Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 490

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Universal Real-Time PCR for the Detection and Quantification of Adeno-Associated Virus Serotype 2-Derived Inverted Terminal Repeat Sequences

Aurnhammer, Christine, Haase, Maren, Muether, Nadine, Hausl, Martin, Rauschhuber, Christina, Huber, Ingrid, Nitschko, Hans, Busch, Ulrich, Sing, Andreas, Ehrhardt, Anja, Baiker, Armin·2012·Human Gene Therapy Methods

Abstract

Viral vectors based on various naturally occurring adeno-associated virus (AAV) serotypes are among the most promising tools in human gene therapy. For the production of recombinant AAV (rAAV) vectors, researchers are focusing predominantly on cross-packaging an artificial AAV genome based on serotype 2 (AAV2) into capsids derived from other serotypes. Within the packaged genome the inverted terminal repeats (ITRs) are the only cis-acting viral elements required for rAAV vector generation and depict the lowest common denominator of all AAV2-derived vector genomes. Up to now, no quantitative PCR (qPCR) for the detection and quantification of AAV2 ITRs could be established because of their extensive secondary hairpin structure formation. Current qPCR-based methods are therefore targeting vector-encoded transgenes or regulatory elements. Herein we establish a molecular biological method that allows accurate and reproducible quantification of AAV2 genomes on the basis of an AAV2 ITR sequence-specific qPCR. Primers and labeled probe are located within the ITR sequence and have been designed to detect both wild-type AAV2 and AAV2-based vectors. This method is suitable for detecting single-stranded DNA derived from AAV2 vector particles and double-stranded DNA derived from vector plasmids. The limit of detection has been determined as 50 ITR sequence copies per reaction, by comparison with a plasmid standard. In conclusion, this method describes the first qPCR system facilitating the detection and quantification of AAV2 ITR sequences. Because this method can be used universally for all AAV2 genome-based vectors, it will significantly simplify rAAV2 vector titrations in the future. Aurnhammer and colleagues have developed a quantitative PCR method for accurate, sensitive, and reproducible quantification of adeno-associated virus type 2 (AAV2) genomes based on amplifying sequences within the inverted terminal repeat sequences. This method can detect both wild-type and recombinant AAV2 vectors, and is suitable for single- and double-stranded DNA derived from either vector particles or plasmids.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/hgtb.2011.034

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 2

  1. 10.1093/nar/11.4.999 · doi:10.1093/nar/11.4.999
  2. Knipe D.M., 2001, Fundamental Virology

Cited by

See all 490

Metadata

Authors
Aurnhammer, C., Haase, M., Muether, N., Hausl, M., Rauschhuber, C., Huber, I., Nitschko, H., Busch, U., Sing, A., Ehrhardt, A., & Baiker, A.
Venue
Human Gene Therapy Methods
Published
2012-02
Volume
23
Issue
1
Pages
18-28
ISSN
  • 1946-6536 (ISSN-L)
  • 1946-6544
OpenAlex
W1990559406
Cited by
490
References
32
FWCI
6.91
Type
journal article
Language
en
Open access
closed
Licence
www.liebertpub.com/nv/resources-tools/text-and-data-mining-policy/121/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.