CGM, Pregnancy, and Remote Monitoring
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The glycemic goals of pregnancy are very narrow to reduce excess risks for numerous maternal and fetal complications. Continuous glucose monitors (CGMs) may help women achieve glucose goals and reduce hypoglycemia. CGM use has been found to be safe and effective in pregnancies associated with diabetes. CGM use can accurately identify glycemic patterns among women with and without diabetes in pregnancy. The data on the effects of CGM use on maternal and fetal outcomes are conflicting. Using CGMs in conjunction with continuous subcutaneous insulin infusion therapy in pregnancies complicated by diabetes may improve outcomes. There are limitations of CGM use that affect patients in and outside of pregnancy, as well as specific barriers that only affect pregnant women. Of importance, CGM use does not replace standard clinical care, but may be used an adjunctive tool in pregnancy. CGM remote monitoring in pregnancy is an understudied field. In this study, we review the studies on CGM use in pregnancy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of Treatment of Gestational Diabetes Mellitus on Pregnancy Outcomes
Crowther, C. A., Hiller, J. E., Moss, J. R., McPhee, A. J., Jeffries, W. S., & Robinson, J. S. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042973 · Cited by 3,159
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
The Hyperglycemia and Adverse Pregnancy Outcome Study
Catalano, P. M., McIntyre, H. D., Cruickshank, J. K., McCance, D. R., Dyer, A. R., Metzger, B. E., Lowe, L. P., Trimble, E. R., Coustan, D. R., Hadden, D. R., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1790 · Cited by 954
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Roberge, S., Nicolaides, K., Demers, S., Hyett, J., Chaillet, N., & Bujold, E. (2017) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2016.09.076 · Cited by 679
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Outcomes in Type 1 Diabetic Pregnancies
Jensen, D. M., Damm, P., Moelsted-Pedersen, L., Ovesen, P., Westergaard, J. G., Moeller, M., & Beck-Nielsen, H. (2004) · Diabetes Care · doi:10.2337/diacare.27.12.2819 · Cited by 486
Managing preexisting diabetes for pregnancy
Kitzmiller, J. L., Block, J. M., Brown, F. M., Catalano, P. M., Conway, D. L., Coustan, D. R., Gunderson, E. P., Herman, W. H., Hoffman, L. D., Inturrisi, M., et al. (2008) · Diabetes Care · doi:10.2337/dc08-9020 · Cited by 476
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
Cited by
Continuous glucose monitors and automated insulin dosing systems in the hospital consensus guideline
Galindo, R. J., Umpierrez, G. E., Rushakoff, R. J., Basu, A., Lohnes, S., Nichols, J. H., Spanakis, E. K., Espinoza, J., Palermo, N. E., Awadjie, D. G., et al. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820954163 · Cited by 170
Guo, H., Zhang, Y., Li, P., Zhou, P., Chen, L.-M., & Li, S.-Y. (2019) · Journal of Endocrinological Investigation · doi:10.1007/s40618-018-0975-0 · Cited by 140
Arnaert, A., Ponzoni, N., Debe, Z., Meda, M. M., Nana, N. G., & Arnaert, S. (2019) · DIGITAL HEALTH · doi:10.1177/2055207619892756 · Cited by 37
Márquez-Pardo, R., Torres-Barea, I., Córdoba-Doña, J.-A., Cruzado-Begines, C., García-García-Doncel, L., Aguilar-Diosdado, M., & Baena-Nieto, M.-G. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0319 · Cited by 29
“To date, there have been only a few published studies evaluating the usefulness of CGM after GDM diagnosis 24–26 ; furthermore, the homogeneous characteristics of the sample and the high number of patients add value to our results, unlike most of the few studies published on CGM for GDM.”
Nichols, C. R., & Cohen, A. K. (2021) · Journal of Public Health Policy · doi:10.1057/s41271-020-00264-9 · Cited by 12
Metadata
- Authors
- Polsky, S., & Garcetti, R.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2017-06
- Volume
- 19
- Issue
- S3
- Pages
- S-49-S-59
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2622620470
- Cited by
- 43
- References
- 21
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CGM, Pregnancy, and Remote Monitoring. https://app.cochat.ai/papers/10.1089/dia.2017.0023
- The paper
- Polsky, S., & Garcetti, R. (2017). CGM, Pregnancy, and Remote Monitoring. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2017.0023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.