CoChat

Overnight Glucose Control with Dual- and Single-Hormone Artificial Pancreas in Type 1 Diabetes with Hypoglycemia Unawareness: A Randomized Controlled Trial

Abitbol, Alexander, Rabasa-Lhoret, Remi, Messier, Virginie, Legault, Laurent, Smaoui, Mohamad, Cohen, Nathan, Haidar, Ahmad · 2018 · Diabetes Technology & Therapeutics
Cited by 39

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The dual-hormone (insulin and glucagon) artificial pancreas may be justifiable in some, but not all, patients. We sought to compare dual- and single-hormone artificial pancreas systems in patients with hypoglycemia unawareness and documented nocturnal hypoglycemia. METHODS: We conducted a randomized crossover trial comparing the efficacy of dual- and single-hormone artificial pancreas systems in controlling plasma glucose levels over the course of one night's sleep. We recruited 18 adult participants with hypoglycemia unawareness and 17 participants with hypoglycemia awareness, all of whom had documented nocturnal hypoglycemia during 2 weeks of screening. Outcomes were calculated using plasma glucose. RESULTS: In participants with hypoglycemia unawareness, the median (interquartile range [IQR]) percentage of time that plasma glucose was below 4.0 mmol/L was 0% (0-0) on dual-hormone artificial pancreas nights and 0% (0-10) on single-hormone artificial pancreas nights (P = 0.20). Additionally, participants with hypoglycemia unawareness experienced two hypoglycemic events (<3.0 mmol/L) on dual-hormone artificial pancreas nights and three hypoglycemic events on single-hormone artificial pancreas nights. In participants with hypoglycemia awareness, the median (IQR) percentage of time that plasma glucose was below 4.0 mmol/L was 0% (0-0) on both dual- and single-hormone artificial pancreas nights. Hypoglycemia awareness participants experienced zero hypoglycemic events on dual-hormone artificial pancreas nights and one event on single-hormone artificial pancreas nights. DISCUSSION: In this study, dual-hormone and single-hormone systems performed equally well in preventing nocturnal hypoglycemia in participants with hypoglycemia unawareness. Longer studies over the course of multiple days and nights may be needed to explore possible specific benefits in this population. ClinicalTrials.gov No. NCT02282254.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2017.0353

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 39

Metadata

Authors
Abitbol, A., Rabasa-Lhoret, R., Messier, V., Legault, L., Smaoui, M., Cohen, N., & Haidar, A.
Venue
Diabetes Technology & Therapeutics
Published
2018-03
Volume
20
Issue
3
Pages
189-196
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2785508426
Cited by
39
References
10
FWCI
3.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Overnight Glucose Control with Dual- and Single-Hormone Artificial Pancreas in Type 1 Diabetes with Hypoglycemia Unawareness: A Randomized Controlled Trial. https://app.cochat.ai/papers/10.1089/dia.2017.0353
The paper
Abitbol, A., Rabasa-Lhoret, R., Messier, V., Legault, L., Smaoui, M., Cohen, N., & Haidar, A. (2018). Overnight Glucose Control with Dual- and Single-Hormone Artificial Pancreas in Type 1 Diabetes with Hypoglycemia Unawareness: A Randomized Controlled Trial. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2017.0353

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.