Rare earth cryptates and homogeneous fluoroimmunoassays with human sera
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The rare earth cryptates are used as long-lived fluorescent labels. They are formed by inclusion of a europium ion in the intramolecular cavity of a macropolycyclic ligand containing bipyridine groups as light absorbers. The use of fluoride ions in the measuring medium allows a total shielding of the label fluorescence. Here, I have established the conditions under which the signal of these cryptates can be amplified through the use of nonradiative energy transfer, and applied these conditions to homogeneous immunoassays by using allophycocyanin as the acceptor. Because only a low proportion of the cryptate label is involved in the transfer amplification, and because allophycocyanin emission occurs between the europium emission lines, time-resolved measurement of europium and allophycocyanin emission allows real-time correction of the optical properties of the assay medium. These features have allowed the development of a rapid homogeneous immunoassay of prolactin that can detect as little as 0.3 microgram/L (3rd International Standard 84/500).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zwischenmolekulare Energiewanderung und Fluoreszenz
Förster, T. (1948) · Annalen der Physik · doi:10.1002/andp.19484370105 · Cited by 8,285
Fluorescence Energy Transfer as a Spectroscopic Ruler
Stryer, L. (1978) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.47.070178.004131 · Cited by 2,406
Luminescent lanthanide complexes as photochemical supramolecular devices
Sabbatini, N., Guardigli, M., & Lehn, J.-M. (1993) · Coordination Chemistry Reviews · doi:10.1016/0010-8545(93)85056-a · Cited by 1,674
Cryptates: the chemistry of macropolycyclic inclusion complexes
Lehn, J. M. (1978) · Accounts of Chemical Research · doi:10.1021/ar50122a001 · Cited by 826
Fluorescent phycobiliprotein conjugates for analyses of cells and molecules.
Oi, V. T., Glazer, A. N., & Stryer, L. (1982) · The Journal of cell biology · doi:10.1083/jcb.93.3.981 · Cited by 454
Fluoroimmunoassay: present status and key problems.
Soini, E., & Hemmilä, I. (1979) · Clinical Chemistry · doi:10.1093/clinchem/25.3.353 · Cited by 429
Fluoroimmunoassays and immunofluorometric assays.
Hemmilä, I. (1985) · Clinical Chemistry · doi:10.1093/clinchem/31.3.359 · Cited by 303
ANTENNA EFFECT IN LUMINESCENT LANTHANIDE CRYPTATES: A PHOTOPHYSICAL STUDY
Alpha, B., Ballardini, R., Balzani, V., Lehn, J., Perathoner, S., & Sabbatini, N. (1990) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1990.tb04185.x · Cited by 278
Fluorescence energy transfer in the rapid-diffusion limit
Thomas, D. D., Carlsen, W. F., & Stryer, L. (1978) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.75.12.5746 · Cited by 168
Europium(III) cryptate: A fluorescent label for the detection of DNA hybrids on solid support
Prat, O., Lopez, E., & Mathis, G. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90331-m · Cited by 89
Self-citation
Cited by
Principles and Biophysical Applications of Lanthanide-Based Probes
Selvin, P. R. (2002) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.31.101101.140927 · Cited by 549
[13] Fluorescence resonance energy transfer
Selvin, P. R. (1995) · Methods in Enzymology · doi:10.1016/0076-6879(95)46015-2 · Cited by 517
Degorce, F. (2009) · Current Chemical Genomics · doi:10.2174/1875397300903010022 · Cited by 501
“The first acceptor developed for HTRF was XL665, a phycobiliprotein pigment purified from red algae [6].”
BackgroundProgress in Lanthanides as Luminescent Probes
Hemmilä, I., & Laitala, V. (2005) · Journal of Fluorescence · doi:10.1007/s10895-005-2826-6 · Cited by 458
Binnemans, K. (2005) · Handbook on the Physics and Chemistry of Rare Earths · doi:10.1016/s0168-1273(05)35003-3 · Cited by 457
Mathis, G. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.9.1391 · Cited by 339
“Moreover, the fluorescence of the free acceptor being short lived, its contribution to the specific signal is negligible (20).”
Self-citationLuminescence energy transfer using a terbium chelate: improvements on fluorescence energy transfer.
Selvin, P. R., & Hearst, J. E. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.21.10024 · Cited by 299
Quantum Dot Biosensors for Ultrasensitive Multiplexed Diagnostics
Geißler, D., Charbonnière, L. J., Ziessel, R. F., Butlin, N. G., Löhmannsröben, H., & Hildebrandt, N. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906399 · Cited by 283
Recent advances in utilization of transition metal complexes and lanthanides as diagnostic tools
Yam, V. W.-W., & Lo, K. K.-W. (1999) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(98)00262-8 · Cited by 268
Fluorescence in Nanobiotechnology: Sophisticated Fluorophores for Novel Applications
Hötzer, B., Medintz, I. L., & Hildebrandt, N. (2012) · Small · doi:10.1002/smll.201200109 · Cited by 220
Szöllosi, J., Damjanovich, S., & Mátyus, L. (1998) · Cytometry · doi:10.1002/(sici)1097-0320(19980815)34:4<159::aid-cyto1>3.3.co;2-9 · Cited by 214
Mayilo, S., Kloster, M. A., Wunderlich, M., Lutich, A., Klar, T. A., Nichtl, A., Kürzinger, K., Stefani, F. D., & Feldmann, J. (2009) · Nano Letters · doi:10.1021/nl903178n · Cited by 213
Hildebrandt, N., Wegner, K. D., & Algar, W. R. (2014) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2014.01.020 · Cited by 198
Six-Color Time-Resolved Förster Resonance Energy Transfer for Ultrasensitive Multiplexed Biosensing
Geißler, D., Stufler, S., Löhmannsröben, H.-G., & Hildebrandt, N. (2013) · Journal of the American Chemical Society · doi:10.1021/ja310317n · Cited by 191
Time-resolved detection of lanthanide luminescence for ultrasensitive bioanalytical assays
Gudgin Dickson, E. F., Pollak, A., & Diamandis, E. P. (1995) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/1011-1344(94)07086-4 · Cited by 182
Effects of pH and low density lipoprotein (LDL) on PCSK9-dependent LDL receptor regulation
Fisher, T. S., Surdo, P. L., Pandit, S., Mattu, M., Santoro, J. C., Wisniewski, D., Cummings, R. T., Calzetta, A., Cubbon, R. M., Fischer, P. A., et al. (2007) · Journal of Biological Chemistry · doi:10.1074/jbc.m701634200 · Cited by 181
Lanthanide Complex-Based Fluorescence Label for Time-Resolved Fluorescence Bioassay
Yuan, J., & Wang, G. (2005) · Journal of Fluorescence · doi:10.1007/s10895-005-2829-3 · Cited by 173
“G. Mathis (1993).”
Zhou, G. (1998) · Molecular Endocrinology · doi:10.1210/me.12.10.1594 · Cited by 172
New assay technologies for high-throughput screening
Silverman, L., Campbell, R., & Broach, J. R. (1998) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(98)80015-x · Cited by 151
Schäferling, M., & Nagl, S. (2011) · Methods in Molecular Biology · doi:10.1007/978-1-61779-043-0_19 · Cited by 22
Metadata
- Authors
- Mathis, G.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-09-01
- Volume
- 39
- Issue
- 9
- Pages
- 1953-1959
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2155645504
- Cited by
- 392
- References
- 11
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.