CoChat

Three-Dimensional-Engineered Matrix to Study Cancer Stem Cells and Tumorsphere Formation: Effect of Matrix Modulus

Open access
Yang, Xiaoming, Sarvestani, Samaneh K., Moeinzadeh, Seyedsina, He, Xuezhong, Jabbari, Esmaiel · 2013 · Tissue Engineering Part A
Cited by 80

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Maintenance of cancer stem cells (CSCs) is regulated by the tumor microenvironment. Synthetic hydrogels provide the flexibility to design three-dimensional (3D) matrices to isolate and study individual factors in the tumor microenvironment. The objective of this work was to investigate the effect of matrix modulus on tumorsphere formation by breast cancer cells and maintenance of CSCs in an inert microenvironment without the interference of other factors. In that regard, 4T1 mouse breast cancer cells were encapsulated in inert polyethylene glycol diacrylate hydrogels and the effect of matrix modulus on tumorsphere formation and expression of CSC markers was investigated. The gel modulus had a strong effect on tumorsphere formation and the effect was bimodal. Tumorsphere formation and expression of CSC markers peaked after 8 days of culture. At day 8, as the matrix modulus was increased from 2.5 kPa to 5.3, 26.1, and 47.1 kPa, the average tumorsphere size changed from 37±6 μm to 57±6, 20±4, and 12±2 μm, respectively; cell number density in the gel changed from 0.8±0.1×10⁵ cells/mL to 1.7±0.2×10⁵, 0.4±0.1×10⁵, and 0.2±0.1×10⁵ cells/mL after initial encapsulation of 0.14×10⁵ cells/mL; and the expression of CD44 breast CSC marker changed from 17±4-fold to 38±9-, 3±1-, and 2±1-fold increase compared with the initial level. Similar results were obtained with MCF7 human breast carcinoma cells. Mouse 4T1 and human MCF7 cells encapsulated in the gel with 5.3 kPa modulus formed the largest tumorspheres and highest density of tumorspheres, and had highest expression of breast CSC markers CD44 and ABCG2. The inert polyethylene glycol hydrogel can be used as a model-engineered 3D matrix to study the role of individual factors in the tumor microenvironment on tumorigenesis and maintenance of CSCs without the interference of other factors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.tea.2012.0333

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Yang, X., Sarvestani, S. K., Moeinzadeh, S., He, X., & Jabbari, E.
Venue
Tissue Engineering Part A
Published
2013-03
Volume
19
Issue
5-6
Pages
669-684
ISSN
  • 1937-3341 (ISSN-L)
  • 1937-335X
OpenAlex
W2098950460
Cited by
80
References
8
FWCI
2.57
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.