Free and bound malondialdehyde measured as thiobarbituric acid adduct by HPLC in serum and plasma
The DOI matches its Crossref record.
Abstract
Assay of free and total malondialdehyde (MDA) in human serum and plasma from healthy subjects and from patients with high risk of lipoperoxidation was performed as follows: (a) acidic (HClO4, pH 1, at 20 degrees C) or basic (NaOH, pH 13, at 60 degrees C) treatments for 30 min; (b) reaction of the protein-free extract (obtained by acid precipitation) with thiobarbituric acid (TBA); (c) HPLC separation on C18 columns with an eluting solution of methanol/phosphate buffer, 10 mmol/L, pH 5.8 (40/60, by vol), at a flow rate of 1.5 mL/min. Free MDA averaged 0.042 (SEM 0.008) and 0.043 (SEM 0.007) mumol/L, respectively, in serum and plasma from healthy subjects. Free (+/- SEM) MDA increased significantly in the plasma from cancer patients (0.270 +/- 0.047 mumol/L) and from hemodialyzed patients (0.214 +/- 0.035 mumol/L). In serum of hemodialyzed patients, analyses for total MDA were unsuitable because of interfering peaks. MDA bound to NH2 groups constituted 83.2% and 83.5% of total MDA in serum and plasma of healthy subjects, respectively, and only 58% in plasma of hemodialyzed patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tsikas, D. (2017) · Analytical Biochemistry · doi:10.1016/j.ab.2016.10.021 · Cited by 2,190
“PlasmaMDAwasmeasured by HPLC with absorbance detection at 532 nm after appropriate method validation.”
BackgroundMethodInfluentialNielsen, F., Mikkelsen, B. B., Nielsen, J. B., Andersen, H. R., & Grandjean, P. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.7.1209 · Cited by 1,016
Antioxidant assays for plant and food components
Moon, J.-K., & Shibamoto, T. (2009) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf803537k · Cited by 958
Wasowicz, W., Nève, J., & Peretz, A. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.12.2522 · Cited by 639
Evidence of increased oxidative damage in subjects with mild cognitive impairment
Keller, J. N., Schmitt, F. A., Scheff, S. W., Ding, Q., Chen, Q., Butterfield, D. A., & Markesbery, W. R. (2005) · Neurology · doi:10.1212/01.wnl.0000156156.13641.ba · Cited by 539
Metadata
- Authors
- Carbonneau, M. A., Peuchant, E., Sess, D., Canioni, P., & Clerc, M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-08-01
- Volume
- 37
- Issue
- 8
- Pages
- 1423-1429
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1951557411
- Cited by
- 145
- References
- 0
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Free and bound malondialdehyde measured as thiobarbituric acid adduct by HPLC in serum and plasma. https://app.cochat.ai/papers/10.1093/clinchem/37.8.1423
- The paper
- Carbonneau, M. A., Peuchant, E., Sess, D., Canioni, P., & Clerc, M. (1991). Free and bound malondialdehyde measured as thiobarbituric acid adduct by HPLC in serum and plasma. Clinical Chemistry. https://doi.org/10.1093/clinchem/37.8.1423
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.