CoChat

Limitations of Continuous Glucose Monitor Usage

Anhalt, Henry · 2016 · Diabetes Technology & Therapeutics
Cited by 39

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Much progress has been made in diabetes treatments since the first dose of insulin was administered in 1921. However, a truly transformational moment in diabetes care occurred when urine testing gave way to capillary blood home glucose monitoring. As improvements were made to these devices, continuous glucose monitoring (CGM) was introduced. The advantages of experiential learnings gleaned from seeing continuous real-time data have been borne out in numerous peer-reviewed journals. Limitations to use of CGM include patient's level of numeracy and literacy, development of alarm fatigue, interfering substances leading to erroneous readings, high rates of discontinuation, and poor reimbursement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2016.0011

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Anhalt, H.
Venue
Diabetes Technology & Therapeutics
Published
2016-03
Volume
18
Issue
3
Pages
115-117
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2299876101
Cited by
39
References
9
FWCI
4.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.