The TYCHO system for computer analysis of two-dimensional gel electrophoresis patterns.
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
We describe here a computer system for the analysis of high-resolution two-dimensional gel-electrophoresis patterns, with some initial applications. The system (called TYCHO) comprises programs for image acquisition, background subtraction and smoothing, spot detection, gaussian spot modeling, and pattern matching and comparison. It is based on a conventional minicomputer, but makes extensive use of a high-speed array processor in the image-processing and -modeling steps. Used in concert with the ISO-DALT two-dimensional electrophoresis system (Anal. Biochem. 85:331-354, 1978), TYCHO allows quantitative measurement of hundreds of proteins in complex biological samples, and constitutes the initial data-reduction system required for work towards a Human Protein Index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4
LAEMMLI, U. K. (1970) · Nature · doi:10.1038/227680a0 · Cited by 249,961 · cited 1×
“…involve isoelectric focusing (IEF; 7) in urea and non-ionic detergents in the first dimension, and sodium dodecyl sulfate (SDS) electrophoresis (8, 9) in the second, yielding a two-dimensional map in which proteins are separated on the basis of chemical properties (p1) in one direction and on the…”
BackgroundWeber, K., & Osborn, M. (1969) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)94333-4 · Cited by 20,298 · cited 1×
“…involve isoelectric focusing (IEF; 7) in urea and non-ionic detergents in the first dimension, and sodium dodecyl sulfate (SDS) electrophoresis (8, 9) in the second, yielding a two-dimensional map in which proteins are separated on the basis of chemical properties (p1) in one direction and on…”
BackgroundHigh resolution two-dimensional electrophoresis of proteins.
O'Farrell, P. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41496-8 · Cited by 19,246 · cited 2×
“Combining in series two quite different such methods, each having high individual resolving power (>100 proteins), O’Farrell (3) and others (4-6) developed two-dimensional gel electrophoretic techniques that could resolve about 10000 proteins.”
BackgroundMethodVesterberg, O., Svensson, H., Nevald, R., Frank, V., Brunvoll, J., Bunnenberg, E., Djerassi, C., & Records, R. (1966) · Acta Chemica Scandinavica · doi:10.3891/acta.chem.scand.20-0820 · Cited by 1,301 · cited 1×
“Autoradlograph of a separation of human peripheral blood leukocyte proteins labeled with 35S-methionine Several Identified proteins are labeled including actln, tubulin (7), lymphocyte intermediate filament protein (IF!’), 2 microglobulin (2-A, calmodulln, enolase, lymphocyte fropomosins (Tm), the LDH-B chain, and put…”
BackgroundKlose, J. (1975) · Humangenetik · doi:10.1007/bf00281458 · Cited by 1,207
Garrels, J. I. (1979) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)36039-3 · Cited by 738 · cited 3×
“Ideally, densitometry of spots on two-dimensional gels with very low sample loads would yield two-dimensional gaussian peaks (22, 33) having slightly different half-widths in the two dimensions.”
BackgroundMethodHigh resolution two-dimensional electrophoresis of human plasma proteins.
Anderson, L., & Anderson, N. G. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.12.5421 · Cited by 648 · cited 1×
“…technology, and its development into a re-producible, calibrated, routine analytical tool (10-13), now allow us to separate and make visible thousands of cellular and body fluid proteins (14-20) and thereby become familiar with a greatly increased proportion of the working parts of human cells.”
BackgroundSelf-citationAnalytical techniques for cell fractions
Pearson, T., & Anderson, L. (1980) · Analytical Biochemistry · doi:10.1016/0003-2697(80)90203-1 · Cited by 622
Acrylamide Gel as a Supporting Medium for Zone Electrophoresis
RAYMOND, S., & WEINTRAUB, L. (1959) · Science · doi:10.1126/science.130.3377.711 · Cited by 492 · cited 1×
“The introduction of electrophoretic separations in acrylamide gels (1,2) substantially improved the possible resolution.”
BackgroundScheele, G. A. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41192-7 · Cited by 391 · cited 1×
“Combining in series two quite different such methods, each having high individual resolving power (>100 proteins), O’Farrell (3) and others (4-6) developed two-dimensional gel electrophoretic techniques that could resolve about 10000 proteins.”
Background
Cited by
Proteome and proteomics: New technologies, new concepts, and new words
Anderson, N. L., & Anderson, N. G. (1998) · ELECTROPHORESIS · doi:10.1002/elps.1150191103 · Cited by 1,055
Self-citationKlose, J., & Kobalz, U. (1995) · ELECTROPHORESIS · doi:10.1002/elps.11501601175 · Cited by 714
Protein identification in the post-genome era: the rapid rise of proteomics
JAMES, P. (1997) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583597003399 · Cited by 285
Two-dimensional gel electrophoresis in proteomics: A tutorial
Rabilloud, T., & Lelong, C. (2011) · Journal of Proteomics · doi:10.1016/j.jprot.2011.05.040 · Cited by 258
The state of the art in the analysis of two-dimensional gel electrophoresis images
Berth, M., Moser, F. M., Kolbe, M., & Bernhardt, J. (2007) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-007-1128-0 · Cited by 254
Two-dimensional gel electrophoresis of proteins
Dunn, M. J. (1987) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/0378-4347(87)80008-7 · Cited by 202
The role of bioinformatics in two‐dimensional gel electrophoresis
Dowsey, A. W., Dunn, M. J., & Yang, G. (2003) · PROTEOMICS · doi:10.1002/pmic.200300459 · Cited by 186
Thompson, D. K., Beliaev, A. S., Giometti, C. S., Tollaksen, S. L., Khare, T., Lies, D. P., Nealson, K. H., Lim, H., Yates, J., Brandt, C. C., et al. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.2.881-892.2002 · Cited by 171
“The images were then processed, and parameter lists (spot files) were generated using the Tycho II software developed at Argonne National Laboratory ( 4 ).”
MethodTwo-dimensional electrophoresis in proteome expression analysis
López, J. L. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.11.049 · Cited by 171
Gas chromatographic methods for oil analysis
Blomberg, J., Schoenmakers, P. J., & Brinkman, U. A. T. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00995-0 · Cited by 160
Secondary proteolysis of cheese during ripening: A review
Rank, T. C., Grappin, R., & Olson, N. F. (1985) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(85)80895-x · Cited by 129
“With complex solutions, the variety of or number of peptides/protein s separated may be best analyzed by use of a computer ( 2 ).”
Background
Metadata
- Authors
- Anderson, N. L., Taylor, J., Scandora, A. E., Coulter, B. P., & Anderson, N. G.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1981-11-01
- Volume
- 27
- Issue
- 11
- Pages
- 1807-1820
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2030462329
- Cited by
- 207
- References
- 14
- FWCI
- 8.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.