The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Detection of Infectious Influenza Virus in Cough Aerosols Generated in a Simulated Patient Examination Room
Open accessAbstract
BACKGROUND: The potential for aerosol transmission of infectious influenza virus (ie, in healthcare facilities) is controversial. We constructed a simulated patient examination room that contained coughing and breathing manikins to determine whether coughed influenza was infectious and assessed the effectiveness of an N95 respirator and surgical mask in blocking transmission. METHODS: National Institute for Occupational Safety and Health aerosol samplers collected size-fractionated aerosols for 60 minutes at the mouth of the breathing manikin, beside the mouth, and at 3 other locations in the room. Total recovered virus was quantitated by quantitative polymerase chain reaction and infectivity was determined by the viral plaque assay and an enhanced infectivity assay. RESULTS: Infectious influenza was recovered in all aerosol fractions (5.0% in >4 μm aerodynamic diameter, 75.5% in 1-4 μm, and 19.5% in <1 μm; n = 5). Tightly sealing a mask to the face blocked entry of 94.5% of total virus and 94.8% of infectious virus (n = 3). A tightly sealed respirator blocked 99.8% of total virus and 99.6% of infectious virus (n = 3). A poorly fitted respirator blocked 64.5% of total virus and 66.5% of infectious virus (n = 3). A mask documented to be loosely fitting by a PortaCount fit tester, to simulate how masks are worn by healthcare workers, blocked entry of 68.5% of total virus and 56.6% of infectious virus (n = 2). CONCLUSIONS: These results support a role for aerosol transmission and represent the first reported laboratory study of the efficacy of masks and respirators in blocking inhalation of influenza in aerosols. The results indicate that a poorly fitted respirator performs no better than a loosely fitting mask.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Influenza Virus in Human Exhaled Breath: An Observational Study
Fabian, P., McDevitt, J. J., DeHaan, W. H., Fung, R. O. P., Cowling, B. J., Chan, K. H., Leung, G. M., & Milton, D. K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002691 · Cited by 496
Loeb, M., Dafoe, N., Mahony, J., John, M., Sarabia, A., Glavin, V., Webby, R., Smieja, M., Earn, D. J. D., Chong, S., et al. (2009) · JAMA · doi:10.1001/jama.2009.1466 · Cited by 465
Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs
Lindsley, W. G., Blachere, F. M., Thewlis, R. E., Vishnu, A., Davis, K. A., Cao, G., Palmer, J. E., Clark, K. E., Fisher, M. A., Khakoo, R., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015100 · Cited by 423
Self-citationSurgical mask filter and fit performance
Oberg, T., & Brosseau, L. M. (2008) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.07.008 · Cited by 310
Schaffer, F. L., Soergel, M. E., & Straube, D. C. (1976) · Archives of Virology · doi:10.1007/bf01317930 · Cited by 302
Lee, S.-A., Grinshpun, S. A., & Reponen, T. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men005 · Cited by 235
Exhalation of respiratory viruses by breathing, coughing, and talking
Stelzer‐Braid, S., Oliver, B. G., Blazey, A. J., Argent, E., Newsome, T. P., Rawlinson, W. D., & Tovey, E. R. (2009) · Journal of Medical Virology · doi:10.1002/jmv.21556 · Cited by 165
A two-stage cyclone using microcentrifuge tubes for personal bioaerosol sampling.
Lindsley, W. G., Schmechel, D., & Chen, B. T. (2006) · Journal of Environmental Monitoring · doi:10.1039/b609083d · Cited by 117
Self-citationFiltration Performance of FDA-Cleared Surgical Masks
Rengasamy*, S., Miller, A., Eimer, B. C., & Shaffer, R. E. (2009) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.167200 · Cited by 69
Cited by
Radonovich, L. J., Simberkoff, M. S., Bessesen, M. T., Brown, A. C., Cummings, D. A. T., Gaydos, C. A., Los, J. G., Krosche, A. E., Gibert, C. L., Gorse, G. J., et al. (2019) · JAMA · doi:10.1001/jama.2019.11645 · Cited by 447
Long, Y., Hu, T., Liu, L., Chen, R., Guo, Q., Yang, L., Cheng, Y., Huang, J., & Du, L. (2020) · Journal of Evidence-Based Medicine · doi:10.1111/jebm.12381 · Cited by 339
Aerosol transmission is an important mode of influenza A virus spread
Cowling, B. J., Ip, D. K. M., Fang, V. J., Suntarattiwong, P., Olsen, S. J., Levy, J., Uyeki, T. M., Leung, G. M., Malik Peiris, J. S., Chotpitayasunondh, T., et al. (2013) · Nature Communications · doi:10.1038/ncomms2922 · Cited by 346
Smith, J. D., MacDougall, C. C., Johnstone, J., Copes, R. A., Schwartz, B., & Garber, G. E. (2016) · Canadian Medical Association Journal · doi:10.1503/cmaj.150835 · Cited by 328
Collection, particle sizing and detection of airborne viruses
Pan, M., Lednicky, J. A., & Wu, C. ‐. (2019) · Journal of Applied Microbiology · doi:10.1111/jam.14278 · Cited by 261
Metadata
- Authors
- Noti, J. D., Lindsley, W. G., Blachere, F. M., Cao, G., Kashon, M. L., Thewlis, R. E., McMillen, C. M., King, W. P., Szalajda, J. V., & Beezhold, D. H.
- Venue
- Clinical Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-03-29
- Volume
- 54
- Issue
- 11
- Pages
- 1569-1577
- ISSN
- 1058-4838 (ISSN-L)
- 1537-6591
- OpenAlex
- W2133842815
- Cited by
- 170
- References
- 9
- FWCI
- 8.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Infectious Influenza Virus in Cough Aerosols Generated in a Simulated Patient Examination Room. https://app.cochat.ai/papers/10.1093/cid/cis237
- The paper
- Noti, J. D., Lindsley, W. G., Blachere, F. M., Cao, G., Kashon, M. L., Thewlis, R. E., McMillen, C. M., King, W. P., Szalajda, J. V., & Beezhold, D. H. (2012). Detection of Infectious Influenza Virus in Cough Aerosols Generated in a Simulated Patient Examination Room. Clinical Infectious Diseases. https://doi.org/10.1093/cid/cis237
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.