The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Polymer Scaffolds Fabricated with Pore-Size Gradients as a Model for Studying the Zonal Organization within Tissue-Engineered Cartilage Constructs
Abstract
The zonal organization of cells and extracellular matrix (ECM) constituents within articular cartilage is important for its biomechanical function in diarthroidal joints. Tissue-engineering strategies adopting porous three-dimensional (3D) scaffolds offer significant promise for the repair of articular cartilage defects, yet few approaches have accounted for the zonal structural organization as in native articular cartilage. In this study, the ability of anisotropic pore architectures to influence the zonal organization of chondrocytes and ECM components was investigated. Using a novel 3D fiber deposition (3DF) technique, we designed and produced 100% interconnecting scaffolds containing either homogeneously spaced pores (fiber spacing, 1 mm; pore size, about 680 microm in diameter) or pore-size gradients (fiber spacing, 0.5-2.0 mm; pore size range, about 200-1650 microm in diameter), but with similar overall porosity (about 80%) and volume fraction available for cell attachment and ECM formation. In vitro cell seeding showed that pore-size gradients promoted anisotropic cell distribution like that in the superficial, middle, and lower zones of immature bovine articular cartilage, irrespective of dynamic or static seeding methods. There was a direct correlation between zonal scaffold volume fraction and both DNA and glycosaminoglycan (GAG) content. Prolonged tissue culture in vitro showed similar inhomogeneous distributions of zonal GAG and collagen type II accumulation but not of GAG:DNA content, and levels were an order of magnitude less than in native cartilage. In this model system, we illustrated how scaffold design and novel processing techniques can be used to develop anisotropic pore architectures for instructing zonal cell and tissue distribution in tissue-engineered cartilage constructs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scaffolds in tissue engineering bone and cartilage
Hutmacher, D. W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00121-6 · Cited by 4,994
FARNDALE, R., BUTTLE, D., & BARRETT, A. (1986) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(86)90306-5 · Cited by 3,312
Hunziker, E. B. (2002) · Osteoarthritis and Cartilage · doi:10.1053/joca.2002.0801 · Cited by 1,975
Cell origin and differentiation in the repair of full-thickness defects of articular cartilage.
Shapiro, F., Koide, S., & Glimcher, M. J. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199304000-00009 · Cited by 1,253
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060
Vunjak‐Novakovic, G., Martin, I., Obradovic, B., Treppo, S., Grodzinsky, A. J., Langer, R., & Freed, L. E. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170119 · Cited by 743
Woodfield, T. B. F., Malda, J., de Wijn, J., Péters, F., Riesle, J., & van Blitterswijk, C. A. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.056 · Cited by 618
Self-citationHollander, A. P., Heathfield, T. F., Webber, C., Iwata, Y., Bourne, R., Rorabeck, C., & Poole, A. R. (1994) · Journal of Clinical Investigation · doi:10.1172/jci117156 · Cited by 611
Self-citationDynamic Cell Seeding of Polymer Scaffolds for Cartilage Tissue Engineering
Vunjak‐Novakovic, G., Obradovic, B., Martin, I., Bursac, P. M., Langer, R., & Freed, L. E. (1998) · Biotechnology Progress · doi:10.1021/bp970120j · Cited by 551
Quantitative structural organization of normal adult human articular cartilage
Hunziker, E. B., Quinn, T. M., & Häuselmann, H.-J. (2002) · Osteoarthritis and Cartilage · doi:10.1053/joca.2002.0814 · Cited by 502
Cited by
Pham, Q. P., Sharma, U., & Mikos, A. G. (2006) · Biomacromolecules · doi:10.1021/bm060680j · Cited by 956
Chung, C., & Burdick, J. A. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.027 · Cited by 760
Oh, S. H., Park, I. K., Kim, J. M., & Lee, J. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.024 · Cited by 713
Biomaterials for articular cartilage tissue engineering: Learning from biology
Armiento, A. R., Stoddart, M. J., Alini, M., & Eglin, D. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.021 · Cited by 579
Sobral, J. M., Caridade, S. G., Sousa, R. A., Mano, J. F., & Reis, R. L. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.11.003 · Cited by 561
Metadata
- Authors
- Woodfield, T. B. F., Blitterswijk, C. A. V., Wijn, J. D., Sims, T. J., Hollander, A. P., & Riesle, J.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2005-09
- Volume
- 11
- Issue
- 9-10
- Pages
- 1297-1311
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2121275713
- Cited by
- 275
- References
- 35
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polymer Scaffolds Fabricated with Pore-Size Gradients as a Model for Studying the Zonal Organization within Tissue-Engineered Cartilage Constructs. https://app.cochat.ai/papers/10.1089/ten.2005.11.1297
- The paper
- Woodfield, T. B. F., Blitterswijk, C. A. V., Wijn, J. D., Sims, T. J., Hollander, A. P., & Riesle, J. (2005). Polymer Scaffolds Fabricated with Pore-Size Gradients as a Model for Studying the Zonal Organization within Tissue-Engineered Cartilage Constructs. Tissue Engineering. https://doi.org/10.1089/ten.2005.11.1297
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.