Dexcom and 425 for Enlite) were collected from 17 adults (37.3 ± 13.6 years) with T1D. To evaluate and compare the accuracy of sensor readings, criteria involving sensor bias (sensor minus PG levels), absolute relative difference (ARD), and percentage of readings meeting International Organization for Standardization (ISO) criteria were considered. RESULTS: Both Dexcom and Enlite performed equally well during the rest period, with respective mean/median biases of -0.12/-0.02 mmol/L versus -0.18/-0.40 (P = 0.78, P = 0.66) mmol/L and ARDs of 13.77/13.34% versus 12.38/11.95% (P = 0.53, P = 0.70). During exercise, sensor bias means/medians were -0.40/-0.21 mmol versus -0.26/-0.24 mmol/L (P = 0.67, P = 0.62) and ARDs were 22.53/15.13% versus 20.44/14.11% (P = 0.58, P = 0.68) for Dexcom and Enlite, respectively. Both sensors demonstrated significantly lower performance during exercise; median ARD comparison at rest versus exercise for both Dexcom and Enlite showed a P = 0.02. More data pairs met the ISO criteria for Dexcom and Enlite at rest, 73.6% and 76.9% compared with exercise 48.2% and 53.9%. CONCLUSION: Dexcom and Enlite demonstrated comparable overall performances during rest and physical activity. However, a lower accuracy was observed during exercise for both sensors, necessitating a fine-tuning of their performance with physical activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2015.0394

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 62

Metadata

Authors
Taleb, N., Emami, A., Suppere, C., Messier, V., Legault, L., Chiasson, J.-L., Rabasa-Lhoret, R., & Haidar, A.
Venue
Diabetes Technology & Therapeutics
Published
2016-09
Volume
18
Issue
9
Pages
561-567
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2461542737
Cited by
62
References
3
FWCI
11.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.