CoChat

Severe aortic stenosis detection by deep learning applied to echocardiography

Open access
Holste, Gregory, Oikonomou, Evangelos K, Mortazavi, Bobak J, Coppi, Andreas, Faridi, Kamil F, Miller, Edward J, Forrest, John K, McNamara, Robert L, Ohno-Machado, Lucila, Yuan, Neal, Gupta, Aakriti, Ouyang, David, Krumholz, Harlan M, Wang, Zhangyang, Khera, Rohan · 2023 · European Heart Journal
Cited by 147

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

Background and Aims: Early diagnosis of aortic stenosis (AS) is critical to prevent morbidity and mortality but requires skilled examination with Doppler imaging. This study reports the development and validation of a novel deep learning model that relies on two-dimensional (2D) parasternal long axis videos from transthoracic echocardiography without Doppler imaging to identify severe AS, suitable for point-of-care ultrasonography. Methods and results: In a training set of 5257 studies (17 570 videos) from 2016 to 2020 [Yale-New Haven Hospital (YNHH), Connecticut], an ensemble of three-dimensional convolutional neural networks was developed to detect severe AS, leveraging self-supervised contrastive pretraining for label-efficient model development. This deep learning model was validated in a temporally distinct set of 2040 consecutive studies from 2021 from YNHH as well as two geographically distinct cohorts of 4226 and 3072 studies, from California and other hospitals in New England, respectively. The deep learning model achieved an area under the receiver operating characteristic curve (AUROC) of 0.978 (95% CI: 0.966, 0.988) for detecting severe AS in the temporally distinct test set, maintaining its diagnostic performance in geographically distinct cohorts [0.952 AUROC (95% CI: 0.941, 0.963) in California and 0.942 AUROC (95% CI: 0.909, 0.966) in New England]. The model was interpretable with saliency maps identifying the aortic valve, mitral annulus, and left atrium as the predictive regions. Among non-severe AS cases, predicted probabilities were associated with worse quantitative metrics of AS suggesting an association with various stages of AS severity. Conclusion: This study developed and externally validated an automated approach for severe AS detection using single-view 2D echocardiography, with potential utility for point-of-care screening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehad456

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 147

Metadata

Authors
Holste, G., Oikonomou, E. K., Mortazavi, B. J., Coppi, A., Faridi, K. F., Miller, E. J., Forrest, J. K., McNamara, R. L., Ohno-Machado, L., Yuan, N., Gupta, A., Ouyang, D., Krumholz, H. M., Wang, Z., & Khera, R.
Venue
European Heart Journal
Published
2023-08-23
Volume
44
Issue
43
Pages
4592-4604
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W4386090740
Cited by
147
References
22
FWCI
5.09
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Severe aortic stenosis detection by deep learning applied to echocardiography. https://app.cochat.ai/papers/10.1093/eurheartj/ehad456
The paper
Holste, G., Oikonomou, E. K., Mortazavi, B. J., Coppi, A., Faridi, K. F., Miller, E. J., Forrest, J. K., McNamara, R. L., Ohno-Machado, L., Yuan, N., Gupta, A., Ouyang, D., Krumholz, H. M., Wang, Z., & Khera, R. (2023). Severe aortic stenosis detection by deep learning applied to echocardiography. European Heart Journal. https://doi.org/10.1093/eurheartj/ehad456

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.