Estimates of the net excitatory currents evoked by visual stimulation of identified neurons in cat visual cortex
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The action potential discharge response of single neurons to both visual stimulation and injections of current were obtained during intracellular recordings in cat visual cortex in order to estimate the net excitatory current arriving at the soma during visual stimulation. Of 45 neurons recorded intracellularly, 19 pyramidal neurons and one basket cell were labelled with horseradish peroxidase. The discharge of all neurons adapted to constant current. For 40 neurons, a single exponential provided a good fit to the adapting discharge (r2 = 0.73 +/- 0.03) for all current intensities. Superficial layer neurons were significantly faster adapting [P < 0.001, mean (+/- SEM) time constant of adaptation = 11.5 +/- 1.3 ms; n = 20] than deep layer neurons (mean time constant of adaptation = 51.4 +/- 6.4 ms; n = 10). The percentage adaptation of the spike frequency, %(peak - adapted rate)/peak, was determined from the fitted exponential. Superficial layer neurons adapted significantly more strongly (P < 0.01, mean = 67 +/- 3%) than deep layer neurons (mean = 51 +/- 5%). The mean firing frequency in response to a current step of 320 ms duration had a linear relationship to the amplitude of the injected current (slope 66 spikes/s/nA; origin zero, mean r2 = 0.94; n = 33). This relationship provided a means of estimating the net peak excitatory current generated by visual stimuli. The estimated mean peak somatic current during the passage of a bar across the receptive field was 1.1 nA and the average current for the duration of the visually evoked discharge was 0.64 nA (n = 17). The transfer response of real and model neurons was obtained by differentiating the discharge response to a step input current and was then used to predict the output of the neuron following an arbitrary input. When these transfer responses were convolved with known input signals in model neurons, the predicted output was close to the simulated response of the model neuron to the same input waveforms. The transfer response was calculated for eight real neurons. Estimates of the net excitatory current arriving at the soma during visual stimulation was obtained by deconvolution. The mean peak somatic current for these neurons was 0.62 nA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McCormick, D. A. (1992) · Progress in Neurobiology · doi:10.1016/0301-0082(92)90012-4 · Cited by 1,117
A functional microcircuit for cat visual cortex
Douglas, R. J., & Martin, K. A. (1991) · The Journal of Physiology · doi:10.1113/jphysiol.1991.sp018733 · Cited by 736 · cited 11×
“Unlike neurons recorded in vitro, which have threshold currents of ∼0.4 nA (Connors et al., 1982; Mason and Larkman, 1990), the striate neurons in vivo are poised close to their threshold (Berman et al., 1991; Douglas et al., 1991).”
BackgroundMethodResultInfluentialSelf-citationA canonical microcircuit for neocortex
Douglas, R. J., Martin, K. A. C., & Whitteridge, D. (1989) · Neural Computation · doi:10.1162/neco.1989.1.4.480 · Cited by 514
Self-citationShunting Inhibition Does Not Have a Divisive Effect on Firing Rates
Holt, G. R., & Koch, C. (1997) · Neural Computation · doi:10.1162/neco.1997.9.5.1001 · Cited by 250
Shepherd, G. M., Brayton, R. K., Miller, J. P., Segev, I., Rinzel, J., & Rall, W. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.7.2192 · Cited by 220
Physiological properties of inhibitory interneurons in cat striate cortex
Azouz, R. (1997) · Cerebral Cortex · doi:10.1093/cercor/7.6.534 · Cited by 173 · cited 2×
“None of the three identified basket cells recorded by Azouz et al. (1997), however, had the bursty discharge patterns seen in this basket cell.”
BackgroundSpatial and temporal contrast sensitivity of striate cortical neurones
TOLHURST, D. J., & MOVSHON, J. A. (1975) · Nature · doi:10.1038/257674a0 · Cited by 167
Relationship between repetitive firing and afterhyperpolarizations in human neocortical neurons
Lorenzon, N. M., & Foehring, R. C. (1992) · Journal of Neurophysiology · doi:10.1152/jn.1992.67.2.350 · Cited by 145 · cited 2×
“Although we found that the fits with two exponentials made little improvement on fits with one exponential, the time constants Lorenzon and Foehring (1992) extracted (range 10–21 ms for the first time constant, 70–159 ms for the second) are broadly consistent with our findings.”
BackgroundResultBaranyi, A., Szente, M. B., & Woody, C. D. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.69.6.1865 · Cited by 84 · cited 2×
“Qualitatively similar findings have been reported in the cat for neurons in motor cortex (Calvin and Sypert, 1976; Baranyi et al., 1993) and association cortical areas 5 and 7 (Nunez et al., 1993).”
BackgroundResult
Cited by
Modulation of Oscillatory Neuronal Synchronization by Selective Visual Attention
Fries, P., Reynolds, J. H., Rorie, A. E., & Desimone, R. (2001) · Science · doi:10.1126/science.1055465 · Cited by 2,786
The time course of perceptual choice: The leaky, competing accumulator model.
Usher, M., & McClelland, J. L. (2001) · Psychological Review · doi:10.1037/0033-295x.108.3.550 · Cited by 2,152
“However, response functions in cortical and motor neurons typically approximate a threshold-linear input-output relation in the range of firing rates observed physiologically (Jagadeesh, Gray & Frester, 1992; see also Ahmed et al, 1995, 1998; Granit, Kernell & Shortess, 1963; Mason & Larkman, 1990).”
BackgroundNeurophysiological and Computational Principles of Cortical Rhythms in Cognition
Wang, X.-J. (2010) · Physiological Reviews · doi:10.1152/physrev.00035.2008 · Cited by 1,939
A Quantitative Map of the Circuit of Cat Primary Visual Cortex
Binzegger, T., Douglas, R. J., & Martin, K. A. C. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.1400-04.2004 · Cited by 878
Self-citationLinking Spontaneous Activity of Single Cortical Neurons and the Underlying Functional Architecture
Tsodyks, M., Kenet, T., Grinvald, A., & Arieli, A. (1999) · Science · doi:10.1126/science.286.5446.1943 · Cited by 715
Metadata
- Authors
- Ahmed, B., Anderson, J. C., Douglas, R. J., Martin, K. A., & Whitteridge, D.
- Venue
- Cerebral Cortex
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-07-01
- Volume
- 8
- Issue
- 5
- Pages
- 462-476
- ISSN
- 1047-3211 (ISSN-L)
- 1460-2199
- OpenAlex
- W2132262604
- Cited by
- 101
- References
- 9
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimates of the net excitatory currents evoked by visual stimulation of identified neurons in cat visual cortex. https://app.cochat.ai/papers/10.1093/cercor/8.5.462
- The paper
- Ahmed, B., Anderson, J. C., Douglas, R. J., Martin, K. A., & Whitteridge, D. (1998). Estimates of the net excitatory currents evoked by visual stimulation of identified neurons in cat visual cortex. Cerebral Cortex. https://doi.org/10.1093/cercor/8.5.462
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.