Mechano-Active Scaffold Design Based on Microporous Poly(L-lactide-co- ε -caprolactone) for Articular Cartilage Tissue Engineering: Dependence of Porosity on Compression Force-Applied Mechanical Behaviors
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
An essential component of functional articular cartilage tissue engineering is a mechano-active scaffold, which responds to applied compression stress and causes little permanent deformation. As the first paper of a series on mechano-active scaffold-based cartilage tissue engineering, this study focused on mechanical responses to various modes of loading of compression forces and subsequent selection of mechano-active scaffolds from the biomechanical viewpoint. Scaffolds made of elastomeric microporous poly(L-lactide-co-epsilon-caprolactone) (PLCL) with open-cell structured pores (300 approximately 500 microm) and with different porosities ranging from 71 to 86% were used. The PLCL sponges and rabbit articular cartilage tissue were subjected to compression/unloading tests (0.1 and 0.005 Hz) at 5 kPa, and stress relaxation tests at 10, 30, and 50% strain. The measurements of the maximum strain under loading and residual strain under unloading for compression tests and the maximum stress and equilibrium stress in the stress relaxation test showed that the lower the porosity, the closer the mechanical properties are to those of native cartilage tissue. Among the PLCL sponges, the sponge with 71% porosity appears to be a suitable cartilage scaffold.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polylactones: 31. Sn(II)octoate-initiated polymerization of L-lactide: a mechanistic study
Kricheldorf, H. R., Kreiser-Saunders, I., & Boettcher, C. (1995) · Polymer · doi:10.1016/0032-3861(95)93928-f · Cited by 411
(Co)polymers of L‐lactide, 2. Mechanical properties
Grijpma, D. W., & Pennings, A. J. (1994) · Macromolecular Chemistry and Physics · doi:10.1002/macp.1994.021950516 · Cited by 191
Jeong, S. I., Kim, B.-S., Lee, Y. M., Ihn, K. J., Kim, S. H., & Kim, Y. H. (2004) · Biomacromolecules · doi:10.1021/bm049921i · Cited by 182
Self-citationManufacture of elastic biodegradable PLCL scaffolds for mechano-active vascular tissue engineering
Jeong, S. I., Kim, S. H., Kim, Y. H., Jung, Y., Kwon, J. H., Kim, B.-S., & Lee, Y. M. (2004) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856204323046906 · Cited by 181
Self-citation
Cited by
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033
Matrices and scaffolds for delivery of bioactive molecules in bone and cartilage tissue engineering
Lee, S.-H., & Shin, H. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.016 · Cited by 706
Strategic Design and Fabrication of Engineered Scaffolds for Articular Cartilage Repair
Izadifar, Z., Chen, X., & Kulyk, W. (2012) · Journal of Functional Biomaterials · doi:10.3390/jfb3040799 · Cited by 203
“mechanical properties, with those of lower porosity best resembling the performance of rabbit articular cartilage in compression and stress relaxation tests [111].”
BackgroundXie, J., Han, Z., Naito, M., Maeyama, A., Kim, S. H., Kim, Y. H., & Matsuda, T. (2010) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31627 · Cited by 47
Self-citationPerpelek, M., Tamburaci, S., Aydemir, S., Tihminlioglu, F., Baykara, B., Karakasli, A., & Havitcioglu, H. (2021) · Biomedical Materials · doi:10.1088/1748-605x/ac2352 · Cited by 27
“%) to better mimic the natural cartilage structure [32].”
Metadata
- Authors
- Xie, J., Ihara, M., Jung, Y., Kwon, I. K., Kim, S. H., Kim, Y. H., & Matsuda, T.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2006-03
- Volume
- 12
- Issue
- 3
- Pages
- 449-458
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2024255043
- Cited by
- 77
- References
- 4
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechano-Active Scaffold Design Based on Microporous Poly(L-lactide-co- ε -caprolactone) for Articular Cartilage Tissue Engineering: Dependence of Porosity on Compression Force-Applied Mechanical Behaviors. https://app.cochat.ai/papers/10.1089/ten.2006.12.449
- The paper
- Xie, J., Ihara, M., Jung, Y., Kwon, I. K., Kim, S. H., Kim, Y. H., & Matsuda, T. (2006). Mechano-Active Scaffold Design Based on Microporous Poly(L-lactide-co- ε -caprolactone) for Articular Cartilage Tissue Engineering: Dependence of Porosity on Compression Force-Applied Mechanical Behaviors. Tissue Engineering. https://doi.org/10.1089/ten.2006.12.449
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.