CoChat

Evaluation of reproducibility of a vessel wall movement detector system for assessment of large artery properties

Kool, M J F, Merode, T v., Reneman, R S, Hoeks, A P G, Boudier, H A J S., Bortel, L M A B V. · 1994 · Cardiovascular Research
Cited by 145

The DOI matches its Crossref record.

Abstract

OBJECTIVE: Arterial distensibility (DC) and compliance (CC) are vessel wall properties of large arteries that can be measured non-invasively with a custom made vessel wall movement detector system (VWMDS). This study investigated the reproducibility of this device in 10 volunteers. METHODS: To investigate intraobserver intrasession and intraobserver intersession variability, arterial diameter (D) and relative change in diameter during the heart cycle (delta D/D) were measured in the elastic common carotid artery, and in the muscular femoral and brachial arteries. Interobserver intrasession variability was examined in common carotid artery by two observers, while interobserver variability on the same image was assessed for common carotid and femoral arteries. Variability was expressed as the coefficient of variation. RESULTS: For common carotid artery, intraobserver intrasession variability was 7.9(SEM 1.6)% (delta D/D), 4.5(1.1)% (D), 8.3(1.3)% (DC), and 9.1(2.6)% (CC), respectively. In femoral artery it was 12.4(2.2)% (delta D/D), 2.7(0.6)% (DC), 13.4(2.2)% (DC), and 12.5(2.1)% (CC). For brachial artery it was 13.4(2.8)% (delta D/D), 2.5(0.5)% (D), 16.1(2.5)% (DC), and 15.6(2.6)% (CC). Intraobserver intersession variability was comparable to intraobserver intrasession variability for all vessels. Interobserver intrasession variability for common carotid artery was 11.3(2.6)% (delta D/D) and 8.6(1.9)% (D), but was larger for DC and CC. Interobserver variability on the same image was < 5% for common carotid and femoral arteries. CONCLUSIONS: In conclusion, the vessel wall movement detector system has a good technical reproducibility. Intraobserver intrasession and intersession variability are comparable, and are larger in muscular arteries. This might be due to a larger variation in tone of these arteries, which are under permanent neurohumoral control. Interobserver intrasession variability was larger than intraobserver variability and might be influenced by differences in observers' skill and spontaneous variation in vessel wall properties.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/cvr/28.5.610

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Kool, M. J. F., Merode, T. V., Reneman, R. S., Hoeks, A. P. G., Boudier, H. A. J. S., & Bortel, L. M. A. B. V.
Venue
Cardiovascular Research
Published
1994-05-01
Volume
28
Issue
5
Pages
610-614
ISSN
0008-6363 (ISSN-L)
OpenAlex
W2003667937
Cited by
145
References
0
FWCI
4.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.