Wall shear stress and flow patterns in the ascending aorta in patients with bicuspid aortic valves differ significantly from tricuspid aortic valves: a prospective study
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
AIMS: We compared flow and wall shear stress (WSS) patterns in the ascending aorta of individuals with either bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) using four-dimensional cardiovascular magnetic resonance (4D-CMR). BAV are known to be associated with dilation and dissection of the ascending aorta. However, the cause of vessel disease in patients with BAVs is unknown. Inborn connective tissue disease and also dilation secondary to increased WSS because of altered blood flow patterns in the ascending aorta are discussed as causes for dilation of the aorta. WSS can be estimated non-invasively by 4D-CMR. METHODS AND RESULTS: Eighteen, otherwise, healthy individuals with functionally normal BAVs were compared prospectively with an age- and sex-matched control group of healthy individuals with TAV. Blood flow data were obtained by 4D-CMR visualization and WSS was calculated with specific software tools. Eighty-five per cent of the individuals with BAVs showed a high-grade helical flow pattern in the ascending aorta compared with 6% of the individuals with TAV. WSS in the ascending aorta was significantly altered in individuals with BAVs compared with TAV. CONCLUSION: WSS and flow patterns in the ascending aorta in patients with BAVs without concomitant valve or vessel disease are significantly different compared with TAV. The significantly higher shear forces may have an impact on the development of aortic dilation in patients with BAVs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802 · cited 1×
“The mechanical shear forces induced by the blood flow seem to play an important role in the process of vascular remodelling.(17,28) Altered flow characteristics with regionally varying WSS has been demonstrated by Frydrychowicz et al.”
BackgroundKu, D. N., Giddens, D. P., Zarins, C. K., & Glagov, S. (1985) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.5.3.293 · Cited by 2,707
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O'Gara, P. T., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.007 · Cited by 2,257
Siu, S. C., & Silversides, C. K. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.068 · Cited by 1,028
The congenitally bicuspid aortic valve
Roberts, W. C. (1970) · The American Journal of Cardiology · doi:10.1016/0002-9149(70)90761-7 · Cited by 924
Incidence of Aortic Complications in Patients With Bicuspid Aortic Valves
Michelena, H. I., Khanna, A. D., Mahoney, D., Margaryan, E., Topilsky, Y., Suri, R. M., Eidem, B., Edwards, W. D., Sundt, T. M., & Enriquez-Sarano, M. (2011) · JAMA · doi:10.1001/jama.2011.1286 · Cited by 825
Clinical and Pathophysiological Implications of a Bicuspid Aortic Valve
Fedak, P. W. M., Verma, S., David, T. E., Leask, R. L., Weisel, R. D., & Butany, J. (2002) · Circulation · doi:10.1161/01.cir.0000027905.26586.e8 · Cited by 800
Journal of Heart Valve Disease
(2024) · Journal of Heart Valve Disease · doi:10.47310/jhvd · Cited by 525
Stalder, A. F., Russe, M. F., Frydrychowicz, A., Bock, J., Hennig, J., & Markl, M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21778 · Cited by 474 · cited 3×
“Blood flow pattern The generated data sets were further processed by EnSight software package (EnSight; CEI, Apex, NC, USA) as previously described (Figure 1).(18,19,21,22,25,26) Hereby, it was possible to generate 3D interactive anatomical images of the thoracic aorta.”
MethodSelf-citation
Cited by
Michelena, H. I., Prakash, S. K., Della Corte, A., Bissell, M. M., Anavekar, N., Mathieu, P., Bossé, Y., Limongelli, G., Bossone, E., Benson, D. W., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.007851 · Cited by 442
“Eccentric systolic jets resulting in abnormal right-handed helical ascending aorta flow have been identified in BAV patients, even in normally functioning BAVs with normal aortic diameters.(64,90) Furthermore, an increased flow angle (jet eccentricity) was associated with greater aortic growth in BAV patients in a sma…”
Mahadevia, R., Barker, A. J., Schnell, S., Entezari, P., Kansal, P., Fedak, P. W. M., Malaisrie, S. C., McCarthy, P., Collins, J., Carr, J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.003026 · Cited by 413
Self-citationBissell, M. M., Hess, A. T., Biasiolli, L., Glaze, S. J., Loudon, M., Pitcher, A., Davis, A., Prendergast, B., Markl, M., Barker, A. J., et al. (2013) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.113.000528 · Cited by 380
Self-citationMulti-modality imaging in aortic stenosis: an EACVI clinical consensus document
Dweck, M. R., Loganath, K., Bing, R., Treibel, T. A., McCann, G. P., Newby, D. E., Leipsic, J., Fraccaro, C., Paolisso, P., Cosyns, B., et al. (2023) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jead153 · Cited by 79
Metadata
- Authors
- Meierhofer, C., Schneider, E. P., Lyko, C., Hutter, A., Martinoff, S., Markl, M., Hager, A., Hess, J., Stern, H., & Fratz, S.
- Venue
- European Heart Journal - Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-12-09
- Volume
- 14
- Issue
- 8
- Pages
- 797-804
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W2165286970
- Cited by
- 166
- References
- 33
- FWCI
- 7.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.