The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Bleeding management with fibrinogen concentrate targeting a high-normal plasma fibrinogen level: a pilot study
Open accessAbstract
BACKGROUND: Bleeding diathesis after aortic valve operation and ascending aorta replacement (AV-AA) is managed with fresh-frozen plasma (FFP) and platelet concentrates. The aim was to compare haemostatic effects of conventional transfusion management and FIBTEM (thromboelastometry test)-guided fibrinogen concentrate administration. METHODS: A blood products transfusion algorithm was developed using retrospective data from 42 elective patients (Group A). Two units of platelet concentrate were transfused after cardiopulmonary bypass, followed by 4 u of FFP if bleeding persisted, if platelet count was < or =100 x 10(3) microl(-1) when removing the aortic clamp, and vice versa if platelet count was >100 x 10(3) microl(-1). The trigger for each therapy step was > or =60 g blood absorbed from the mediastinal wound area by dry swabs in 5 min. Assignment to two prospective groups was neither randomized nor blinded; Group B (n=5) was treated according to the algorithm, Group C (n=10) received fibrinogen concentrate (Haemocomplettan P/Riastap, CSL Behring, Marburg, Germany) before the algorithm-based therapy. RESULTS: A mean of 5.7 (0.7) g fibrinogen concentrate decreased blood loss to below the transfusion trigger level in all Group C patients. Group C had reduced transfusion [mean 0.7 (range 0-4) u vs 8.5 (5.3) in Group A and 8.2 (2.3) in Group B] and reduced postoperative bleeding [366 (199) ml vs 793 (560) in Group A and 716 (219) in Group B]. CONCLUSIONS: In this pilot study, FIBTEM-guided fibrinogen concentrate administration was associated with reduced transfusion requirements and 24 h postoperative bleeding in patients undergoing AV-AA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thromboelastography-Guided Transfusion Algorithm Reduces Transfusions in Complex Cardiac Surgery
Shore-Lesserson, L., Manspeizer, H. E., DePerio, M., Francis, S., Vela-Cantos, F., & Ergin, M. A. (1999) · Anesthesia & Analgesia · doi:10.1097/00000539-199902000-00016 · Cited by 845
Guidelines for the use of fresh‐frozen plasma, cryoprecipitate and cryosupernatant
British Committee for Standards in Haematology, B. T. T. F. (. D., O'Shaughnessy, D. F., Atterbury, C., Bolton Maggs, P., Murphy, M., Thomas, D., Yates, S., & Williamson, L. M. (2004) · British Journal of Haematology · doi:10.1111/j.1365-2141.2004.04972.x · Cited by 840
The decrease of fibrinogen is an early predictor of the severity of postpartum hemorrhage
CHARBIT, B., MANDELBROT, L., SAMAIN, E., BARON, G., HADDAOUI, B., KEITA, H., SIBONY, O., MAHIEU‐CAPUTO, D., HURTAUD‐ROUX, M. F., HUISSE, M. G., et al. (2007) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2007.02297.x · Cited by 762
Thromboembolic Adverse Events After Use of Recombinant Human Coagulation Factor VIIa
O’Connell, K. A. (2006) · JAMA · doi:10.1001/jama.295.3.293 · Cited by 671
Levi, M., Cromheecke, M. E., de Jonge, E., Prins, M. H., de Mol, B. J., Briët, E., & Büller, H. R. (1999) · The Lancet · doi:10.1016/s0140-6736(99)01264-7 · Cited by 545
Khan, H., Belsher, J., Yilmaz, M., Afessa, B., Winters, J. L., Moore, S. B., Hubmayr, R. D., & Gajic, O. (2007) · Chest · doi:10.1378/chest.06-3048 · Cited by 382
Chowdhury, P., Saayman, A. G., Paulus, U., Findlay, G. P., & Collins, P. W. (2004) · British Journal of Haematology · doi:10.1111/j.1365-2141.2004.04868.x · Cited by 381
The platelet function defect of cardiopulmonary bypass [see comments]
Kestin, A., Valeri, C., Khuri, S., Loscalzo, J., Ellis, P., MacGregor, H., Birjiniuk, V, Ouimet, H., Pasche, B., & Nelson, M. (1993) · Blood · doi:10.1182/blood.v82.1.107.bloodjournal821107 · Cited by 323
Spiess, B. D., Royston, D., Levy, J. H., Fitch, J., Dietrich, W., Body, S., Murkin, J., & Nadel, A. (2004) · Transfusion · doi:10.1111/j.1537-2995.2004.03322.x · Cited by 319
Nuttall, G. A., Oliver, W. C., Santrach, P. J., Bryant, S., Dearani, J. A., Schaff, H. V., & Ereth, M. H. (2001) · Anesthesiology · doi:10.1097/00000542-200105000-00014 · Cited by 285
Cited by
Management of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Self-citationSchöchl, H., Nienaber, U., Hofer, G., Voelckel, W., Jambor, C., Scharbert, G., Kozek-Langenecker, S., & Solomon, C. (2010) · Critical Care · doi:10.1186/cc8948 · Cited by 637
Self-citationWikkelsø, A., Wetterslev, J., Møller, A. M., & Afshari, A. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007871.pub3 · Cited by 400
Schöchl, H., Nienaber, U., Maegele, M., Hochleitner, G., Primavesi, F., Steitz, B., Arndt, C., Hanke, A., Voelckel, W., & Solomon, C. (2011) · Critical Care · doi:10.1186/cc10078 · Cited by 398
Self-citationBolliger, D., Seeberger, M. D., & Tanaka, K. A. (2012) · Transfusion Medicine Reviews · doi:10.1016/j.tmrv.2011.07.005 · Cited by 397
Self-citation
Metadata
- Authors
- Rahe-Meyer, N., Pichlmaier, M., Haverich, A., Solomon, C., Winterhalter, M., Piepenbrock, S., & Tanaka, K. A.
- Venue
- British Journal of Anaesthesia
- Publisher
- Elsevier BV
- Published
- 2009-06
- Volume
- 102
- Issue
- 6
- Pages
- 785-792
- ISSN
- 0007-0912 (ISSN-L)
- OpenAlex
- W2121864664
- Cited by
- 261
- References
- 25
- FWCI
- 17.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bleeding management with fibrinogen concentrate targeting a high-normal plasma fibrinogen level: a pilot study. https://app.cochat.ai/papers/10.1093/bja/aep089
- The paper
- Rahe-Meyer, N., Pichlmaier, M., Haverich, A., Solomon, C., Winterhalter, M., Piepenbrock, S., & Tanaka, K. A. (2009). Bleeding management with fibrinogen concentrate targeting a high-normal plasma fibrinogen level: a pilot study. British Journal of Anaesthesia. https://doi.org/10.1093/bja/aep089
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.