CoChat

Measurement of hemoglobin A1c by a new liquid-chromatographic assay: methodology, clinical utility, and relation to glucose tolerance evaluated.

Jeppsson, J O, Jerntorp, P, Sundkvist, G, Englund, H, Nylund, V · 1986 · Clinical Chemistry
Cited by 299

The DOI matches its Crossref record.

Abstract

A chromatographic method for determining glycated hemoglobin (Hb A1c) by use of a new monodisperse cation-exchanger has been investigated. Hb A1c was separated from other "minor hemoglobins": Hb F, Hb A3 (the glutathione adduct), and the acetaldehyde adduct in alcoholics. The method was fully automated and a single column could be used for more than 1000 runs. The normal reference interval was 4.0-5.2%; the interval for diabetic outpatients was 5.6-12.4%. Within-run and the between-run CVs were less than 0.9% and 1.7%, respectively. Carbamylation in uremic patients who were undergoing hemodialysis increased the proportion of Hb A1c to 1%. Hb A1c results were compared with results from glucose tolerance tests. In our study, Hb A1c less than 5.5% excluded diabetes: subjects with Hb A1c greater than 6.2% showed diabetes. If blood sampled during fasting had been screened with determinations of glucose and Hb A1c, only 20% of referred subjects would have needed an oral glucose tolerance test for diagnosis of diabetes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/32.10.1867

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Jeppsson, J. O., Jerntorp, P., Sundkvist, G., Englund, H., & Nylund, V
Venue
Clinical Chemistry
Published
1986-10-01
Volume
32
Issue
10
Pages
1867-1872
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W4299493480
Cited by
299
References
0
FWCI
6.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.