Effect of Fit Testing on the Protection Offered by N95 Filtering Facepiece Respirators Against Fine Particles in a Laboratory Setting
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: This study investigated particle-size-selective protection factors (PFs) of four models of N95 filtering facepiece respirators (FFRs) that passed and failed fit testing. Particle size ranges were representative of individual viruses and bacteria (aerodynamic diameter d(a) = 0.04-1.3 μm). METHODS: Standard respirator fit testing was followed by particle-size-selective measurement of PFs while subjects wore N95 FFRs in a test chamber. PF values obtained for all subjects were then compared to those obtained for the subjects who passed the fit testing. RESULTS: Overall fit test passing rate for all four models of FFRs was 67%. Of these, 29% had PFs <10 (the Occupational Safety and Health Administration Assigned Protection Factor designated for this type of respirator). When only subjects that passed fit testing were included, PFs improved with 9% having values <10. On average, the PFs were 1.4 times (29.5/21.5) higher when only data for those who passed fit testing were included. The minimum PFs were consistently observed in the particle size range of 0.08-0.2 μm. CONCLUSIONS: Overall PFs increased when subjects passed fit testing. The results support the value of fit testing but also show for the first time that PFs are dependent on particle size regardless of fit testing status.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803 · cited 1×
“There is much debate in the literature regarding the size of aerosolized particles that may cause viral infection (Roy and Milton, 2004; Tellier, 2006).”
BackgroundInhaling to mitigate exhaled bioaerosols
Edwards, D. A., Man, J. C., Brand, P., Katstra, J. P., Sommerer, K., Stone, H. A., Nardell, E., & Scheuch, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408159101 · Cited by 362
Lee, S.-A., Grinshpun, S. A., & Reponen, T. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men005 · Cited by 235 · cited 11×
“Data include only subject–respirator combinations that passed quantitative fit testing (data for all subjects are published in Lee et al., 2008).”
BackgroundMethodInfluentialSelf-citationLee, S.-A., Adhikari, A., Grinshpun, S. A., McKay, R., Shukla, R., Zeigler, H. L., & Reponen, T. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500330583 · Cited by 73 · cited 5×
“A dehumidifier was used to minimize this effect (Lee et al., 2005b).”
BackgroundMethodResultInfluentialSelf-citationFILTER AND LEAK PENETRATION CHARACTERISTICS OF A DUST AND MIST FILTERING FACEPIECE
Chen, C. C., Ruuskanen, J., Pilacinski, W., & Willeke, K. (1990) · American Industrial Hygiene Association Journal · doi:10.1080/15298669091370275 · Cited by 53
Zhuang, Z., Coffey, C. C., Jensen, P. A., Campbell, D. L., Lawrence, R. B., & Myers, W. R. (2003) · AIHA Journal · doi:10.1080/15428110308984867 · Cited by 53
Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow
(2009) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mep062 · Cited by 42 · cited 1×
“…has been studied in the laboratory using manikins (Hinds and Kraske, 1987; Chen and Willeke, 1990; Chen et al., 1990; Weber et al., 1993; Lee et al., 2005b; Cho et al., 2010), only a few studies have been conducted with human subjects (Holton et al., 1987; Lee et al., 2008; Grinshpun et al., 2009).”
BackgroundSelf-citationField Performance Measurements of Half-Facepiece Respirators—Paint Spraying Operations
Zhuang, Z., & Myers, W. R. (1996) · American Industrial Hygiene Association Journal · doi:10.1080/15428119691015214 · Cited by 20
Cited by
Lee, S.-A., Hwang, D.-C., Li, H.-Y., Tsai, C.-F., Chen, C.-W., & Chen, J.-K. (2016) · Journal of Healthcare Engineering · doi:10.1155/2016/8572493 · Cited by 134
Self-citationO’Kelly, E., Arora, A., Pirog, S., Ward, J., & Clarkson, P. J. (2021) · PLOS ONE · doi:10.1371/journal.pone.0245688 · Cited by 123
“of workplace protection, fit factors have been shown to be an effective method of predicting actual workplace protection [10].”
BackgroundMethod(2012) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mer122 · Cited by 75
Gao, S., Koehler, R. H., Yermakov, M., & Grinshpun, S. A. (2016) · Annals of Occupational Hygiene · doi:10.1093/annhyg/mew006 · Cited by 46
Self-citationComparison of Workplace Protection Factors for Different Biological Contaminants
Cho, K. J., Reponen, T., McKay, R., Dwivedi, A., Adhikari, A., Singh, U., Shukla, R., Jones, S., Jones, G., & Grinshpun, S. A. (2011) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2011.585094 · Cited by 14
Self-citation
Metadata
- Authors
- Reponen, T., Lee, S.-A., Grinshpun, S. A., Johnson, E., & Mckay, R.
- Venue
- Annals of Occupational Hygiene
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-12-20
- Volume
- 55
- Issue
- 3
- Pages
- 264-271
- ISSN
- 0003-4878 (ISSN-L)
- 1475-3162
- OpenAlex
- W2145950870
- Cited by
- 48
- References
- 8
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Fit Testing on the Protection Offered by N95 Filtering Facepiece Respirators Against Fine Particles in a Laboratory Setting. https://app.cochat.ai/papers/10.1093/annhyg/meq085
- The paper
- Reponen, T., Lee, S.-A., Grinshpun, S. A., Johnson, E., & Mckay, R. (2011). Effect of Fit Testing on the Protection Offered by N95 Filtering Facepiece Respirators Against Fine Particles in a Laboratory Setting. Annals of Occupational Hygiene. https://doi.org/10.1093/annhyg/meq085
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.