CoChat

In Vivo Selection of Biocompatible Alginates for Islet Encapsulation and Subcutaneous Transplantation

Vériter, Sophie, Mergen, Julien, Goebbels, Rose-Marie, Aouassar, Najima, Grégoire, Charles, Jordan, Bénédicte, Levêque, Philippe, Gallez, Bernard, Gianello, Pierre, Dufrane, Denis · 2010 · Tissue Engineering Part A
Cited by 97

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Islet encapsulation requires several properties including (1) biocompatibility, (2) immunoprotection, and (3) oxygen diffusion for islet survival and diabetes correction. New chemical alginates were tested in vivo and compared with traditional high-mannuronate and -guluronate alginates. New alginates with coupled peptide sequence (sterile lyophilized high mannuronate [SLM]-RGD3% and sterile lyophilized high guluronate [SLG]-RGD3%), to improve encapsulated cell adherence in the matrix, and alginates with a very low viscosity (VLDM7% and VLDG7%), to reduce implant size by loading a higher number of islets per volume of polymer, were implanted subcutaneously in 70 Wistar rats for comparison with alginates of high viscosity and high content of mannuronic (SLM3%) or guluronic acids (SLG3%). Permeability of alginates to 36-, 75-, and 150-kDa lectins coupled to fluorescein isothiocynate was quantified before implantation and at 2, 4, and 12 weeks after implantation. Biocompatibility (fibrosis, graft stability, immunologic infiltration by CD3/CD68 cells, and neovascularization) was assessed at each explantation time. Permeability to small molecules was found for all alginates. Impermeability to 150-kDa molecules, such as IgG, was observed only for SLM3% before implantation and was maintained up to 12 weeks after implantation. SLM3% and SLG3% demonstrated better graft stability with lower CD3/CD68 recruitment and fibrosis than the other alginates. SLM3% induced a significantly higher angiogenesis and maintained oxygen pressure at approximately 40 mm Hg for up to 4 weeks after implantation as measured by in vivo electronic paramagnetic resonance oximetry. SLM-encapsulated pig islets implanted subcutaneously in rats demonstrated no inflammatory/immunologic reactions and islets functioned for up to 60 days without immunosuppression. A traditional alginate made of high mannuronic content (SLM3%) is an adapted material to immunoprotect islets in subcutaneous tissue. No improvement was found with lower viscosity and use of GRGDSP-peptide sequence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.tea.2009.0286

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Vériter, S., Mergen, J., Goebbels, R.-M., Aouassar, N., Grégoire, C., Jordan, B., Levêque, P., Gallez, B., Gianello, P., & Dufrane, D.
Venue
Tissue Engineering Part A
Published
2010-05
Volume
16
Issue
5
Pages
1503-1513
ISSN
  • 1937-3341 (ISSN-L)
  • 1937-335X
OpenAlex
W2040911802
Cited by
97
References
7
FWCI
6.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.