The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Endothelialized Microvasculature Based on a Biodegradable Elastomer
Abstract
Vital organs maintain dense microvasculature to sustain the proper function of their cells. For tissue- engineered organs to function properly, artificial capillary networks must be developed. We have microfabricated capillary networks with a biodegradable and biocompatible elastomer, poly(glycerol sebacate) (PGS). We etched capillary patterns onto silicon wafers by standard micro-electromechanical systems (MEMS) techniques. The resultant silicon wafers served as micromolds for the devices. We bond the patterned PGS film with a flat film to create capillary networks that were perfused with a syringe pump at a physiological flow rate. The devices were endothelialized under flow conditions, and part of the lumens reached confluence within 14 days of culture. This approach may lead to tissue-engineered microvasculature that is critical in vital organs engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Self-citationPoly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Vacanti, J. P., & Langer, R. (1999) · The Lancet · doi:10.1016/s0140-6736(99)90247-7 · Cited by 1,323
Self-citationA tough biodegradable elastomer
Wang, Y., Ameer, G. A., Sheppard, B. J., & Langer, R. (2002) · Nature Biotechnology · doi:10.1038/nbt0602-602 · Cited by 1,314
Self-citationSELF-REGULATION OF GROWTH IN THREE DIMENSIONS
Folkman, J., & Hochberg, M. (1973) · The Journal of Experimental Medicine · doi:10.1084/jem.138.4.745 · Cited by 829
Components for integrated poly(dimethylsiloxane) microfluidic systems
Ng, J. M. K., Gitlin, I., Stroock, A. D., & Whitesides, G. M. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200210)23:20<3461::aid-elps3461>3.0.co;2-8 · Cited by 626
Implantable biohybrid artificial organs
Colton, C. (1995) · Cell Transplantation · doi:10.1016/0963-6897(95)00025-s · Cited by 586
Kim, S. S., Utsunomiya, H., Koski, J. A., Wu, B. M., Cima, M. J., Sohn, J., Mukai, K., Griffith, L. G., & Vacanti, J. P. (1998) · Annals of Surgery · doi:10.1097/00000658-199807000-00002 · Cited by 451
Self-citationIn vivo degradation characteristics of poly(glycerol sebacate)
Wang, Y., Kim, Y. M., & Langer, R. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10534 · Cited by 389
Self-citationTissue Engineering: The Challenges Ahead
Langer, R. S., & Vacanti, J. P. (1999) · Scientific American · doi:10.1038/scientificamerican0499-86 · Cited by 362
Self-citationMicrofabrication Technology for Vascularized Tissue Engineering
Borenstein, J. T., Terai, H., King, K. R., Weinberg, E. J., Kaazempur-Mofrad, M. R., & Vacanti, J. P. (2002) · Biomedical Microdevices · doi:10.1023/a:1016040212127 · Cited by 361
Self-citationSilicon Micromachining to Tissue Engineer Branched Vascular Channels for Liver Fabrication
Kaihara, S., Borenstein, J., Koka, R., Lalan, S., Ochoa, E. R., Ravens, M., Pien, H., Cunningham, B., & Vacanti, J. P. (2000) · Tissue Engineering · doi:10.1089/107632700320739 · Cited by 323
Self-citationIn Vitro Organogenesis of Liver Tissuea
GRIFFITH, L. G., WU, B., CIMA, M. J., POWERS, M. J., CHAIGNAUD, B., & VACANTI, J. P. (1997) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1997.tb52212.x · Cited by 170
Self-citationComplex Systems Science in Biomedicine
(2006) · Springer eBooks · doi:10.1007/978-0-387-33532-2 · Cited by 168
Computational modeling of blood flow and rheology in fractal microvascular networks
Mofrad, M. R. K., Vacanti, J. P., & Kamm, R. D. (2001) · Elsevier eBooks · doi:10.1016/b978-008043944-0/50789-7 · Cited by 16
Self-citation
Cited by
Microscale technologies for tissue engineering and biology
Khademhosseini, A., Langer, R., Borenstein, J., & Vacanti, J. P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507681102 · Cited by 1,558
Self-citationControlling the Porosity and Microarchitecture of Hydrogels for Tissue Engineering
Annabi, N., Nichol, J. W., Zhong, X., Ji, C., Koshy, S., Khademhosseini, A., & Dehghani, F. (2010) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0639 · Cited by 1,308
Vascularization is the key challenge in tissue engineering
Novosel, E. C., Kleinhans, C., & Kluger, P. J. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.03.004 · Cited by 1,062
Stem cell-based tissue engineering with silk biomaterials
Wang, Y., Kim, H.-J., Vunjak-Novakovic, G., & Kaplan, D. L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.07.008 · Cited by 968
Self-citationEngineering Hydrogels as Extracellular Matrix Mimics
Geckil, H., Xu, F., Zhang, X., Moon, S., & Demirci, U. (2010) · Nanomedicine · doi:10.2217/nnm.10.12 · Cited by 944
Metadata
- Authors
- Fidkowski, C., Kaazempur-Mofrad, M. R., Borenstein, J., Vacanti, J. P., Langer, R., & Wang, Y.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2005-01
- Volume
- 11
- Issue
- 1-2
- Pages
- 302-309
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2017482231
- Cited by
- 343
- References
- 15
- FWCI
- 16.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.