Accuracy and precision of breath-alcohol measurements for a random subject in the postabsorptive state.

Simpson, G·1987·Clinical Chemistry

Abstract

The accuracy of estimates of blood-alcohol concentration based on measurements of breath-alcohol concentration in a randomly selected subject by a random quantitative evidential breath-alcohol analyzer is evaluated with respect to the breath analyzer itself, its calibration, and the biological variables of the subject being tested. There are no suitable experimental data for rigorous determination of the overall accuracy, so I estimate it from the CV of the available data. I find that the uncertainty in these breath-analyzer readings for a random subject in the postabsorptive state is at least +/- 15%, +/- 19%, or +/- 27%, depending on whether +/- 2 CV, the experimental range, or +/- 3 CV, respectively, is used to express the overall uncertainty. Over 90% of this uncertainty is due to biological variables of the subject, and at least 23% of subjects will have their actual blood-alcohol concentration overestimated. Manufacturers' specifications for the accuracy and precision of these instruments are inconsistent with the experimental values reported in the literature and I recommend that an appropriate amount of uncertainty be reflected in the results from these breath analyzers, especially when they are used for law-enforcement purposes.

Integrity signals

Registry

Crossref · 10.1093/clinchem/33.2.261

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • BrAC instruments calculate BAC by following Henry's law, but may compromise accuracy because results can be easily affected by humidity, temperature, and individual traits.

    “BrAC instruments calculate BAC by following Henry's law, but may compromise accuracy since the results can be easily affected by humidity, temperature, and individual traits.7,8”

Cited by

Sorted by citations

Authors
Simpson, G.
Corresponding author
Simpson, G
Venue
Clinical Chemistry
Published
1987-02-01
Volume
33
Issue
2
Pages
261-268
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2171522650
Cited by
25
References
0
Citations by year
2025: 1 · 2019: 1 · 2018: 2 · 2017: 1 · 2016: 3 · 2015: 1 · 2013: 1
FWCI
2.42
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
Keywords
breath alcohol concentration, blood alcohol concentration, measurement precision, measurement uncertainty, coefficient of variation, postabsorptive state, calibration, biological variation, law enforcement, alcohol testing
MeSH terms
Absorption, Ethanol, Breath Tests, False Positive Reactions, Forensic Medicine, Humans, Quality Control, Statistics as Topic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review