CoChat

A New Procedure for the Specific High-Performance Liquid Chromatographic Determination of Hydroxyproline

Biondi, P. A., Chiesa, L. M., Storelli, M. R., Renon, P. · 1997 · Journal of Chromatographic Science
Cited by 36

The DOI matches its Crossref record.

Abstract

A procedure suitable for a selective high-performance liquid chromatographic (HPLC) analysis of the imino acid hydroxyproline in the presence of a large excess of amino acids is proposed. To deaminate the amino acids, the well-known reaction with nitrous acid is exploited. The N-nitroso derivatives of imino acids obtained are extracted in ethyl acetate, denitrosated by hydrobromic acid, and treated with dabsyl-chloride. The final HPLC separations are carried out on a reversed-phase column in a rapid isocratic run. The use of the cis isomer of hydroxyproline as an internal standard allows good reproducibility. As an application of the described method, the hydroxyproline content in samples containing collagen and an excess of bovine serum albumine (up to 20:1) is determined.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/chromsci/35.11.509

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 36

Metadata

Authors
Biondi, P. A., Chiesa, L. M., Storelli, M. R., & Renon, P.
Venue
Journal of Chromatographic Science
Published
1997-11-01
Volume
35
Issue
11
Pages
509-512
ISSN
  • 0021-9665 (ISSN-L)
  • 1945-239X
OpenAlex
W2152587418
Cited by
36
References
0
FWCI
0.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A New Procedure for the Specific High-Performance Liquid Chromatographic Determination of Hydroxyproline. https://app.cochat.ai/papers/10.1093/chromsci/35.11.509
The paper
Biondi, P. A., Chiesa, L. M., Storelli, M. R., & Renon, P. (1997). A New Procedure for the Specific High-Performance Liquid Chromatographic Determination of Hydroxyproline. Journal of Chromatographic Science. https://doi.org/10.1093/chromsci/35.11.509

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.