Scalable screening for structural heart disease: promises from artificial intelligence-electrocardiogram tools
Open accessAbstract
This editorial refers to ‘Development and Multinational Validation of an Ensemble Deep Learning Algorithm for Detecting and Predicting Structural Heart Disease Using Noisy Single-lead Electrocardiograms’, by A. Aminorroaya et al., https://doi:10.1093/ehjdh/ztaf034. The global burden of structural heart diseases (SHDs) is escalating over the last decade due to the aging population, where chronic exposure to cardiovascular risk factors (such as hypertension) is partly accountable for driving this increase.1 Early detection of SHD could provide a window of opportunity for timely prevention interventions.2 Indeed, ∼1 in 20 adults aged over 45 years have asymptomatic left ventricular systolic dysfunction (LVSD),3 1 in 10 adults aged 65 or older have moderate/severe valvular heart disease (VHD),4 and 1 in 5 hypertensive individuals have left ventricular hypertrophy (LVH), conditions that are largely preventable.5 There is a need for a scalable and easily accessible tool to facilitate more targeted screening, guide downstream investigations and enable the timely deployment of therapeutic measures to modify the natural history of the disease. The advent of artificial intelligence (AI)-assisted analysis of medical data is revolutionizing all areas of cardiovascular medicine,6 from risk prediction7,8 to the interpretation of medical images7 or electrocardiograms (ECGs).9 There is a plethora of AI-ECG tools capable of detecting a wide range of SHDs, such as LVSD, hypertrophic cardiomyopathy, amyloidosis and mitral valve prolapse.10 Nevertheless, most AI-ECG tools are based on 12-lead ECG, which may not always be readily available in community settings. This limitation provides the rationale for adapting artificial intelligence models to noisy single-lead or wearable electrocardiogram devices, thereby potentially broadening the scope of SHD screening to larger populations. Artificial intelligence tools utilizing single-lead ECG have previously shown to be useful in detecting severe LVSD and predicting the onset of heart failure before the manifestation of clinical symptoms.11 In this issue of the EHJ Digital Health, Aminorroaya et al.12 developed an ensemble of AI-ECG algorithms to detect a broad range of SHDs. Using over 99 000 paired transthoracic echocardiograms and images of single-lead ECG, convolutional neural networks (CNNs) were trained to detect the presence of six SHD conditions, respectively, including LVSD, moderate or severe left-sided valvular disease, moderate or severe aortic regurgitation, moderate or severe aortic stenosis, moderate or severe mitral regurgitation, and severe LVH. The outputs of these CNNs were then integrated with the patient’s age and sex into a deep-learning model, named ADAPT-HEART, to predict cross-sectional SHD. Notably, the ADAPT-HEART model demonstrated good performance in external validation cohorts, comprising a clinically and demographically diverse population drawn from four community hospitals in the USA (a total of ∼44 000 patients) and a population Cohort in Brazil (ELSA-Brazil). The model achieved an excellent area under curve of >0.85 in predicting cross-sectional SHDs.12 Furthermore, the model’s value in predicting incident SHD was evaluated in an additional UK Biobank cohort. This further demonstrates the model’s robustness and generalizability in ethnically diverse populations, which is an important aspect considering the widely recognized racial variations in ECG patterns. The present study enables the possibility of opportunistic screening using a single-lead ECG for detecting a range of SHDs. This has the potential to enhance accessibility, particularly in community settings where clinical ECG measurements may not be readily available. However, questions remain about the utility of this AI-ECG model across different hardware platforms. The quality of the ‘single-lead’ ECG extracted from lead I of the 12-lead ECGs in this study may vary significantly from the noisy ECG waveform obtained from peripheral devices, which are often affected by muscle artefacts and impedance from dry skin contact.13 Although the authors have introduced artificial noise to adapt some of the expected artefacts, it is unclear whether it truly reflects the different types and magnitudes of noise in real-world ECG peripheral devices.13 Furthermore, denoising algorithms are often applied to raw ECG waveforms from mobile devices to varying intensities, which profoundly alter the signal-to-noise ratio and interpretability.14 This underscores the complexity of vendor-specific hardware platforms, and the need for comprehensive prospective validation of the current AI-ECG tools using real-world single-lead ECG data from a variety of wearable devices before large-scale deployment for SHD screening in the community.15 The involvement of industry at this stage is essential, as it can serve as a vehicle for transforming these algorithms into usable applications integrated into hardware. The safety and
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Current evidence most strongly supports AI-ECG for low-LVEF detection, where pragmatic randomized implementation and early economic data are available.
“Current evidence most strongly supports low-LVEF detection, where pragmatic randomized implementation and early economic data are available.”
From AI-ECG for Echocardiography Triage in Structural Heart Disease: Evidence, Implementation, and Future Directions (2026) · cites this paper as [13]
The Introduction reports AI-ECG detection of left ventricular systolic dysfunction, and the Discussion notes that detecting it can trigger established care pathways. The paper does not report pragmatic randomized implementation evidence or early economic data; its Discussion instead calls for further cost-effectiveness analysis. The stronger comparative claim that evidence most supports low-LVEF detection is not established by these passages. No page numbers are available in our copy. (LLM, conf=0.84)
Experimental — accuracy not yet measuredThe EAGLE trial found that an AI-ECG alert embedded in routine primary care increased new low-EF diagnosis from 1.6% to 2.1% (OR 1.32; P = 0.007).
“New low-EF diagnosis increased from 1.6% to 2.1%; OR 1.32; P = 0.007”
From AI-ECG for Echocardiography Triage in Structural Heart Disease: Evidence, Implementation, and Future Directions (2026) · cites this paper as [13]
The Introduction discusses AI-ECG detection of structural heart disease, and the Discussion considers possible community screening, but neither reports an EAGLE trial or a primary-care alert. Searches for EAGLE, new low-EF diagnosis, and the stated percentages, odds ratio, and P value found no passage supporting the claimed result. (LLM, conf=0.75)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Global Burden of Cardiovascular Diseases and Risk Factors, 1990–2019
Roth, G. A., Mensah, G. A., Johnson, C. O., Addolorato, G., Ammirati, E., Baddour, L. M., Barengo, N. C., Beaton, A. Z., Benjamin, E. J., Benziger, C. P., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.010 · Cited by 11,449 · see citing works
Burden of Systolic and Diastolic Ventricular Dysfunction in the Community
Redfield, M. M., Jacobsen, S. J., Burnett, J. C. J., Mahoney, D. W., Bailey, K. R., & Rodeheffer, R. J. (2003) · JAMA · doi:10.1001/jama.289.2.194 · Cited by 2,989 · see citing works
Artificial intelligence-enhanced electrocardiography in cardiovascular disease management
Siontis, K. C., Noseworthy, P. A., Attia, Z. I., & Friedman, P. A. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00503-2 · Cited by 914 · see citing works
d'Arcy, J. L., Coffey, S., Loudon, M. A., Kennedy, A., Pearson-Stuttard, J., Birks, J., Frangou, E., Farmer, A. J., Mant, D., Wilson, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw229 · Cited by 724 · see citing works
Chan, K., Wahome, E., Tsiachristas, A., Antonopoulos, A. S., Patel, P., Lyasheva, M., Kingham, L., West, H. W., Oikonomou, E. K., Volpe, L., et al. (2024) · The Lancet · doi:10.1016/s0140-6736(24)00596-8 · Cited by 309 · see citing works
Self-citationLeft Ventricular Hypertrophy and Clinical Outcomes in Hypertensive Patients
Ruilope, L. M., & Schmieder, R. E. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2008.16 · Cited by 259 · see citing works
Liu, T., Krentz, A., Lu, L., & Curcin, V. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztae080 · Cited by 177 · see citing works
Artificial intelligence in cardiovascular medicine: clinical applications
Lüscher, T. F., Wenzl, F. A., D’Ascenzo, F., Friedman, P. A., & Antoniades, C. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae465 · Cited by 160 · see citing works
Self-citationKhunte, A., Sangha, V., Oikonomou, E. K., Dhingra, L. S., Aminorroaya, A., Mortazavi, B. J., Coppi, A., Brandt, C. A., Krumholz, H. M., & Khera, R. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00869-w · Cited by 95 · see citing works
Dhingra, L. S., Aminorroaya, A., Sangha, V., Pedroso, A. F., Asselbergs, F. W., Brant, L. C. C., Barreto, S. M., Ribeiro, A. L. P., Krumholz, H. M., Oikonomou, E. K., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehae914 · Cited by 64 · see citing works
Chambers, J. B., Garbi, M., Nieman, K., Myerson, S. G., Piérard, L., Habib, G., Zamorano, J. L., Edvardsen, T., Lancellotti, P., Delgado, V., et al. (2016) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jew309 · Cited by 62 · see citing works
Aminorroaya, A., Dhingra, L. S., Pedroso, A. F., Shankar, S. V., Coppi, A. C., Khunte, A., Foppa, M., Brant, L. C., Barreto, S. M., Ribeiro, A. L. P., et al. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaf034 · Cited by 29 · see citing works
Lim, J., Lee, H. S., Han, G. I., Kang, S., Jang, J.-H., Jo, Y., Son, J. M., Lee, M. S., Kwon, J., & Lee, S. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaf025 · Cited by 16 · see citing works
Using artificial intelligence to spot heart failure from ECGs: is it prime time?
Antoniades, C. A., & Chan, K. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehae906 · Cited by 8 · see citing works
Self-citationMcKenna, S., McCord, N., Diven, J., Fitzpatrick, M. P., Easlea, H., Gibbs, A., & Mitchell, A. R. J. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztae063 · Cited by 7 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Tang, Q., Deng, K., Cui, Y., Liu, H., & Qian, B. (2026) · International Journal of General Medicine · doi:10.2147/ijgm.s610298
“13,14,37,38 For safety-net use, model performance should therefore be judged by the balance among sensitivity, positive predictive value, referral burden, and follow-up completion, rather than by discrimination alone.”
- Authors
- Antoniades, C., & Chan, K.
- Affiliations
- British Heart Foundation (GB)
- Corresponding author
- Antoniades, Charalambos
- Venue
- European Heart Journal - Digital Health
- Publisher
- Oxford University Press (OUP)
- Published
- 2025-05-27
- Volume
- 6
- Issue
- 4
- Pages
- 521-523
- ISSN
- 2634-3916 (ISSN-L)
- PMC
- PMC12282378
- OpenAlex
- W4410735043
- Cited by
- 1
- References
- 15
- Citations by year
- 2026: 1
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- European Heart Journal - Digital Health (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- British Heart Foundation (CH/F/21/90009, TG/19/2/34831, RG/F/21/110040, FS/CRTF/24/24704)
- Innovate UK (104472)
- Industry Strategy Challenge Fund (104688)
- EU Research
- Innovation Action MAESTRIA (965286)
- NIHR Oxford Biomedical Research Centre
- Oxford British Heart Foundation Oxford Centre of Research Excellence
- British Atherosclerosis Society
- Amarin
- Covance
- Silence Therapeutics
- AMGEN
- Abcentra
- Nodthera
- Novartis
- Elli Lilly
- Sanofi
- Novo Nordisk
- Astra Zeneca
- Lexicon
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- structural heart disease, single-lead ECG, wearable ECG, left ventricular systolic dysfunction, valvular heart disease, left ventricular hypertrophy, hypertrophic cardiomyopathy, mitral valve prolapse, amyloidosis, ensemble deep learning, convolutional neural networks, transthoracic echocardiography, screening, early detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review