The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Scaffold Fiber Diameter Regulates Human Tendon Fibroblast Growth and Differentiation
Open accessAbstract
The diameter of collagen fibrils in connective tissues, such as tendons and ligaments is known to decrease upon injury or with age, leading to inferior biomechanical properties and poor healing capacity. This study tests the hypotheses that scaffold fiber diameter modulates the response of human tendon fibroblasts, and that diameter-dependent cell responses are analogous to those seen in healthy versus healing tissues. Particularly, the effect of the fiber diameter (320 nm, 680 nm, and 1.80 μm) on scaffold properties and the response of human tendon fibroblasts were determined over 4 weeks of culture. It was observed that scaffold mechanical properties, cell proliferation, matrix production, and differentiation were regulated by changes in the fiber diameter. More specifically, a higher cell number, total collagen, and proteoglycan production were found on the nanofiber scaffolds, while microfibers promoted the expression of phenotypic markers of tendon fibroblasts, such as collagen I, III, V, and tenomodulin. It is possible that the nanofiber scaffolds of this study resemble the matrix in a state of injury, stimulating the cells for matrix deposition as part of the repair process, while microfibers represent the healthy matrix with micron-sized collagen bundles, thereby inducing cells to maintain the fibroblastic phenotype. The results of this study demonstrate that controlling the scaffold fiber diameter is critical in the design of scaffolds for functional and guided connective tissue repair, and provide new insights into the role of matrix parameters in guiding soft tissue healing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Topographical control of cell behaviour: II. multiple grooved substrata
Clark, P., Connolly, P., Curtis, A. S. G., Dow, J. A. T., & Wilkinson, C. D. W. (1990) · Development · doi:10.1242/dev.108.4.635 · Cited by 682
Type V collagen controls the initiation of collagen fibril assembly
Wenstrup, R. J., Florer, J. B., Brunskill, E. W., Bell, S. M., Chervoneva, I., & Birk, D. E. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m409622200 · Cited by 545
Collagen Fibril Diameters in the Rabbit Medial Collateral Ligament Scar: A Longer Term Assessment
Frank, C., McDonald, D., & Shrive, N. (1997) · Connective Tissue Research · doi:10.3109/03008209709160226 · Cited by 115 · cited 1×
“5,6 Soft tissue healing often results in the formation of a scar tissue, which is compositionally and mechanically inferior to the native tendon or ligament, 7 resulting in as high as 94% recurrent tears in some cases.”
Cited by
Kular, J. K., Basu, S., & Sharma, R. I. (2014) · Journal of Tissue Engineering · doi:10.1177/2041731414557112 · Cited by 559
Functional Attachment of Soft Tissues to Bone: Development, Healing, and Tissue Engineering
Lu, H. H., & Thomopoulos, S. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124656 · Cited by 447
Self-citationDesign Challenges in Polymeric Scaffolds for Tissue Engineering
Echeverria Molina, M. I., Malollari, K. G., & Komvopoulos, K. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.617141 · Cited by 397
The guidance of stem cell differentiation by substrate alignment and mechanical stimulation
Subramony, S. D., Dargis, B. R., Castillo, M., Azeloglu, E. U., Tracey, M. S., Su, A., & Lu, H. H. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.11.012 · Cited by 274
Self-citationScaffold-Mediated Immunoengineering as Innovative Strategy for Tendon Regeneration
Russo, V., El Khatib, M., Prencipe, G., Cerveró-Varona, A., Citeroni, M. R., Mauro, A., Berardinelli, P., Faydaver, M., Haidar-Montes, A. A., Turriani, M., et al. (2022) · Cells · doi:10.3390/cells11020266 · Cited by 49
Metadata
- Authors
- Erisken, C., Zhang, X., Moffat, K. L., Levine, W. N., & Lu, H. H.
- Venue
- Tissue Engineering Part A
- Publisher
- SAGE Publications
- Published
- 2013-02
- Volume
- 19
- Issue
- 3-4
- Pages
- 519-528
- ISSN
- 1937-3341 (ISSN-L)
- 1937-335X
- OpenAlex
- W2029661630
- Cited by
- 173
- References
- 3
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Scaffold Fiber Diameter Regulates Human Tendon Fibroblast Growth and Differentiation. https://app.cochat.ai/papers/10.1089/ten.tea.2012.0072
- The paper
- Erisken, C., Zhang, X., Moffat, K. L., Levine, W. N., & Lu, H. H. (2013). Scaffold Fiber Diameter Regulates Human Tendon Fibroblast Growth and Differentiation. Tissue Engineering Part A. https://doi.org/10.1089/ten.tea.2012.0072
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.