Interlaboratory Standardization of Measurements of Glycohemoglobins
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The diversity of methods used to measure glycohemoglobins (GHb) makes it difficult to compare patients' results among laboratories. We reported previously the feasibility of providing comparable results from different assays by use of common calibrators. We here compare results from seven different GHb methods calibrated by use of hemolysates assayed by a precise ion-exchange high-performance liquid-chromatographic (HPLC) method for hemoglobin A1c (HbA1c). Thus, regardless of the GHb species measured by the seven methods, results were referenced to the HbA1c content of the calibrators. Without this calibration, GHb values for single samples varied, e.g., from 4.0% to 8.1% and from 10% to 14.2% in the normal and high ranges, respectively. Calibration decreased between-method variability (single sample ranges of, e.g., 4.8% to 5.4% and 9.4% to 10.2% in the normal and high ranges, respectively) and improved interassay precision. We conclude that this approach to calibration of GHb measurements allows direct comparison of results obtained by different methods and improves precision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wiechelman, K. J., Braun, R. D., & Fitzpatrick, J. D. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90383-1 · Cited by 766
Nonenzymatic glycosylation of protein: relevance to diabetes
Bunn, H. F. (1981) · The American Journal of Medicine · doi:10.1016/0002-9343(81)90769-5 · Cited by 171 · cited 1×
“Studies indicate that, under most circumstances, GHb is a reliable measure of average blood glucose concentration during the preceding 2 to 3 months (1-5).”
BackgroundEffects of acute changes in blood glucose on HbA1c
Goldstein, D. E., Peth, S. B., England, J. D., Hess, R. L., & Costa, J. D. (1980) · Diabetes · doi:10.2337/diab.29.8.623 · Cited by 145
Self-citation
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Sacks, D. B., Bruns, D. E., Goldstein, D. E., Maclaren, N. K., McDonald, J. M., & Parrott, M. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.3.436 · Cited by 1,130
Self-citationAmerican Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.2007.s106 · Cited by 988
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
Cowie, C. C., Rust, K. F., Byrd-Holt, D. D., Gregg, E. W., Ford, E. S., Geiss, L. S., Bainbridge, K. E., & Fradkin, J. E. (2010) · Diabetes Care · doi:10.2337/dc09-1524 · Cited by 689
Goldstein, D. E., Little, R. R., Lorenz, R. A., Malone, J. I., Nathan, D., Peterson, C. M., & Sacks, D. B. (2004) · Diabetes Care · doi:10.2337/diacare.27.7.1761 · Cited by 625
Self-citationKrolewski, A. S., Laffel, L. M. B., Krolewski, M., Quinn, M., & Warram, J. H. (1995) · New England Journal of Medicine · doi:10.1056/nejm199505113321902 · Cited by 452
Mahmoud, A. M., Ashour, M. B., Abdel-Moneim, A., & Ahmed, O. M. (2012) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2012.06.001 · Cited by 374
(2001) · PubMed · Cited by 344
Review of hemoglobin A1c in the management of diabetes
GALLAGHER, E. J., LE ROITH, D., & BLOOMGARDEN, Z. (2009) · Journal of Diabetes · doi:10.1111/j.1753-0407.2009.00009.x · Cited by 304
FRANZ, M. J., MONK, A., BARRY, B., McCLAIN, K., WEAVER, T., COOPER, N., UPHAM, P., BERGENSTAL, R., & MAZZE, R. S. (1995) · Journal of the American Dietetic Association · doi:10.1016/s0002-8223(95)00276-6 · Cited by 289
Candidate reference methods for hemoglobin A1c based on peptide mapping
Kobold, U., Jeppsson, J.-O., Dülffer, T., Finke, A., Hoelzel, W., & Miedema, K. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.10.1944 · Cited by 181
“As a result, values differ in a clinically unacceptable magnitude between methods and laboratories as has been demonstrated in several trials [8–12].”
ResultThe long and winding road to optimal HbA1c measurement
Little, R. R., & Rohlfing, C. L. (2013) · Clinica Chimica Acta · doi:10.1016/j.cca.2012.12.026 · Cited by 170
“Later studies showed, however, that such an approach, although simple, did not work for a number of existing methods [28].”
ResultSelf-citationSkeie, S., Thue, G., Nerhus, K., & Sandberg, S. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.7.994 · Cited by 131
“HbA1c was analyzed on a Diamat HPLC (Bio-Rad Laboratories) calibrated to give values similar to the Diabetes Control and Complications Trial method ( 28 ). Total analysis time on the portable instruments was 5 min.”
MethodRisk Factors for Hearing Impairment Among U.S. Adults With Diabetes
Bainbridge, K. E., Hoffman, H. J., & Cowie, C. C. (2011) · Diabetes Care · doi:10.2337/dc10-2161 · Cited by 99
Cefalu, W. T., Wang, Z. Q., Bell-Farrow, A., Kiger, F. D., & Izlar, C. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.7.1317 · Cited by 92
Berg, A. H., & Sacks, D. B. (2008) · Journal of Clinical Pathology · doi:10.1136/jcp.2007.049205 · Cited by 41
Prevalence and characteristics of diabetic patients in a chronic heart failure population
Kistorp, C., Galatius, S., Gustafsson, F., Faber, J., Corell, P., & Hildebrandt, P. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.10.024 · Cited by 33
“HbA1c was measured using an immuno-turbidimetric assay, which is well correlated with the high performance liquid chromatography assay, and recommended as traceable to the DCCT reference method [37].”
Method
Metadata
- Authors
- Little, R. R., Wiedmeyer, H. M., England, J. D., Wilke, A. L., Rohlfing, C. L., Wians, F. H., Jacobson, J. M., Zellmer, V, & Goldstein, D. E.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-12-01
- Volume
- 38
- Issue
- 12
- Pages
- 2472-2478
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2148104420
- Cited by
- 113
- References
- 3
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.