Technical Evaluation of Five Glucose Meters With Data Management Capabilities
The DOI matches its Crossref record.
Abstract
Technical performance and data management features are prominent criteria in the selection of an appropriate meter for a point-of-care glucose testing program. We evaluated the technical performance of 5 currently available glucose meters with data management capabilities. The performance of all 5 meters was technically equivalent. Linear regression slopes vs the reference method are in the range of 0.94 to 1.02 and indicate correlation more to plasma values than to whole blood values. The percentage of glucose meter results within +/- 15% of the laboratory value was at least 90%; however, the percentage within +/- 10% was 75% to 87% for most meters. Within-day and between-day precision ranged from 2% to 5% coefficient of variation. Evaluation of linearity with glucose-spiked venous specimens demonstrated that the linearity of each meter agreed with the manufacturer's stated range in most cases. Meter glucose values tended to bias negative as the hematocrit increased, an effect that may be more pronounced at higher glucose concentrations. No volume effects were noted between 5 microL and 40 microL. The results suggest that all meters tested will likely satisfy technical performance criteria in a hospital setting and that selection of a system for point-of-care glucose testing will be influenced by the institution's data management requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biosensors in clinical chemistry
D'Orazio, P. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00241-9 · Cited by 524
Approved IFCC recommendation on reporting results for blood glucose (abbreviated)
D'Orazio, P. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.051979 · Cited by 208
Tang, Z., Louie, R. F., Lee, J. H., Lee, D. M., Miller, E. E., & Kost, G. J. (2001) · Critical Care Medicine · doi:10.1097/00003246-200105000-00038 · Cited by 188
Louie, R. F., Tang, Z., Sutton, D. V., Lee, J. H., & Kost, G. J. (2000) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2000-124-0257-pocgt · Cited by 180
Skeie, S., Thue, G., Nerhus, K., & Sandberg, S. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.7.994 · Cited by 131
IFCC recommendation on reporting results for blood glucose
(2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00431-4 · Cited by 110
Performance of a new interference-resistant glucose meter
Vanavanan, S., Santanirand, P., Chaichanajarernkul, U., Chittamma, A., DuBois, J. A., Shirey, T., & Heinz, M. (2010) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.09.010 · Cited by 39
Factors interfering with the accuracy of five blood glucose meters used in Chinese hospitals
Lv, H., Zhang, G., Kang, X., Yuan, H., Lv, Y., Wang, W., & Randall, R. (2013) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.21611 · Cited by 20
Karon, B. S., Meeusen, J. W., & Bryant, S. C. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815602099 · Cited by 16
Metadata
- Authors
- Chance, J. J., Li, D. J., Jones, K. A., Dyer, K. L., & Nichols, J. H.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-04-01
- Volume
- 111
- Issue
- 4
- Pages
- 547-556
- ISSN
- 0002-9173 (ISSN-L)
- 1943-7722
- OpenAlex
- W2316242190
- Cited by
- 48
- References
- 0
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.